Glastender KC84 User Manual

Page 1
Operation Manual, Parts Directory, and Price List
A Family Company Manufacturing
In The USA Since 1969
bb*, ND*, aND KC* CoolerS
BB60, BB84, BB108, ND52, ND72, ND92, KC60, KC84, KC108
bb* & ND* two ZoNe CoolerS
BB60BW, BR, WR, BB84BW, BR, WR, BB108BW, BR, WR, ND52BW, BR, WR, ND72BW, BR, WR, ND92BW, BR, WR
*Cooler Serial Number iNformatioN
This manual is specic to:
Self-contained BB and ND coolers purchased in 2009 and after beginning with the listed serial numbers
and dates below and to the right and prior to 2017 and serial number 134169912
KC coolers per list to the right and prior to 2017 and serial number 134169912
All BB and ND Two Zone Coolers prior to 2017 and serial number 134169912
BB
BB60R BB60L BB84R BB84L BB108R BB108L
134121363F 134121425F 134121457F 134121456F 134121452F 134121226F
AND PRIOR TO 2017 and serial number 134169912
02/26/09 03/03/09 03/04/09 03/04/09 03/04/09 02/17/09
BB60-L1-XSH(LR)
ND
ND52R ND52L ND72R ND72L ND92R ND92L
KC
KC60 KC84 All units with S/N's
KC108 All units prior to
134121519F 134121559F 134121906F 134121475F 134121126F 134122745F
134124073N
beginning with 134
2017 and serial number 134169912
03/09/09 03/11/09 04/08/09 03/11/09 02/09/09 06/10/09
09/21/09
N/A
N/A
ND72-R1-GS(LRL)
Glastender, Inc. · 5400 North Michigan Road · Saginaw, MI · 48604-9780
800.748.0423 · 989.752.4275 · Fax 989.752.4444 · www.glastender.com
Rev. 07-23-18
KC60-R1-SS(LR)
© 2011 Glastender, Inc.
Page 2
iNDex
Cooler Serial Number iNformatioN .......................... CoveR
Digital CoNtroller operatioN ...........................................2
iNStallatioN
Introduction .......................................................................3
Utility Requirements and Connections .............................3
Uncrating and Start-Up Instructions .................................3
Operation ...........................................................................3
Cleaning Instructions .................................................. 3 - 4
Sealing Vertical Door Cooler to Floor Instructions ..........4
Cooler Installation Checklist ............................................5
Beer Tower Installation .....................................................5
SpeCifiCatioNS
Electrical and Refrigeration Specifications ......................6
Wiring Diagrams ...............................................................6
replaCemeNt partS
Compressor and Condenser Related Parts ........................7
Evaporator and Related Parts ...........................................8
Shelving, Racks and Related Parts ...................................8
Doors and Related Parts ............................................. 9-10
Refrigeration Compartment Covers ..................................9
220 Volt Electrical Parts .................................................10
Electrical Components ....................................................10
ServiCe aND partS
Warranty .......................................................................... 11
Terms and Conditions .....................................................12
1
Glastender, Inc. • 5400 North Michigan Road • Saginaw, MI • 48604-9780
800.748.0423 • 989.752.4275 • Fax 989.752.4444 • www.glastender.com
Page 3
Digital CoNtroller operatioN
The operating temperature range is preset at the factory according to the table below and can be adjusted up or down within the limits shown.
To see the set point - push and immediately release the SET button. The set point will be displayed.
To return to normal visualization - Push and immediately release the SET button or wait ve seconds.
Factory Settings Range of Adjustment
Set Point Operating Range† Minimum Set Point Maximum Set Point
Standard Cooler Setting
Two Zone Cooler Settings*
B = Beer
W = White Wine
R = Red Wine
Adjusting the factory set point will also adjust the operating range by the same amount
* To determine a Two Zone Cooler refrigeration conguration, refer to the 2 digits immediately preceding the rst hyphen of the
model number found on the cooler data tag. These 2 digits will always be BW (Beer/White Wine), BR (Beer/Red Wine), or WR (White Wine/Red Wine). Example: MODEL: BB60BR-L1-XS(LR).
34º F 34º F to 39º F 33º F 65º F
34º F 34º F to 39º F 33º F 65º F
50º F 50º F to 55º F 33º F 65º F
60º F 60º F to 65º F 33º F 65º F
To change the set point - push and hold the SET button for more than two seconds. When the º F display begins ashing, push the up arrow or down arrow buttons to adjust the set point to the desired
value.
To save the new set point and return to the tem­perature display mode - push and release the SET
button or wait ten seconds.
The refrigerator is programmed to automatically defrost four times daily for approximately twenty minutes. During defrost, the fan inside the cooler will remain on and the refrigeration system will turn off. To initiate defrost manually, push and hold the DEFROST button for more than two seconds.
The thermostat controller does not have an “OFF” function. To turn refrigerator off, the unit must be unplugged or power to the electrical branch circuit has to be turned off via a circuit breaker or switch.
Models BB, ND, LP, FV, MFV, UCR Self Contained Coolers using Dixell digital thermostat controller
The thermostat control probe wire connector may become disconnected when the compressor compartment cover and/or grill are removed. This will result in thermostat P1 code. While the P1 code is ashing the compressor will cycle 5 minutes on and 5 minutes off and may cause icing of the evaporator coil. Service calls to reconnect the probe wiring are not covered by factory warranty.
Probe wire connector
Glastender, Inc. • 5400 North Michigan Road • Saginaw, MI • 48604-9780
800.748.0423 • 989.752.4275 • Fax 989.752.4444 • www.glastender.com
2
Page 4
iNStallatioN
iNtroDuCtioN
This manual describes the operational features of self-contained BB60, BB84, BB108, ND52, ND72, and ND92 coolers and two zone coolers. Please review this information before attempting installation and operation.
Long term, trouble-free service will follow if good housekeeping and maintenance procedures are followed. Thank you for selecting Glastender, Inc. products.
utility requiremeNtS aND CoNNeCtioNS
Electrical: 115 Volt AC, 1 Phase, 60 Hz. A separate 15 Amp circuit is recommended. A 6-foot grounded cord and plug is included with self-contained models.
Plumbing:
Automatic condensate evaporator is included. No drain connection required.
uNCratiNg aND Start-up iNStruCtioNS
All models are shipped in one carton. These steps should be followed:
1. If legs or casters are included, bolt them to the base with the bolts provided.
2. Unwrap power cord from base if included.
3. Position unit and level and/or seal as required (see page 4 and 5).
4. All units intended for draft beer must be plumbed to an external drain. On self-contained models with draft beer and a factory installed finished top, the beer tower drain pan is plumbed through the cabinet and stubs out in the 3" space below the compressor compartment. Connection to an external drain must be made from that point.
5. Place shelves in desired location.
6. Plug into 115 volt AC outlet.
7. Load with bottles or cans and allow time for products to cool.
8. Your Glastender equipment is now ready for use.
operatioN
The operating temperature range is 34°F (1°C) to 40°F (5°C).
Self-contained models include an automatic defrost system. The refrigerator will defrost four times daily for approximately 20 minutes. During the defrost, the fan inside the cooler will remain on and the refrigeration system will turn off.
CleaNiNg iNStruCtioNS
Cleaning is essential to sustaining the integrity of your equipment and preventing corrosion.
ESTIMATED CLEANING TIME: 5 to 10 minutes per unit daily, 45 minutes quarterly
FREQUENCY: Daily cleaning of exterior & door gaskets. Monthly cleaning of condenser filter. Quarterly cleaning of
interior, including shelves.
(Cleaning Instructions continued on page 4)
3
Glastender, Inc. • 5400 North Michigan Road • Saginaw, MI • 48604-9780
800.748.0423 • 989.752.4275 • Fax 989.752.4444 • www.glastender.com
Page 5
iNStallatioN
COOLER DOOR
COOLER CABINET
1" BASE
BEAD SEALANT
FLOOR
MAGNETIC GASKET
(Cleaning Instructions continued from page 3)
Cleaning condenser lter:
PROCEDURE:
1. A non-chlorine based cleaner or mild detergent and warm water
applied with a soft cloth or sponge to all contact surfaces.
2. Immediately rinse off cleaning agent(s), using clean warm water,
clean soft cloth or sponge.
3. Dry with a soft clean cloth, removing standing water as soon as
possible.
4. Condenser filter - remove small louvered covers only. Do NOT
remove compressor cover panel as thermostat control probe wire will become disconnected and cause operation failure not covered by factory warranty (see page 2).
NOTES:
1. Never use hydrochloric acid, wire brushes, steel wool, scrapers, or
chlorine based cleaners on stainless steel surfaces, since they will break down the passivity layer and allow corrosion to occur.
2. On stainless steel surfaces, you may use a soft bristle brush or Scotch-Brite® pad for more stubborn stains. Always
scrub with the direction of the grain. Follow with a thorough cleaning as described above.
3. Deposits from food preparation must be properly removed. Even hard water deposits will rust stainless steel, if not
removed.
4. Repeated cleaning may dry up black-vinyl-clad steel (exterior) surfaces of the cooler. Armor All® or similar product
can bring back the shine. Apply the product to a cloth and then rub into the surface, rather than spraying it directly onto the black-vinyl-clad surface.
5. The cooler door gaskets are most often overlooked when cleaning. Failure to clean them regularly will lead to prema-
ture failure, since alcohol and moisture build-up breaks down the gasket material.
Do NOT remove compressor panel
Remove small louvered covers only
SealiNg vertiCal Door Cooler to floor
To comply with NSF & health codes, the cooler base must be sealed to the floor using NSF listed sealant. Place a bead of sealant along outer edges of the base and remove excess with disposable towel. The floor sealing procedure does not apply to models that include legs or casters.
Glastender, Inc. • 5400 North Michigan Road • Saginaw, MI • 48604-9780
800.748.0423 • 989.752.4275 • Fax 989.752.4444 • www.glastender.com
Side View of Cabinet
4
Page 6
iNStallatioN
atteNtioN iNStaller: WARNING!!
Failure to level this cooler WILL VOID THE FACTORY WARRANTY. Doors will not close properly causing damage to hinges, handles, and/or gaskets which will adversely affect the refrigeration systems.
COOLER WITH 6" LEGS
Cooler iNStallatioN CheCKliSt
Is the unit evenly and solidly supported, either upon legs, or flat on the base; check for high spots?
COOLER WITHOUT LEGS
If the unit was designed for legs, are they attached?
Is the unit level at the base, from end to end?
Do the doors open and close freely, without touching any other part of the unit in travel?
Are there open holes to the outside of the cabinet which are not plugged or insulated?
Are there obstructions of any kind to air flow into or out of the condensing unit?
Is product tubing or are other lines installed in such a manner to not allow shelf access?
SpeCial iNStruCtioNS for beer tower iNStallatioN
Before you begin:
1. Disassemble the tower into three parts, stiffener, skin, and top plate, by
unscrewing the top two screws.
2. Mount the column stiffener with the provided four 1/4"-20x1-1/2" bolts.
3. Install insulation provided into the bottom of the column stiffener.
4. Place the column skin over the stiffener. Run the beer lines through the
hole at the same time.
5. Install insulation provided into the top of the tower assembly.
6. Mount the column top plate to the column stiffener with the two #10-32x1/2" phillips at head s/s machine
screws provided.
7. Apply a bead of silicone sealant around the perimeter of the column. Use your nger to smooth out the bead.
8. Wash tapping device and faucet with detergent and water. Flush beer tapping device and faucet lines.
top plate
stiffener
skin
5
Glastender, Inc. • 5400 North Michigan Road • Saginaw, MI • 48604-9780
800.748.0423 • 989.752.4275 • Fax 989.752.4444 • www.glastender.com
Page 7
eleCtriCal aND refrigeratioN SpeCifiCatioNS
all moDelS
eleCtriCal refrigeraNt preSSure p.S.i.g
120V, 1 phase, 60 Hz, 6.5 full load amps, 1/4 HP type R134a, Charge 16.0 oz. high 350, low 88
wiriNg Diagram
Glastender, Inc. • 5400 North Michigan Road • Saginaw, MI • 48604-9780
800.748.0423 • 989.752.4275 • Fax 989.752.4444 • www.glastender.com
6
Page 8
CompreSSor aND CoNDeNSer relateD partS
part No. DeSCriptioN priCe
1. 11000084 1/4 HP Tecumseh compressor, R134a $415.00
2. 06001382 Start capacitor for 1/4 HP Tecumseh R134a compressor 25.00
3. 04000243 Relay for 1/4 HP Tecumseh R134a compressor 18.00
4. 06001303 Overload protector for 1/4 HP Tecumseh R134a compressor 25.00
5. 06001445 Condenser fan motor 45.00
6. 06001395 Fan blade, 5 blade, white 5.00
7. 06004180 Bracket, fan, evaporator 14.00
8. 06001393 Condenser coil 230.00
9. 06006088 Fan shroud, condenser 20.00
10. 06001385 Filter dryer, 1/4" x 1/4" 20.00
11. 06000846 Drain pan, condensing unit, endwall cooler 9.00
12. 07000234 Wicking material 24.00
13. 06001350 Tubing, drain, clear plastic, per foot, 3/4" ID 3.50
14. 06000845 Base, condensing unit 22.00
15. 06007476 Thermostat, LED display, range 34-40 degrees F, set to standard, 110v 165.00
15. 06007477 Thermostat, LED display, range 50-55 degrees F, set to white wine, 110v 165.00
15. 06007478 Thermostat, LED display, range 60-65 degrees F, set to red wine, 110v 165.00 06003951 Probe, PVC 5' cable, for use with digital temperature switch 06007476, 06007477, and
06007478
16. 06001313 Condensing unit power cord 20.00 06006096 Expansion valve, 1/8 ton, 134a, cooler/slide top 135.00
30.00
1
3
13
4
6
2
5
16
15
11
8
9
10
14
7
12
7
Glastender, Inc. • 5400 North Michigan Road • Saginaw, MI • 48604-9780
800.748.0423 • 989.752.4275 • Fax 989.752.4444 • www.glastender.com
Page 9
evaporatorS aND relateD partS
part No. DeSCriptioN priCe
06001383 Evaporator fan guard $12.00 06004394 Evaporator fan motor 36.00 06001395 Fan blade, 5 blade, white 5.00 06004180 Bracket, fan evaporator 14.00 06004231 Coil, evaporator 200.00 06004417 Drain pan, evaporator, right 48.00 06004418 Drain pan, evaporator, left 48.00 06007317 Assembly, shroud, evaporator, 2-fan, e/s 150.00 06007476 Thermostat, switch, digital temp, LED display 165.00 06006108 LED light strip 25.00 06009684 Power supply, LED light, endwall cooler 60.00
06001412 Switch 5.00 06000888 Electrical outlet, black (Triboro with no ground) 7.50 06001409 Receptacle, snap in with ground 5.00 06001553 Thermometer 6.00 06003951 Digital temperature probe 30.00
ShelviNg, raCKS aND relateD partS
Note: KC Models come standard with keg racks and do not have required hardware to mount pilasters/shelves.
part No. DeSCriptioN priCe
06004398 Shelf for ND72 middle $77.00 06004389 Shelf (ts end doors) 77.00 06004396 Shelf for middle door 77.00 06004397 Shelf for ND models (end doors) 77.00 06006013 Shelf divider 18.00 06001557 Pilaster 3.00 06001574 Thumbscrew, stainless steel, for pilaster 2.00 06001565 Clip, for pilaster, stainless steel 2.00 00000018 Nut, acorn, 8/32" natural nylon 1.00 06001579 Scuff Channel, standard, 1/2" x 1-1/2" x 18", with mounting screws 26.00 06001580 Scuff Channel, ND, 1/2" x 1-1/2" x 14.5", with mounting screws 26.00
06006264 Wine rack shelf for BB, stainless steel with slots for 7 bottles 126.00 06006265 Wine rack shelf for ND, stainless steel with slots for 5 bottles 126.00 06009974 Keg rack, 16" 195.00 06006236 Keg rack, 18" 195.00 06006234 Keg rack, 20" 195.00 06009975 Keg rack, 22" 195.00 06006235 Keg rack, 24" 195.00
Glastender, Inc. • 5400 North Michigan Road • Saginaw, MI • 48604-9780
800.748.0423 • 989.752.4275 • Fax 989.752.4444 • www.glastender.com
8
Page 10
DoorS aND relateD partS
part No. DeSCriptioN priCe
06001462 Door handle, stainless $60.00 06001653 Door handle, brass 110.00 06001536 Door lock, stainless 36.00 06004009 Key, #806, for stainless cooler door lock (06001536) 4.00 06001535 Door lock, brass 43.00 06004010 Key, #606, for brass cooler door lock (06001535) 4.00 06001677 Plug for door handle, stainless 1.00 06001678 Plug for door handle, brass 1.00 00000200 Screws for top of handle, stainless (set of 2), 10/32 x 1" PFH Machine Screw 1.00 00000016 Screws for top of handle, brass (set of 2) 10/32 x 5/8" PFH Machine Screw 1.00 00000046 Screw for bottom of handle, stainless, and screws for old style brackets .50
00000043 Screw for bottom of handle, black .50 06006207 Hinge set and brackets, 180º swing, left (complete with screws) 35.00 06006208 Hinge set and brackets, 180º swing, right (complete with screws) 35.00 07000356 Lock bracket 5.00 06006596 Hinge set and brackets for wood doors, 180º swing, left (complete with screws) 45.00 06006597 Hinge set and brackets for wood doors, 180º swing, right (complete with screws) 45.00 06006269 Lock bracket for raised wood panel doors 10.00 06004390 Gasket, door, Energy Star cooler, gray, 22-1/2" x 32" OD 45.00 06006178 Gasket, door, Narrow Door Energy Star, gray, 18-1/2" x 32" OD 45.00 00000067 Screw for door hinges (4 required) .50 ea. 00000041 Bolts for brackets (6 required) .50 ea. 06001485 Plastic washer for hinge 1.00 06001569 Bushing for hinge (gray) 1.00
06007095 Standard laminated door trim rail kit 35.00
06007096 Laminated door trim rail kit, for narrow doors 35.00
replaCemeNt DoorS for bb60, bb84, bb108, KC60, KC84, aND KC108 moDelS
part No. DeSCriptioN priCe
06006250 Black vinyl clad door $308.00 06006251 Unlaminated door 308.00 06006252 Laminated door 428.00 06006253 Stainless door 358.00 06006254 Stainless steel glass door 648.00 06006255 Black vinyl clad glass door 598.00 06006256 Laminated glass door 718.00
replaCemeNt DoorS for ND52, ND72, aND ND92 moDelS
part No. DeSCriptioN priCe
06006260 Black vinyl clad door, narrow $308.00 06006261 Unlaminated door, narrow 308.00 06006262 Laminated door, narrow 428.00 06006263 Stainless door, narrow 358.00 06006257 Stainless steel glass door, narrow 648.00 06006258 Black vinyl clad glass door, narrow 598.00 06006259 Laminated glass door, narrow 718.00
9
Glastender, Inc. • 5400 North Michigan Road • Saginaw, MI • 48604-9780
800.748.0423 • 989.752.4275 • Fax 989.752.4444 • www.glastender.com
Page 11
refrigeratioN CompartmeNt CoverS
part No. DeSCriptioN priCe
06007628 Grill, black vinyl clad, for BB and ND w/digital control (control not included),
12" replacement kit
06007629 Grill, stainless, for BB and ND w/digital control (control not included),
12" replacement kit
06007630 Grill, unlaminated, for BB and ND w/digital control (control not included),
12" replacement kit 06001360 Grill insert, refrigeration compartment cover, polypropylene, black 25.00 06001361 Grill insert, refrigeration compartment cover, polypropylene, gray 25.00 06001546 Filter, refrigeration compartment grill insert 7.00 06001848 Laminated compressor compartment trim rail kit, for BB and ND models 39.00 06001555 Rubber bumper 2.15
$120.00
140.00
140.00
220 volt eleCtriCal partS
part No. DeSCriptioN priCe
06006103 Compressor, 1/4 HP, 134a, 220VAC, 60Hz, AEA4430YXD $665.00 06006175 Compressor relay 15.00 06006176 Compressor overload 17.00 06006174 Compressor capacitor 15.00 06006101 Motor, evaporator fan, 220 volt, 1000 rpm (SA 145-232) 30.00 06001448 Motor, fan, 220V, 1300RPM 57.00 06007464 Thermostat, LED display 50-55ºF, set to white wine, 220V 200.00 06007465 Thermostat, LED display 60-65ºF, set to red wine, 220V 200.00 06007463 Thermostat, LED display 34-40ºF, set to standard, 220V 200.00
eleCtriCal CompoNeNtS
part No. DeSCriptioN priCe
06006121 Replacement powercord assembly, includes (06001572 06009527) $40.00
Glastender, Inc. • 5400 North Michigan Road • Saginaw, MI • 48604-9780
800.748.0423 • 989.752.4275 • Fax 989.752.4444 • www.glastender.com
10
Page 12
warraNty StatemeNt
APPLICABLE TO ALL PRODUCTS SOLD WITHIN THE UNITED STATES AND CANADA
Glastender, Inc. warrants all products to be free of defects in mate­rial and workmanship. One-year labor and parts warranty applies to all glasswashers, self-contained refrigeration models, and BDS model bottle disintegration units. In established areas, a start up is included with GT-24 and GT-30 model glasswashers. Warranty is effective for one year from the date of installation or up to 18 months from date of factory shipment, whichever occurs sooner. Glastender, Inc. will replace any part or assembly found defective under normal use and service.
For warranty labor claims beyond 15 months from the date of factory shipment, proof of date of installation or occupancy must be provided. Authorization for labor must be obtained from Glastender within the warranty period and prior to the service being performed.
Labor warranty applies to the United States and Canada only.
Remote refrigeration models and beer line chillers include a one-year parts warranty only. There is no labor warranty on these products.
Field replacement parts not covered under the original warranty include a 90-day part warranty from the date of installation.
FOUR YEAR ADDITIONAL COMPRESSOR WARRANTY: Glastender will warrant to the original user the compressor for all self­contained refrigeration models for an additional four years following the regular one-year warranty period. This plan applies to the compressor only.
A completed warranty claim form MUST accompany all returned defec­tive parts or assemblies. Upon request, a defective part or assembly must be returned to Glastender, Inc., Saginaw, Michigan, with all transporta­tion and delivery charges prepaid. Warranty repairs or replacements will be shipped FOB factory in Saginaw, Michigan. Reimbursement for applicable freight charges covers ground service only.
Glastender provides in-warranty repairs during a service company’s regular working days and hours. There is no provision for payment of a premium rate during “overtime” hours. When warranty service is requested during other than normal working hours, the end user will be charged the premium portion of the overtime rate.
The warranty covers substantiated travel expenses for up to 2 hours / 100 miles round trip up to a maximum of $150. Any additional costs due to installations that require extra work, time, or travel to gain access for service are the sole responsibility of the equipment purchaser. Any exceptions to these travel and access limitations must be pre-approved by a factory representative.
The warranty does not cover door gaskets, chemical tubing, pump squeeze tubing, and/or any equipment subjected to accidents, freight damage, alterations from the original design, improper power and/or plumbing hookups, improper chemical use, general misuse, or lack of routine required maintenance as determined by Glastender, Inc. Installation, normal control adjustments, general maintenance, correct­ing an installation error, or service calls that reveal the unit is function­ing normally will not be reimbursed under warranty.
Condenser coils on self-contained refrigeration products must be cleaned regularly. Failure to provide adequate air flow to a refrigeration unit will void the warranty.
Glastender shall not be liable for loss of use, revenue, or profit, or for any other indirect, incidental, special, or consequential damage includ­ing, but not limited to, product spoilage or loss.
This warranty is conditioned upon Glastender receiving notice of any defect subject to this warranty within sixty (60) days of its discovery by the end user or dealer. All products are warranted only for the initial place of installation. Removal of a product automatically terminates this warranty.
11
Glastender, Inc. • 5400 North Michigan Road • Saginaw, MI • 48604-9780
800.748.0423 • 989.752.4275 • Fax 989.752.4444 • www.glastender.com
SECOND YEAR EXTENDED PARTS & LABOR WARRANTY:
Glastender’s one-year parts and labor warranty on self-contained refrig­eration units, excluding beer line chillers, can be extended to two years with the purchase of a two year parts and labor warranty. Specify part number EWR2 ($150 net price) when ordering.
EXPORT WARRANTY - One year parts only.
EXCLUSION OF WARRANTIES
EXCEPT AS PROVIDED ABOVE, GLASTENDER MAKES NO WARRANTIES, EXPRESS OR IMPLIED, INCLUDING, BUT NOT LIMITED TO, ANY IMPLIED WARRANTY OF MERCHANTABILITY, FITNESS FOR A PARTICULAR PURPOSE OR NON-INFRINGEMENT.
LIMITATION OF REMEDIES AND DAMAGES If Buyer makes a valid and timely claim as outlined above, Glastender’s liability and Buyer’s remedies under this agreement will be limited solely to labor charges authorized and/or replacement or credit, at Glastender’s option, with respect to Products returned at Buyer’s expense within thir­ty (30) days after warranty repair. GLASTENDER’S LIABILITY WILL IN NO EVENT BE GREATER IN AMOUNT THAN THE PURCHASE PRICE OF THE RETURNED PRODUCTS. GLASTENDER WILL NOT BE LIABLE UNDER ANY CIRCUMSTANCE FOR CONSEQUENTIAL OR INCIDENTAL DAMAGES, INCLUDING, BUT NOT LIMITED TO, LABOR COSTS EXCEPT AS COVERED UNDER OUR WARRANTY, LOST PROFITS OR THE LOSS OF PERISHABLE PRODUCTS RESULTING FROM THE USE OF OR INABILITY TO USE OUR PRODUCTS OR FROM OUR PRODUCTS’ INCORPORATION INTO OR BECOMING A COMPONENT OF ANY OTHER PRODUCT. NEITHER PARTY WILL HAVE ANY NEGLIGENCE OR OTHER TORT LIABILITY TO THE OTHER, OR TO ANY THIRD PARTY, ARISING FROM ANY BREACH OF THIS AGREEMENT.
GOVERNING LAW - JURISDICTION
The terms and conditions of an order are to be governed and construed according to the laws of the State of Michigan, without regard to conflict of laws principles. Buyer hereby consents to the jurisdiction and venue of the courts located in Saginaw County, Michigan.
No representative, distributor, dealer, or any other person is authorized to modify this warranty. This warranty replaces all other written or verbal warranties.
NOTE: Glastender, Inc.’s policy of constant quality improvement means that prices, specifications, and policies are subject to change without notice. Questions regarding this warranty should be directed to Glastender’s Warranty Administrator.
04-19-17
IMPORTANT!!
Attention Service Companies
Please review the important warranty information on this page. If you believe a service call should be covered by the factory, please call the factory for authorization between 8AM and 5PM EST, Monday through Friday.
Page 13
termS aND CoNDitioNS
priCeS:
All prices are LIST. Applicable taxes will be added.
quotatioNS:
Unless otherwise stated, quotations are effective for 30 days only.
aCCeptaNCe:
All orders are subject to acceptance by Glastender, Inc.’s headquarters in Saginaw, Michigan. Possession of the Product Directory and Price List is not an offer to sell.
ShipmeNtS:
F.O.B. factory in Saginaw, Michigan. Freight terms are Third Party or Collect if shipped directly to you. Prepay and Add to Invoice freight terms are available upon request. The approximate shipping weights of all products are listed with the prices. Partial shipments will be made unless otherwise specified by the customer. Surface freight classifica­tions are:
GT-24/GT-30/GW24 Glasswashers - Class 175
GT-18 Glasswashers - Class 250
All Underbar Equipment - Class 175
Bar Die Orders – Class 250
Portable Bars - Class 175
Remote refrigerators (i.e., no compressor) or dry storage back bar
equipment - Class 175
Self-contained refrigeration equipment - Class 150
Ice Display Units (IDU and GDU) - Class 85
Lighted Liquor Displays - Class 85
Beer line chillers and beer towers (beverage dispensing equipment)
- Class 92.5
Bottle Disintegration System - Class 150
Ice Cream Freezers - Class 77.5
Delivery:
The majority of equipment is manufactured to order and typically ships within three to six weeks after complete order information is received by the factory. In-stock equipment typically ships within two to three days of the factory receiving complete order information.
returNS:
Items specified as “Manufactured to Order” are NOT returnable.
A Return Authorization number must be issued by the factory in advance for any items that are returnable. The number MUST be noted on the outside of the returned package. Returns must be received within 90 days of the issue date. Shipping charges must be prepaid. A mini­mum 20% restocking charge will be applied to all authorized returns if received in new, unused condition in the original packaging.
The above conditions apply to spare part returns, except spare part returns must be received within 30 days of original shipment for elec­tronic or electrical parts or within 90 days for all other parts.
loSS or Damage:
For customer routed shipments, Glastender, Inc. is not responsible for any loss, damage, or delay of merchandise during shipment. Such transit claims must be filed with the carrier. Merchandise must be examined on arrival. If shortages occur, Glastender, Inc. must be notified in writing within five (5) days of delivery to honor any shortage claim. Glastender will assume responsibility for freight claims on Prepay and Add ship­ments but the customer must inspect freight and note any damage upon receipt. Failure to do so may result in losses at the customer’s expense.
CuStom orDerS:
Custom orders must be paid in advance and are not subject to cancellation.
All small items are evaluated to see the most cost effective means for shipment. Many small items ship via UPS or FedEx; however, when dimensional weight is excessive, LTL carriers are the most cost effective choice. Spare parts orders received before 1:00 PM EST can usually be shipped the same day.
The order department is happy to assist with routing or shipping questions.
paymeNt termS:
Cash should be included with all orders unless credit terms have been arranged. To establish credit, banking and trade references are required. A convenient credit application is available upon request. Payment via credit card is not our normal means of receiving payment. Visa and MasterCard will be accepted, but must be charged at the time of ship­ment. In addition, a payment via credit card for orders totaling more than $500 will incur a 3% convenience fee on the total transaction amount.
Glastender, Inc. • 5400 North Michigan Road • Saginaw, MI • 48604-9780
800.748.0423 • 989.752.4275 • Fax 989.752.4444 • www.glastender.com
lamiNateS:
Some products include common, readily available plastic laminates of the customer’s selection. There may be an additional charge if uncom­mon varieties are ordered.
12/14/17
12
Loading...