All prices are LIST. Applicable taxes will be added.
Quotations:
Unless otherwise stated, quotations are effective for 30 days only.
aCCePtanCe:
All orders are subject to acceptance by Glastender, Inc.’s headquarters in
Saginaw, Michigan. Possession of the Product Directory and Price List
is not an offer to sell.
shiPMents:
F.O.B. factory in Saginaw, Michigan. Freight terms are Third Party or
Collect if shipped directly to you. Prepay and Add to Invoice freight
terms are available upon request. The approximate shipping weights of
all products are listed with the prices. Partial shipments will be made
unless otherwise specified by the customer. Surface freight classifications are:
Glasswashers, Line Chillers - Class 92.5
Cocktail Stations, Underbar Equipment - Class 85
Bar Die/Underbar Equipment – Class 125
Refrigeration Equipment, 48” long or smaller - Class 100
Refrigeration Equipment, greater than 48” long - Class 110
All small items are evaluated to see the most cost effective means for
shipment. Many small items ship via UPS or FedEx; however, when
dimensional weight is excessive DB Schenker, UPS Supply Chain, or
even common LTL carriers are the most cost effective choice. Spare
parts orders received before 1:00 PM EST can usually be shipped the
same day.
delivery:
The majority of equipment is manufactured to order and typically ships
within three to six weeks after complete order information is received by
the factory. In-stock equipment typically ships within two to three days
of the factory receiving complete order information.
returns:
Items specified as “Manufactured to Order” are NOT returnable.
A Return Material Authorization (RMA) number must be issued by the
factory in advance for any items that are returnable. The RMA number
MUST be noted on the outside of the returned package. Returns must be
received within 90 days of the RMA issue date. Shipping charges must
be prepaid. A minimum 20% restocking charge will be applied to all
authorized returns if received in new, unused condition in the original
packaging.
The above conditions apply to spare part returns, except spare part
returns must be received within 30 days of original shipment for electronic or electrical parts or within 90 days for all other parts.
lossor daMage:
For customer routed shipments, Glastender, Inc. is not responsible for
any loss, damage, or delay of merchandise during shipment. Such transit
claims must be filed with the carrier. Merchandise must be examined on
arrival. If shortages occur, Glastender, Inc. must be notified in writing
within five (5) days of delivery to honor any shortage claim. Glastender
will assume responsibility for freight claims on Prepay and Add shipments but the customer must inspect freight and note any damage upon
receipt. Failure to do so may result in losses at the customer’s expense.
The order department is happy to assist with routing or shipping questions.
PayMent terMs:
Cash should be included with all orders unless credit terms have been
arranged. To establish credit, banking and trade references are required.
A convenient credit application is available upon request. Payment via
credit card is not our normal means of receiving payment. Visa and
MasterCard will be accepted, but must be charged at the time of shipment. In addition, a payment via credit card for orders totaling more than
$500 will incur a 3% convenience fee on the total transaction amount.
CustoM orders:
Custom orders must be paid in advance and are not subject to cancellation.
laMinates:
Some products include common, readily available plastic laminates of
the customer’s selection. There may be an additional charge if uncommon varieties are ordered.
05/18/10
Glastender, Inc. • 5400 North Michigan Road • Saginaw, MI • 48604-9780
APPLICABLE TO ALL PRODUCTS SOLD WITHIN THE UNITED STATES AND CANADA
LABOR: Glastender, Inc. warrants all products to be free of defects in
material and workmanship. In established areas, a start-up is included
with glasswasher models GT-24 and GT-30. A 1-year labor warranty
applies to all glasswashers. BDS model bottle disintegration systems
and self-contained refrigeration models, except beer line chillers,
include a 1-year labor warranty, for the duration of one year from date of
installation or up to 18 months from date of factory shipment, whichever
occurs sooner. For warranty labor claims beyond 15 months from the
date of factory shipment, proof of date of installation or occupancy must
be provided. Authorization for labor must be obtained from Glastender
within the warranty period and prior to the service being performed.
Labor warranty applies to the United States and Canada only.
PARTS: Within one year from date of installation or 18 months from
date of factory shipment, whichever occurs sooner, Glastender, Inc.
will replace any part or assembly found defective under normal use and
service. Field replacement parts include a warranty of 90 days from date
of installation.
FOUR YEAR ADDITIONAL COMPRESSOR WARRANTY:
Glastender will warrant to the original user the compressor for all selfcontained refrigeration models for an additional four years following the
regular one-year warranty period. This plan applies to the compressor
only.
A warranty claim form MUST accompany all returned defective parts or
assemblies. This form MUST be completed in full. Failure to do so may
result in delay or denial of credit. Any defective part or assembly must
be returned to Glastender, Inc., Saginaw, Michigan, with all transportation and delivery charges prepaid. Warranty repairs or replacements
will be shipped FOB factory in Saginaw, Michigan. Reimbursement for
applicable freight charges covers ground service only.
Glastender provides in-warranty repairs during a service company’s
regular working days and hours. There is no provision for payment
of a premium rate during “overtime” hours. When warranty service is
requested during other than normal working hours, the end user will be
charged the premium portion of the overtime rate.
The warranty covers substantiated travel expenses for up to 2 hours /
100 miles round trip and a maximum of $150. Any additional costs due
to installations that require extra work, time, or travel to gain access
for service are the sole responsibility of the equipment purchaser. Any
exceptions to these travel and access limitations must be pre-approved
by a factory representative.
The warranty does not cover equipment subjected to accidents, freight
damage, alterations from the original design, improper power and/or
plumbing hookups, improper chemical use, general misuse, or lack
of routine required maintenance as determined by Glastender, Inc.
Installation, normal control adjustments, general maintenance, correcting an installation error, or service calls that reveal the unit is functioning normally will not be reimbursed under warranty.
Condenser coils on self-contained refrigeration products must be
cleaned regularly. Failure to provide adequate air flow to a refrigeration
unit will void the warranty.
Glastender shall not be liable for loss of use, revenue, or profit, or for
any other indirect, incidental, special, or consequential damage including, but not limited to, product spoilage or loss.
This warranty is conditioned upon Glastender receiving notice of any
defect subject to this warranty within sixty (60) days of its discovery
by the end user or dealer. All products are warranted only for the initial
place of installation. Removal of a product automatically terminates
this warranty.
SECOND YEAR EXTENDED PARTS & LABOR WARRANTY:
Glastender’s one-year parts and labor warranty on self-contained refrigeration units, excluding beer line chillers, can be extended to two years
with the purchase of a two year parts and labor warranty. Specify part
number EWR2 ($150 net price) when ordering.
EXPORT WARRANTY - One year parts only.
EXCLUSION OF WARRANTIES
EXCEPT AS PROVIDED ABOVE, GLASTENDER MAKES
NO WARRANTIES, EXPRESS OR IMPLIED, INCLUDING,
BUT NOT LIMITED TO, ANY IMPLIED WARRANTY OF
MERCHANTABILITY, FITNESS FOR A PARTICULAR PURPOSE
OR NON-INFRINGEMENT.
LIMITATION OF REMEDIES AND DAMAGES
If Buyer makes a valid and timely claim as outlined above, Glastender’s
liability and Buyer’s remedies under this agreement will be limited solely
to labor charges authorized and/or replacement or credit, at Glastender’s
option, with respect to Products returned at Buyer’s expense within thirty (30) days after warranty repair. GLASTENDER’S LIABILITY WILL
IN NO EVENT BE GREATER IN AMOUNT THAN THE PURCHASE
PRICE OF THE RETURNED PRODUCTS. GLASTENDER
WILL NOT BE LIABLE UNDER ANY CIRCUMSTANCE FOR
CONSEQUENTIAL OR INCIDENTAL DAMAGES, INCLUDING,
BUT NOT LIMITED TO, LABOR COSTS EXCEPT AS COVERED
UNDER OUR WARRANTY, LOST PROFITS OR THE LOSS OF
PERISHABLE PRODUCTS RESULTING FROM THE USE OF OR
INABILITY TO USE OUR PRODUCTS OR FROM OUR PRODUCTS’
INCORPORATION INTO OR BECOMING A COMPONENT OF
ANY OTHER PRODUCT. NEITHER PARTY WILL HAVE ANY
NEGLIGENCE OR OTHER TORT LIABILITY TO THE OTHER, OR
TO ANY THIRD PARTY, ARISING FROM ANY BREACH OF THIS
AGREEMENT.
GOVERNING LAW - JURISDICTION
The terms and conditions of an order are to be governed and construed
according to the laws of the State of Michigan, without regard to conflict
of laws principles. Buyer hereby consents to the jurisdiction and venue
of the courts located in Saginaw County, Michigan.
No representative, distributor, dealer, or any other person is authorized
to modify this warranty. This warranty replaces all other written or
verbal warranties.
NOTE: Glastender, Inc.’s policy of constant quality improvement
means that prices, specifications, and policies are subject to change
without notice. Questions regarding this warranty should be directed to
Glastender’s Customer Service Representative.
03-21-14
IMPORTANT!!
Attention Refrigeration Service Companies
Please review the important warranty information on this page. If you
believe a service call should be covered by the factory, please call
the factory for authorization between 8AM and 5PM EST, Monday
through Friday.
Glastender, Inc. • 5400 North Michigan Road • Saginaw, MI • 48604-9780
This manual describes the operational features of Mug Froster/Plate Chiller models MF24, MF36, and MF48. Please review this
information before attempting installation and operation.
Long term, trouble-free service will follow if good housekeeping and maintenance procedures are followed. Thank you for
selecting Glastender, Inc. products.
utility reQuireMentsand ConneCtions
• Electrical: 120 Volt AC, 1 Phase, 60 Hz, 6.1 Full Load Amps. A separate 15 Amp circuit is recommended. A 6-foot
grounded cord is included.
• Plumbing: None required. Automatic condensate evaporator is included.
unCratingand start-uP instruCtions
All Mug Frosters and Plate Chiller models are shipped in one carton. These steps should be followed:
1. If legs or casters are included, bolt them to the base with the bolts provided.
2. Unwrap power cord from base.
3. Position Mug Froster/Plate Chiller and level and/or seal as required (see page 2).
4. Install shelves.
5. Plug into 120 volt AC outlet.
6. Load with mugs, glasses, plates, etc.
7. Your Glastender Mug Froster/Plate Chiller is now ready for use.
sealing Mug Frosterand Plate Chiller Baseto Floor
To comply with NSF & health codes. The Mug Froster base must be sealed to the floor using NSF listed sealant.
Place a bead of sealant along outer edges of the base and remove excess with disposable towel.
Glastender, Inc. • 5400 North Michigan Road • Saginaw, MI • 48604-9780
The Mug Froster/Plate Chiller is designed to chill mugs, glasses, plates, etc. that will appear “frosted” when removed. The
operating temperature range of 0°F (-18°C) to 35°F (2°C).
The Mug Froster/Plate Chiller should be filled with dry, room-temperature mugs, glasses, plates, etc. to allow maximum
chilling. During business hours, the Mug Froster/Plate Chiller can be loaded with additional dry, room-temperature mugs,
glasses, plates, etc. Allow 30 minutes for chilling.
Defrost instruction for Mug Frosters manufactured prior to 03-03-2014 with SN prior to 404149308:
• The Mug Froster/Plate Chiller includes an automatic defrost system. Defrosting will occur every six hours for
approximately 20 minutes. During the defrost cycle, the fan inside the Mug Froster/Plate Chiller will turn off and a
small amount of mist may appear if the top is opened.
• There is also a manual defrost system controlled by a switch located on the front left bottom of the Mug Froster/Plate
Chiller. This is used when there is ice or snow accumulation inside. An end-of-the-day or weekly schedule can be
established for the activation of this manual defrost cycle.
• When the manual defrost switch is pushed, a light will turn on and the Mug Froster/Plate Chiller will go into a six-hour
defrost. After six hours, the Mug Froster/Plate Chiller will resume normal operation.
• If the manual defrost switch is accidentally pushed, the defrost cycle can be terminated by unplugging the power
cord for three seconds.
Defrost instruction for Mug Frosters manufactured on and after 03-03-2014 with SN 404149308 and after:
Mug Froster Elan Digital Control Operations
Control Display
• Normal Operation- Actual box temperature is displayed and the Power LED is illuminated. The compressor LED
will be illuminated when the compressor is running.
• Defrost Operation- During normal defrost operation, the Setpoint temperature will be displayed and the Defrost
LED will be illuminated. During the Manual 6 hour defrost operation, the 6hr LED and the Defrost LED will be
illuminated. The display will show the time remaining in the 6 hour cycle.
Temp Adjustment
• Setpoint Min. 0 deg F
• Setpoint Max 35 deg F
• Setpoint Default 10 deg F
• Differential +8 deg F
• Changing Setpoint- Press the up or down arrow key to raise or lower the setpoint in 1 degree increments.
• Temp Recall- To recall the temperature set point, press the RCL key one time. The display will show Set for 3
seconds then the setpoint temp for 3 Seconds. The control then returns to actual box temp.
Glastender, Inc. • 5400 North Michigan Road • Saginaw, MI • 48604-9780
• Adaptive Defrost Operation- The control is equipped with an adaptive defrost function which adjusts the interval
between defrost cycles to reach the ideal defrost duration.
• Manual Defrost Initiation- Press the DEF key two times
• Manual 6 hour Defrost- Press the DEF Key one time, release, then hold for three seconds
• Defrost Cancellation- To cancel an active defrost cycle, press the DEF key one time. The display will show CnCL
for 3 seconds then revert to normal operation. The control will only allow 2 defrost cancellations in a row.
Error Codes
• Er01- Air Temp Sensor open or short
• Er02- Evap Temp Sensor Open or Short
• Er03- Failure to reach setpoint temp after 60 min. Control will continue to run until temp is reached
• Er04- Display Key is shorted or stuck down
• Er05- Internal software or checksum error
Cleaning instruCtions
Cleaning is essential to sustaining the integrity of your equipment and preventing corrosion.
ESTIMATED CLEANING TIME: 5 to 10 minutes per unit daily, 30 minutes quarterly
FREQUENCY: Daily cleaning of exterior & door gaskets. Quarterly cleaning of interior, including shelves.
PROCEDURE:
1. A non-chlorine based cleaner or mild detergent and warm water applied with a soft cloth or sponge to all contact
surfaces.
2. Immediately rinse off cleaning agent(s), using clean warm water, clean soft cloth or sponge.
3. Dry with a soft clean cloth, removing standing water as soon as possible.
NOTES:
1. Never use hydrochloric acid, wire brushes, steel wool, scrapers, or chlorine based cleaners on stainless steel surfaces,
since they will break down the passivity layer and allow corrosion to occur.
2. On stainless steel surfaces, you may use a soft bristle brush or Scotch-Brite® pad for more stubborn stains. Always
scrub with the direction of the grain. Follow with a thorough cleaning as described above.
3. Deposits from food preparation must be properly removed. Even hard water deposits will rust stainless steel, if not
removed.
4. Repeated cleaning may dry up black-vinyl-clad steel (exterior) surfaces of the cooler. Armor All® or similar product
can bring back the shine. Apply the product to a cloth and then rub into the surface, rather than spraying it directly onto
the black-vinyl-clad surface.
5. The cooler door gaskets are most often overlooked when cleaning. Failure to clean them regularly will lead to premature
failure, since alcohol and moisture build-up breaks down the gasket material.
6. Mug Frosters manufactured prior to 03-03-2014 with SN prior to 404149308: Mug frosters have a manual defrost
timer switch on the front near the bottom, which will activate a 6-hour defrost cycle. Depressing the switch before you
close for the evening will remove excess frost build-up on the interior liner. This procedure should be done as often as
is necessary. It should also be done the night before the quarterly interior cleaning.
Mug Frosters manufactured on and after 03-03-2014 with SN 404149308 and after - Elan Digital Control: See
Defrost Operation instruction at the top of this page.
Glastender, Inc. • 5400 North Michigan Road • Saginaw, MI • 48604-9780
18. 07000234Wicking material, 11-2.5”x9” pieces, MF36, MF48 (prior to 1998)24.00
19. 07000235Wicking material, 11-2.5”x4” pieces, MF24 (prior to 1998)14.00
20. 06001461Elbow, 1/2"x1/2" plastic barb2.00
06001313Condensing unit power cord (prior to 02/25/2014 SN 404149153)20.00
07000724Capillary tube, 0.049x64" (prior to 01/01/2000)20.00
06001346Capillary tube, 0.036x35" (after 2009)20.00
21. 06001345Tubing, drain, clear plastic, 1/2" ID x 5/8" OD, per foot1.45
20.00
25.00
18.00
15.00
12.00
15.00
400.00
Glastender, Inc. • 5400 North Michigan Road • Saginaw, MI • 48604-9780
1. 07000310Bracket, evaporator fan motor (prior to 03/03/2014 SN 404149308)$14.00
07000823Bracket, evaporator fan motor (after 03/03/2014 SN 404149308)14.00
2. 07000134Temperature control mounting bracket (prior to SN 404104830)10.00
3. 07000153Evaporator fan box back (prior to SN 404104830)24.00
07000362Cover, evaporator back (after SN404104830)24.00
07000822Cover, evaporator back (after 03/03/2014 SN 404149308)24.00
4. 07000380Evaporator coil replacement kit180.00
5. 09000298Fan blade, evaporator, 5 blade5.00
6. 07000621Thermostat, includes knob, plate, and tubing (prior to 03/03/2014 SN
404149308)
7. 07000165Defrost sensor26.00
8. 07000169Defrost heater60.00
9. 06001445Fan motor, evaporator45.00
10. 07000182Cover, front, evaporator, MF24, MF36 (prior to SN 404104830)54.00
07000184Cover, front, evaporator, MF48 (prior to SN 404104830)54.00
07000364Cover, front, evaporator, MF24, MF36, MF48 (prior to 03/03/2014 SN
404149308
07000830Cover, front, evaporator, MF24, MF36, MF48 (after 03/03/2014 SN 404149308)54.00
07000183Cover, bottom, evaporator, MF24, MF36 (prior to SN 404104830N)42.00
07000360Cover, bottom, evaporator, MF24, MF36 (SN 404104830N and after)42.00
07000185Cover, bottom, evaporator, MF48 (prior to SN 404104830N)42.00
07000361Cover, bottom, evaporator, MF48 (SN 404104830N and after)42.00
11. 07000228Evaporator housing (prior to SN 404104830)60.00
07000365Drain pan, evaporator MF24, MF36 (after SN 404104830)60.00
07000366Drain pan, evaporator MF48 (after SN 404104830)60.00
07000186Front, black vinyl-clad, MF24 (prior to 03/03/2014 SN 404149308)$33.00
07000187Front, stainless steel, MF24 (prior to 03/03/2014 SN 404149308)48.00
07000188Front, black vinyl-clad, MF36 (prior to 03/03/2014 SN 404149308)44.00
07000189Front, stainless steel, MF36 (prior to 03/03/2014 SN 404149308)72.00
1. 07000190Front, black vinyl-clad, MF48 (prior to 03/03/2014 SN 404149308)55.00
07000191Front, stainless steel, MF48 (prior to 03/03/2014 SN 404149308)96.00
07000824Front, black vinyl-clad, MF24 digital controller (after 03/03/2014 SN 404149308)33.00
07000825Front, stainless steel, MF24 digital controller (after 03/03/2014 SN 404149308)48.00
07000826Front, black vinyl-clad, MF36 digital controller (after 03/03/2014 SN 404149308)44.00
07000827Front, stainless steel, MF36 digital controller (after 03/03/2014 SN 404149308)72.00
07000828Front, black vinyl-clad, MF48 digital controller (after 03/03/2014 SN 404149308)55.00
07000829Front, stainless steel, MF48 digital controller (after 03/03/2014 SN 404149308)96.00
07000773Back, black vinyl-clad, MF2450.00
07000774Back, stainless steel, MF2480.00
07000775Back, black vinyl-clad, MF3660.00
07000776Back, stainless steel, MF36100.00
2. 07000777Back, black vinyl-clad, MF4850.00
07000778Back, stainless steel, MF4896.00
3. 07000779Side, left, black vinyl-clad, all models50.00
07000780Side, left, stainless steel, all models80.00
4. 07000781Side, right, black vinyl-clad, all models50.00
07000782Side, right, stainless steel, all models80.00
14
Front view
3
Rear view
1
Front view
4
2
Model MF48
Glastender, Inc. • 5400 North Michigan Road • Saginaw, MI • 48604-9780