Job Name
Item Number
:
:
B E V E R A G E S Y S T E M S
LC86
1/2 HP Remote Draft
Beer Line Chiller
LC86 DRAFT-PRO
EATURES
TANDARD
S
Modular lift-out refrigeration system for easy
•
field service
inHigh capacity refrigeration and recirculation for
•
high volume and remote long distance installations
CFC-free R134a refrigerant
•
Light-weight, roto-molded glycol bath with drain
•
•
Polyurethane foamed-in-place insulation
F
NOTE: Clearance of 12”
required around unit for
maximum air flow and
20” overhead clearance for
maintenance
PECIFICATIONS
S
Dimensions
Height - 24.25” (61.6 cm)
•
Width - 26.75” (67.9 cm)
•
Depth - 16.50” (41.9 cm)
•
Electrical
115V, 1 phase, 60 Hz, 16.0 full load amps
•
230V, 1 phase, 50 Hz, 8.0 full load amps
•
Dedicated 20 amp circuit is required
•
Includes a 6-foot grounded cord
•
Refrigeration
•
1/2 HP R134a lift-out high temperature con-
densing unit
Glycol Bath Capacity
14.80 U.S. gallons (56.0 l)
•
Maximum Distance to Taps
72.6 m)
250 ft (
•
16.50”
Circulating Pump
60 gph (227 lph)
•
Circulating Motor
1/3 HP (.25 kW)
•
Shipping Weight
125 lbs (56.7 kg)
•
Operating Weight
243 lbs (110 kg)
•
Shipping Cube
9.5 cu ft (.28 cu m)
•
Options
Additional recirculating pump kit
•
•
4” Adjustable legs (up to 5-1/2”)
24.25”
26.75”
Glastender, Inc. • 5400 North Michigan • Saginaw, MI • 48604-9780
989.752.4275 • 800.748.0423 • Fax 989.752.4444 • www.glastender.com
8.03