Glastender MFV48 User Manual

Operation Manual, Parts Directory, and Price List
A Family Company Manufacturing
In The USA Since 1969
Front Venting SelF-Contained CoolerS
and
FV24, FV48 MFV24, MFV48
Mug FroSterS
24
48
This manual applies to FV and MFV models manufactured in 2013 and after. See
page 1 for specic model release information. For FV and MFV models manufactured
prior, please see Vertical Door Coolers Operation Manual and Parts Directory.
Glastender, Inc. · 5400 North Michigan Road · Saginaw, MI · 48604-9780
800.748.0423 · 989.752.4275 · Fax 989.752.4444 · www.glastender.com
© 2012 Glastender, Inc.
index
Model eFFectiVe dates ....................................................................................... 1
digital controller operation ........................................................................... 2
terMs and conditions ......................................................................................... 3
Warranty ............................................................................................................. 4
installation
Introduction ..................................................................................................... 5
Utility Requirements and Connections ........................................................... 5
Uncrating and Start-Up Instructions ............................................................... 5
Operation ......................................................................................................... 5
Cleaning Instructions ..................................................................................5 - 6
Floor Sealing Instructions ............................................................................... 6
Cooler Installation Checklist ........................................................................... 7
speciFications
Electrical and Refrigeration Specifications ..................................................... 7
FV Wiring Diagram ......................................................................................... 8
MFV Wiring Diagram ..................................................................................... 9
replaceMent parts
Interior Parts .................................................................................................. 10
Condensor and Evaporator Parts ............................................................ 11 - 12
Doors and Related Parts ......................................................................... 13 - 14
Shelving, Racks, and Related Parts ............................................................... 15
Grills .............................................................................................................. 16
220 Condensor and Evaporator Parts ............................................................ 17
220 Doors and Related Parts ......................................................................... 17
Model eFFeCtiVe Sn and dateS
This manual is specic to self-contained FV24, FV48, MFV24, and MFV48 coolers manufactured per
information below.
FV24 SN 134142753F and SN 134143411F / SN 134143788F manufactured 05-13-2013 and beyond FV48 SN 134142796F / SN 134143788F manufactured 05-13-2013 and beyond MFV24 SN 404144876N manufactured 07-10-2013 and beyond MFV48 SN’s after 404144876N and manufactured date of 07-10-2013
Glastender, Inc. • 5400 North Michigan Road • Saginaw, MI • 48604-9780
1
800.748.0423 • 989.752.4275 • Fax 989.752.4444 • www.glastender.com
digital Controller operation
The operating temperature range is preset at the factory according to the table below and can be adjusted up or down within the limits shown.
To see the set point - push and immediately release the SET button. The set point will be displayed.
To return to normal visualization - Push and
immediately release the SET button or wait ve
seconds.
Factory Settings Range of Adjustment
Set Point Operating Range† Minimum Set Point Maximum Set Point
Standard Cooler Setting
B = Beer
W = White Wine
R = Red Wine
MFV Setting
Adjusting the factory set point will also adjust the operating range by the same amount.
34°F 34°F to 39°F 33°F 35°F
34°F 34°F to 39°F 33°F 35°F
50°F 50°F to 55°F 45°F 55°F
60°F 60°F to 65°F 55°F 65°F
10º F 10º F to 15º F 0º F 30º F
To change the set point - push and hold the SET button for more than two seconds. When the º F
display begins ashing, push the up arrow or down
arrow buttons to adjust the set point to the desired value.
To save the new set point and return to the tem­perature display mode - push and release the SET
button or wait ten seconds.
The refrigerator is programmed to automatically defrost four times daily for approximately twenty minutes. During defrost, the fan inside the cooler will remain on and the refrigeration system will turn off. To initiate defrost manually, push and hold the DEFROST button for more than two seconds.
The thermostat controller does not have an “OFF” function. To turn refrigerator off, the unit must be unplugged or power to the electrical branch circuit has to be turned off via a circuit breaker or switch.
Models BB, ND, LP, FV, MFV, UCR Self Contained Coolers using Dixell digital thermostat controller
The thermostat control probe wire connector may become disconnected when the compressor compartment cover and/or grill are removed. This will result in thermostat P1 code. While the P1 code is
ashing the compressor will cycle 5 minutes on and 5
minutes off and may cause icing of the evaporator coil. Service calls to reconnect the probe wiring are not covered by factory warranty.
Probe wire connector
Glastender, Inc. • 5400 North Michigan Road • Saginaw, MI • 48604-9780
Glastender, Inc. • 5400 North Michigan Road • Saginaw, MI • 48604-9780
800.748.0423 • 989.752.4275 • Fax 989.752.4444 • www.glastender.com
800.748.0423 • 989.752.4275 • Fax 989.752.4444 • www.glastender.com
2
terMS and ConditionS
priCeS:
All prices are LIST. Applicable taxes will be added.
QuotationS:
Unless otherwise stated, quotations are effective for 30 days only.
aCCeptanCe:
All orders are subject to acceptance by Glastender, Inc.’s headquarters in Saginaw, Michigan. Possession of the Product Directory and Price List is not an offer to sell.
ShipMentS:
F.O.B. factory in Saginaw, Michigan. Freight terms are Third Party or Collect if shipped directly to you. Prepay and Add to Invoice freight terms are available upon request. The approximate shipping weights of all products are listed with the prices. Partial shipments will be made unless otherwise specified by the customer. Surface freight classifica­tions are: Glasswashers, Line Chillers - Class 92.5 Cocktail Stations, Underbar Equipment - Class 85 Bar Die/Underbar Equipment – Class 125 Refrigeration Equipment, 48” long or smaller - Class 100 Refrigeration Equipment, greater than 48” long - Class 110
All small items are evaluated to see the most cost effective means for shipment. Many small items ship via UPS or FedEx; however, when dimensional weight is excessive DB Schenker, UPS Supply Chain, or even common LTL carriers are the most cost effective choice. Spare parts orders received before 1:00 PM EST can usually be shipped the same day.
deliVery:
The majority of equipment is manufactured to order and typically ships within three to six weeks after complete order information is received by the factory. In-stock equipment typically ships within two to three days of the factory receiving complete order information.
returnS:
Items specified as “Manufactured to Order” are NOT returnable.
A Return Material Authorization (RMA) number must be issued by the factory in advance for any items that are returnable. The RMA number MUST be noted on the outside of the returned package. Returns must be received within 90 days of the RMA issue date. Shipping charges must be prepaid. A minimum 20% restocking charge will be applied to all authorized returns if received in new, unused condition in the original packaging.
The above conditions apply to spare part returns, except spare part returns must be received within 30 days of original shipment for elec­tronic or electrical parts or within 90 days for all other parts.
loSS or daMage:
For customer routed shipments, Glastender, Inc. is not responsible for any loss, damage, or delay of merchandise during shipment. Such transit claims must be filed with the carrier. Merchandise must be examined on arrival. If shortages occur, Glastender, Inc. must be notified in writing within five (5) days of delivery to honor any shortage claim. Glastender will assume responsibility for freight claims on Prepay and Add ship­ments but the customer must inspect freight and note any damage upon receipt. Failure to do so may result in losses at the customer’s expense.
The order department is happy to assist with routing or shipping ques­tions.
payMent terMS:
Cash should be included with all orders unless credit terms have been arranged. To establish credit, banking and trade references are required. A convenient credit application is available upon request. Payment via credit card is not our normal means of receiving payment. Visa and MasterCard will be accepted, but must be charged at the time of ship­ment. In addition, a payment via credit card for orders totaling more than $500 will incur a 3% convenience fee on the total transaction amount.
CuStoM orderS:
Custom orders must be paid in advance and are not subject to cancel­lation.
laMinateS:
Some products include common, readily available plastic laminates of the customer’s selection. There may be an additional charge if uncom­mon varieties are ordered.
05/18/10
Glastender, Inc. • 5400 North Michigan Road • Saginaw, MI • 48604-9780
3
800.748.0423 • 989.752.4275 • Fax 989.752.4444 • www.glastender.com
Warranty StateMent
APPLICABLE TO ALL PRODUCTS SOLD WITHIN THE UNITED STATES AND CANADA
LABOR: Glastender, Inc. warrants all products to be free of defects in material and workmanship. In established areas, a start-up is included with glasswasher models GT-24 and GT-30. A 1-year labor warranty applies to all glasswashers. BDS model bottle disintegration systems and self-contained refrigeration models, except beer line chillers, include a 1-year labor warranty, for the duration of one year from date of installation or up to 18 months from date of factory shipment, whichever occurs sooner. For warranty labor claims beyond 15 months from the date of factory shipment, proof of date of installation or occupancy must be provided. Authorization for labor must be obtained from Glastender within the warranty period and prior to the service being performed. Labor warranty applies to the United States and Canada only.
PARTS: Within one year from date of installation or 18 months from date of factory shipment, whichever occurs sooner, Glastender, Inc. will replace any part or assembly found defective under normal use and service. Field replacement parts include a warranty of 90 days from date of installation.
FOUR YEAR ADDITIONAL COMPRESSOR WARRANTY: Glastender will warrant to the original user the compressor for all self­contained refrigeration models for an additional four years following the regular one-year warranty period. This plan applies to the compressor only.
A warranty claim form MUST accompany all returned defective parts or assemblies. This form MUST be completed in full. Failure to do so may result in delay or denial of credit. Any defective part or assembly must be returned to Glastender, Inc., Saginaw, Michigan, with all transporta­tion and delivery charges prepaid. Warranty repairs or replacements will be shipped FOB factory in Saginaw, Michigan. Reimbursement for applicable freight charges covers ground service only.
Glastender provides in-warranty repairs during a service company’s regular working days and hours. There is no provision for payment of a premium rate during “overtime” hours. When warranty service is requested during other than normal working hours, the end user will be charged the premium portion of the overtime rate.
The warranty covers substantiated travel expenses for up to 2 hours / 100 miles round trip and a maximum of $150. Any additional costs due to installations that require extra work, time, or travel to gain access for service are the sole responsibility of the equipment purchaser. Any exceptions to these travel and access limitations must be pre-approved by a factory representative.
The warranty does not cover equipment subjected to accidents, freight damage, alterations from the original design, improper power and/or plumbing hookups, improper chemical use, general misuse, or lack of routine required maintenance as determined by Glastender, Inc. Installation, normal control adjustments, general maintenance, correct­ing an installation error, or service calls that reveal the unit is function­ing normally will not be reimbursed under warranty.
Condenser coils on self-contained refrigeration products must be cleaned regularly. Failure to provide adequate air flow to a refrigeration unit will void the warranty.
Glastender shall not be liable for loss of use, revenue, or profit, or for any other indirect, incidental, special, or consequential damage includ­ing, but not limited to, product spoilage or loss.
This warranty is conditioned upon Glastender receiving notice of any defect subject to this warranty within sixty (60) days of its discovery by the end user or dealer. All products are warranted only for the initial place of installation. Removal of a product automatically terminates this warranty.
SECOND YEAR EXTENDED PARTS & LABOR WARRANTY:
Glastender’s one-year parts and labor warranty on self-contained refrig­eration units, excluding beer line chillers, can be extended to two years with the purchase of a two year parts and labor warranty. Specify part number EWR2 ($150 net price) when ordering.
EXPORT WARRANTY - One year parts only.
EXCLUSION OF WARRANTIES
EXCEPT AS PROVIDED ABOVE, GLASTENDER MAKES NO WARRANTIES, EXPRESS OR IMPLIED, INCLUDING, BUT NOT LIMITED TO, ANY IMPLIED WARRANTY OF MERCHANTABILITY, FITNESS FOR A PARTICULAR PURPOSE OR NON-INFRINGEMENT.
LIMITATION OF REMEDIES AND DAMAGES If Buyer makes a valid and timely claim as outlined above, Glastender’s liability and Buyer’s remedies under this agreement will be limited solely to labor charges authorized and/or replacement or credit, at Glastender’s option, with respect to Products returned at Buyer’s expense within thir­ty (30) days after warranty repair. GLASTENDER’S LIABILITY WILL IN NO EVENT BE GREATER IN AMOUNT THAN THE PURCHASE PRICE OF THE RETURNED PRODUCTS. GLASTENDER WILL NOT BE LIABLE UNDER ANY CIRCUMSTANCE FOR CONSEQUENTIAL OR INCIDENTAL DAMAGES, INCLUDING, BUT NOT LIMITED TO, LABOR COSTS EXCEPT AS COVERED UNDER OUR WARRANTY, LOST PROFITS OR THE LOSS OF PERISHABLE PRODUCTS RESULTING FROM THE USE OF OR INABILITY TO USE OUR PRODUCTS OR FROM OUR PRODUCTS’ INCORPORATION INTO OR BECOMING A COMPONENT OF ANY OTHER PRODUCT. NEITHER PARTY WILL HAVE ANY NEGLIGENCE OR OTHER TORT LIABILITY TO THE OTHER, OR TO ANY THIRD PARTY, ARISING FROM ANY BREACH OF THIS AGREEMENT.
GOVERNING LAW - JURISDICTION
The terms and conditions of an order are to be governed and construed according to the laws of the State of Michigan, without regard to conflict of laws principles. Buyer hereby consents to the jurisdiction and venue of the courts located in Saginaw County, Michigan.
No representative, distributor, dealer, or any other person is authorized to modify this warranty. This warranty replaces all other written or verbal warranties.
NOTE: Glastender, Inc.’s policy of constant quality improvement means that prices, specifications, and policies are subject to change without notice. Questions regarding this warranty should be directed to Glastender’s Customer Service Representative.
03-21-14
IMPORTANT!!
Attention Refrigeration Service Companies
Please review the important warranty information on this page. If you believe a service call should be covered by the factory, please call the factory for authorization between 8AM and 5PM EST, Monday through Friday.
Glastender, Inc. • 5400 North Michigan Road • Saginaw, MI • 48604-9780
800.748.0423 • 989.752.4275 • Fax 989.752.4444 • www.glastender.com
4
inStallation
introduCtion
This manual describes the operational features of Front Vent Coolers and Mug Frosters. Please review this information before attempting installation and operation.
Long term, trouble-free service will follow if good housekeeping and maintenance procedures are followed. Thank you for selecting Glastender, Inc. products.
utility reQuireMentS and ConneCtionS
Electrical: 115 Volt AC, 1 Phase, 60 Hz. A separate 15 Amp circuit is recommended. A 10-foot grounded cord and plug is included with self-contained models.
Plumbing:
unCrating and Start-up inStruCtionS
All models are shipped in one carton. These steps should be followed:
1. If legs or casters are included, bolt them to the base with the bolts provided.
2. Unwrap power cord from base if included.
3. Position unit and level and/or seal as required (see page 6).
4. Place shelves in desired location.
5. Plug into 115 volt AC outlet if a power cord is included.
6. Load FV with bottles or cans or load MFV with glassware and allow time for products/glassware to cool.
7. Your Glastender equipment is now ready for use.
Automatic condensate evaporator is included. No drain connection required.
operation
The operating temperature range varies. See digital thermostat instructions.
Self-contained models include an automatic defrost system. The refrigerator will defrost every six hours for approximately 20 minutes. Endwall coolers will defrost every four hours for approximately 15 minutes. During the defrost, the fan inside the cooler will remain on and the refrigeration system will turn off
Cleaning inStruCtionS
Cleaning is essential to sustaining the integrity of your equipment and preventing corrosion.
ESTIMATED CLEANING TIME: 5 to 10 minutes per unit daily, 45 minutes quarterly
FREQUENCY: Daily cleaning of exterior & door gaskets. Quarterly cleaning of interior, including shelves.
PROCEDURE:
1. A non-chlorine based cleaner or mild detergent and warm water applied with a soft cloth or sponge to all contact sur-
faces.
2. Immediately rinse off cleaning agent(s), using clean warm water, clean soft cloth or sponge.
3. Dry with a soft clean cloth, removing standing water as soon as possible.
Cleaning Instructions continued on page 6
Glastender, Inc. • 5400 North Michigan Road • Saginaw, MI • 48604-9780
5
800.748.0423 • 989.752.4275 • Fax 989.752.4444 • www.glastender.com
inStallation
1" BASE
Cleaning Instructions continued from page 5
NOTES:
1. Never use hydrochloric acid, wire brushes, steel wool, scrapers, or chlorine based cleaners on stainless steel surfaces,
since they will break down the passivity layer and allow corrosion to occur.
2. On stainless steel surfaces, you may use a soft bristle brush or Scotch-Brite® pad for more stubborn stains. Always
scrub with the direction of the grain. Follow with a thorough cleaning as described above.
3. Deposits from food preparation must be properly removed. Even hard water deposits will rust stainless steel, if not
removed.
4. Repeated cleaning may dry up black-vinyl-clad steel (exterior) surfaces of the cooler. Armor All® or similar product
can bring back the shine. Apply the product to a cloth and then rub into the surface, rather than spraying it directly onto the black-vinyl-clad surface.
5. The cooler door gaskets are most often overlooked when cleaning. Failure to clean them regularly will lead to prema-
ture failure, since alcohol and moisture build-up breaks down the gasket material.
6. Take care when removing the front grill to clean the compressor compartment as the thermostat control probe wire
connector may become disconnected. See page 2 for complete information.
Sealing VertiCal door Cooler to Floor
To comply with NSF & health codes if the unit is not on legs or casters, the cooler base must be sealed to the floor using NSF listed sealant. Place a bead of sealant along outer edges of the base and remove excess with disposable towel. The floor sealing procedure does not apply to models that include legs or casters.
COOLER DOOR
MAGNETIC GASKET
COOLER CABINET
Side View of Cabinet
FLOOR
BEAD SEALANT
attention inStaller: WARNING!!
Failure to level this cooler WILL VOID THE FACTORY WARRANTY. Doors will not close properly causing damage to hinges, handles, and/or gaskets which will adversely affect the refrigeration systems.
COOLER WITH 6" LEGS
COOLER WITHOUT LEGS
Glastender, Inc. • 5400 North Michigan Road • Saginaw, MI • 48604-9780
800.748.0423 • 989.752.4275 • Fax 989.752.4444 • www.glastender.com
6
inStallation
Cooler inStallation CheCkliSt
Is the unit evenly and solidly supported, either upon legs, or flat on the base; check for high spots?
If the optional legs included, are they attached?
Is the unit level at the base, from end to end?
Do the doors open and close freely, without touching any other part of the unit in travel?
Are there open holes to the outside of the cabinet which are not plugged or insulated?
Are there obstructions of any kind to air flow into or out of the condensing unit?
Is product tubing or are other lines installed in such a manner to not allow shelf access?
eleCtriCal and reFrigeration SpeCiFiCationS
eleCtriCal reFrigerant preSSure p.S.i.g.
FV24 120V, 1 phase, 60 Hz.
2.15 full load amps, 1/10 HP R134a 8.5 oz 220 115
FV48 120v, 1 phase, 60 Hz.
3.25 full load amps, 1/6 HP R134a 9.0 oz 220 115
eleCtriCal reFrigerant preSSure p.S.i.g.
MFV24 120V, 1 phase, 60 Hz.
5.0 full load amps, 1/5 HP R404A 10.0 oz 410 174
MFV48 120v, 1 phase, 60 Hz.
5.5 full load amps, 1/5 HP R404A 10.0 oz 425 174
FV24 and FV48
type Charge high loW
MFV24
and MFV48
type Charge high loW
Glastender, Inc. • 5400 North Michigan Road • Saginaw, MI • 48604-9780
7
800.748.0423 • 989.752.4275 • Fax 989.752.4444 • www.glastender.com
FV Wiring diagraM
Glastender, Inc. • 5400 North Michigan Road • Saginaw, MI • 48604-9780
800.748.0423 • 989.752.4275 • Fax 989.752.4444 • www.glastender.com
8
MFV Wiring diagraM
Black
Green
Receptacle
120V 15A
(-) (+)
White
Black
Green
White
Junction Box
Brown
Green/Yellow
Blue
Optional
Power Supply
120VAC 60HZ 1PH
230VAC 50HZ 1PH
Evaporator Fan
Power Supply
Motor
Blue
Plug
Light
Switch
(+)(-)
Green
12 VDC
Transformer
120/240VAC 50/60HZ
Ribbed Blk
Black
Orange
Terminal Strip
Orange
White
Blue
Red
Black
White
Motor
Condenser Fan
MFV48
Orange
White
Additional Door Heat Element
Orange
Orange
White
Connector
White
White
Door Heat Element
Connector
Unit Varies
Lights Per
White
Green
120V 15A
Black
Blue
Green
White
White
MFV48
Solenoid
Additional Evaporator Fan
Controller
Connector
SR
C
Red
1112 10 9
Black
8 7
Black
46 3 2 1
Blue
Orange
White Black
Overload
Start Capacitor
Start Relay
Compressor
Evaporator/Condenser Unit Lighting
Glastender, Inc. • 5400 North Michigan Road • Saginaw, MI • 48604-9780
9
800.748.0423 • 989.752.4275 • Fax 989.752.4444 • www.glastender.com
interior partS
part no.
1. 06009153 Air chute cover (FV24 & MFV24) 40.00 06009196 Air chute cover, left (FV48 & MFV48) 44.00 06009197 Air chute cover, right (FV48 & MFV48) 45.00
2. 06001409 Receptacle 5.00
3. 06009684 Power supply for LED lightstrip kit 60.00
4. 06001584 Cover, electrical box 1.50
5. 07000607 Power supply bracket 5.00
6. 06009552 LED light kit (Light bar with LED lights, and wire connector)(FV24/MFV24) 55.00 06009553 LED light kit (2 light bars with LED lights, wire, and connector)(FV48/MFV48) 97.00
deSCription
2
4
priCe
6
1
5
3
Glastender, Inc. • 5400 North Michigan Road • Saginaw, MI • 48604-9780
800.748.0423 • 989.752.4275 • Fax 989.752.4444 • www.glastender.com
10
CondenSor and eVaporator partS
part no.
1. 06001385 Filter dryer, 1/4" x 1/4" 20.00
2. 09000308 Valve, schrader, 1/4" x 2-1/2", copper 5.00
3. 06001461 Elbow, white nylon, 1/2" x 1/2" 2.00
4. 06003951 Probe, PVC 5' cable, for use with digital temperature switch 30.00
5. 06009144 Coil cord, 14/3 22.00
6. 06009322 Evaporator fan, 110V, 50-60Hz 80.00
7. 07000768 Drain tube, 1/2" x 2-3/4" 5.00
8. 11000080 Condenser coil 225.00
9. 11000122 Wicking material, drain pan (5 ft.) 15.00
10. 06001445 Condenser fan motor (FV24) 120V, 60Hz, 3 WATT 45.00
10. 06001449 Condenser fan motor (FV48, MFV24, and MFV48) 120V, 60Hz, 6 WATT 100.00
11. 06001395 Condenser fan blade (FV24), white 5.00 07000155 Condenser fan blade (FV48, MFV24, and MFV48) 12.00
12. 07000133 Condenser fan motor bracket (FV24) 20.00 06009202 Condenser fan motor bracket (FV48, MFV24, and MFV48) 10.00
13. 06009105 Condenser fan shroud (FV24) 10.00 06009195 Condenser fan shroud (FV48, MFV24, and MFV48) 10.00
14. 06009106 Condenser fan deector (FV24 and MFV24 only) 20.00
15. 06009143 Evaporator coil (FV24 and MFV24) 125.00 06009203 Evaporator coil (FV48 and MFV48) 140.00
16. 06009101 Evaporator coil shroud (FV24 and MFV24) 24.00 06009194 Evaporator coil shroud (FV48 and MFV48) 28.00
Standard Cooler Temperature Items - FV Models
17. 06008990 Compressor (FV24), 115V, 60Hz 390.00 06009229 Compressor (FV48) 115V, 60Hz 400.00
18. 06009280 Compressor start capacitor (FV24) 115V, 60Hz 21.00 06009284 Compressor start capacitor (FV48) 115V, 60Hz 21.00
19. 06009289 Compressor overload protector (FV24 and FV48) 115V, 60Hz 15.00
20. 06009279 Compressor relay (FV24) 115V, 60Hz 15.00 06009283 Compressor relay (FV48) 115V, 60Hz 15.00
21. 06009200 TXV (FV24 and FV48) 102.00
22. 06003950 Controller (FV24 and FV48) 120V, 60Hz 165.00
Low Temperature Items - MFV Models
07000796 Compressor (MFV24 and MFV48) 115V, 60Hz 470.00 07000800 Compressor start capacitor (MFV24 and MFV48) 115V, 60Hz 21.00 07000799 Compressor overload protector (MFV24 and MFV48) 115V, 60Hz 390.00 07000798 Compressor relay (MFV24 and MFV48) 115V, 60Hz 15.00 06009201 TXV (MFV24 and MFV48) 121.00 07000794 Controller (MFV24 and MFV48) 120V, 60Hz 175.00
23. 06001384 Accumulator (MFV24 and MFV48) 40.00
24. 07000793 Defrost solenoid valve (MFV24 and MFV48), does not include coil 117.60 06001590 Defrost solenoid coil, 120V, 60Hz 63.00
deSCription
priCe
11
Glastender, Inc. • 5400 North Michigan Road • Saginaw, MI • 48604-9780
800.748.0423 • 989.752.4275 • Fax 989.752.4444 • www.glastender.com
CondenSor and eVaporator partS
15
4
5
16
12
3
17
6
21
14
13
11
10
97
1
2
18
22
Glastender, Inc. • 5400 North Michigan Road • Saginaw, MI • 48604-9780
800.748.0423 • 989.752.4275 • Fax 989.752.4444 • www.glastender.com
19
8
20
23
24
12
doorS and related partS
part no.
1. 06001462 Door handle, stainless $60.00 06001653 Door handle, brass 110.00
2. 06001536 Door lock, stainless 36.00 06004009 Key, #806, for stainless cooler door lock (06001536) 4.00 06001535 Door lock, brass 43.00 06004010 Key, #606, for brass cooler door lock (06001535) 4.00 06001677 Plug for door handle, stainless 1.00 06001678 Plug for door handle, brass 1.00 00000067 Screws for top of handle, stainless, 2 required 1.00 00000016 Screws for top of handle, brass, 2 required, 10/32 x 5/8" PFH Machine Screw 1.00 00000258 Screw for bottom of handle, stainless .50
3. 06001372 Hinge set and brackets, 180° swing, left (complete with screws) 35.00
4. 06001373 Hinge set and brackets, 180° swing, right (complete with screws) 35.00
5. 07000356 Lock bracket 10.00
6. 06003713 Cooler door gasket, push-in style, black, 22-1/2" x 23" OD 42.00
7. 00000067 Screw for door hinges (4 required) .50 ea
8. 00000041 Bolts for brackets (6 required) .50 ea
9. 06001485 Plastic washer for hinge 1.00
10. 06001569 Bushing for hinge (gray) 1.00
deSCription
priCe
3
4
2
1
5
6
7
8
10
9
13
Glastender, Inc. • 5400 North Michigan Road • Saginaw, MI • 48604-9780
800.748.0423 • 989.752.4275 • Fax 989.752.4444 • www.glastender.com
doorS and related partS
part no.
1. 06009136 Stainless door (FV/MFV) 358.00 06009137 Black vinyl clad door (FV/MFV) 308.00 06009138 Glass door, stainless (FV) 648.00 06009139 Glass door, black (FV) 598.00 06009415 Laminate door (FV/MFV) 428.00 06009533 Unlaminated door (FV/MFV) 308.00 06009416 Glass door, laminate (FV) 718.00
2. 06009421 Heated glass door, left hinge, 120V, stainless (MFV) 1,082.00 06009422 Heated glass door, left hinge, 120V, black (MFV) 926.00 06009423 Heated glass door, left hinge, 120V, laminate (MFV) 1,058.00 06009448 Heated glass door, right hinge, 120V, stainless (MFV) 1,082.00 06009449 Heated glass door, right hinge, 120V, black (MFV) 926.00 06009450 Heated glass Door, right hinge, 120V, laminate (MFV) 1,058.00 NOTE: Door swings for heated glass doors require matching grill part #’s for wire recep-
deSCription
tacle access. If changing door swings of heated glass doors order appropriate grill from page 16.
priCe
1
2
Glastender, Inc. • 5400 North Michigan Road • Saginaw, MI • 48604-9780
800.748.0423 • 989.752.4275 • Fax 989.752.4444 • www.glastender.com
14
ShelVing, raCkS and related partS
part no.
1. 06004398 Grey coated shelf, 19-1/4" x 17-3/8" (FV24, MFV24) 77.00 06001564 Pilaster 5.00 06001574 Thumbscrew, stainless steel, for pilaster 1.50 06001565 Clip, for pilaster, stainless steel 1.50
2. 06009328 Grey coated shelf, 17-3/8" x 21-9/16", left (FV48, MVF48) 77.00
3. 06009329 Grey coated shelf, 17-3/8” x 21-9/16”, right (FV48, MVF48) 77.00
deSCription
priCe
1
2
3
15
Glastender, Inc. • 5400 North Michigan Road • Saginaw, MI • 48604-9780
800.748.0423 • 989.752.4275 • Fax 989.752.4444 • www.glastender.com
grillS
part no.
1. 06009127 Standard Grill, stainless (FV24/MFV24) 21.00 06009128 Standard Grill, black vinyl (FV24/MFV24) 21.00 06009454 Grill, stainless, heated glass, left hinge (MFV24) 21.00 06009455 Grill, stainless, heated glass, right hinge (MFV24) 21.00 06009456 Grill, black vinyl, heated glass, left hinge (MFV24) 21.00 06009457 Grill, black vinyl, heated glass, right hinge (MFV24) 21.00 06009182 Standard Grill, stainless (FV48/MFV48) 42.00 06009183 Standard Grill, black vinyl (FV48/MFV48) 42.00 06009476 Grill, stainless, heated glass, (LL) (MFV48) 42.00 06009477 Grill, stainless, heated glass, (RR) (MFV48) 42.00 06009478 Grill, stainless, heated glass, (LR) (MFV48) 42.00 06009479 Grill, stainless, heated glass, (RL) (MFV48) 42.00 06009480 Grill, black vinyl, heated glass, (LL) (MFV48) 42.00 06009481 Grill, black vinyl, heated glass, (RR) (MFV48) 42.00 06009482 Grill, black vinyl, heated glass, (LR) (MFV48) 42.00 06009483 Grill, black vinyl, heated glass, (RL) (MFV48) 42.00
deSCription
(RR) right and left door are right hinge (LL) right and left door are left hinge (LR) left door is left hinge, right door is right hinge (RL) left door is right hinge, right door is left hinge
priCe
1
Glastender, Inc. • 5400 North Michigan Road • Saginaw, MI • 48604-9780
800.748.0423 • 989.752.4275 • Fax 989.752.4444 • www.glastender.com
16
220 CondenSor and eVaporator partS
part no.
06001448 Condenser fan motor (FV24), 220V, 50-60Hz 57.00 06001451 Condenser fan motor (FV48, MFV24, and MFV48), 220V, 50-60Hz 125.00
Standard Cooler Temperature Items - FV Models
06009150 Compressor (FV24), 220-240V, 50Hz 390.00 06009278 Compressor (FV48), 220-240V, 50Hz 400.00 06009282 Compressor start capacitor (FV24), 220-240V, 50Hz 21.00 06009286 Compressor start capacitor (FV48), 220-240V, 50Hz 21.00 06009288 Compressor overload protector (FV24), 220-240V, 50Hz 15.00 06009290 Compressor overload protector (FV48), 220-240V, 50Hz 15.00 06009281 Compressor relay (FV24), 220-240V, 50Hz 15.00 06009285 Compressor relay (FV48), 220-240V, 50Hz 15.00 06004232 Controller (FV24 and FV48), 220V, 50Hz 200.00
Low Temperature Items - MFV Models
07000797 Compressor (MFV24 and (MFV48), 220-240V, 50Hz 470.00 07000803 Compressor start capacitor (MFV24 and MFV48), 220-240V, 50Hz 21.00 07000802 Compressor overload protector (MFV24 and MFV48), 220-240V, 50Hz 390.00 07000801 Compressor relay (MFV24 and MFV48), 220-240V, 50Hz 390.00 07000795 Controller (MFV24 and MFV48), 230V 210.00 06003943 Defrost solenoid coil, 208-240V, 50-60Hz 57.00
deSCription
priCe
220 doorS and related partS
part no.
06009424 Heated glass door, left hinge, 220V, stainless (MFV) 1082.00 06009425 Heated glass door, left hinge, 220V, black (MFV) 926.00 06009426 Heated glass door, left hinge, 220V, laminate (MFV) 1058.00 06009451 Heated glass door, right hinge, 220V, stainless (MFV) 1082.00 06009452 Heated glass door, right hinge, 220V, black (MFV) 926.00 06009453 Heated glass Door, right hinge, 220V, laminate (MFV) 1058.00
17
deSCription
Glastender, Inc. • 5400 North Michigan Road • Saginaw, MI • 48604-9780
800.748.0423 • 989.752.4275 • Fax 989.752.4444 • www.glastender.com
priCe
Loading...