glassman LV 8-125, LV 20-50, LV 33-33, LV 40-25, LV 60-18 User Manual

...
OPERATING MANUAL
Operating Manual for
LV SERIES 1000 Watt
Power Supply
TM-10OP-01GL
Operating Manual for
LV SERIES 1000 Watt
Power Supp ly
1000 Watt models: LV 8-125
LV 20-50 LV 33-33 LV 40-25 LV 60-18 LV 80-13 LV 150-7 LV 300-3.5 LV 600-1.7
Warranty
This unit is guaranteed for
three (3
) years from the date of delivery against defe cts in material and workmanship. This does not apply to products damaged through accident, abuse, misuse , or unauthori zed repair. The manufacturer shall not be l iable for any special or consequen tial dama ge of any nature. Th e manufact urer will repair or replace the non-conforming product or issue credit, at its option, provided the manufacturer’s inspection establishes the existence of a defect. Packing, freight, insurance, and other charges incurred in returning the defective products to the manufacturer will be paid by the purchaser . The manufac turer will pay return fr eight if the repaired unit is deemed to be under warranty. If any questions arise conce rning the warranty, check with the manufacturer prior to taking any action.
When requesting informat ion, assistance, or authorization, please state the serial number of the unit, available f rom the label on t he rear pane l of the unit . Give a brief description of the problem. For information about packaging and shipping, see “Packaging for Shipping or Storage,” p. 21.
Information
About Y our
Power
Supply
Release
Please record the following information when you first open your Power Supply package:
Model Number _____________________________________________
Serial Number _____________________________________________
Purchased From _____________________________________________
Purchase Date _____________________________________________
Release 1.0 (2002-02)
ii
Copyright © 2002 Xantrex Technology Inc. All rights reserved. Printed in Canada
Operating Manual for LV 1kW Series Power Supply
Power
Supply
Safety
WARNING—High Energy and High Voltage
Exercise caution when using and calibrating a power supply. High energy levels can be stored at the output voltage terminals on a power supply in normal operation. In addition, potentially lethal voltages exist in the power circuit and on the output and sense connectors of a power supply with a rated output greater than 40 V. Filter capaci tors store potentially dangerous energy for some ti me after power is removed.
CAUTION
!
Operate the power supply in an environment free of flammable gases or fumes. To ensure that the power supply’s safety features are not compromised, use the power supply as specified in this manual and do not substitute parts or make any unauthorized modifications. Contact the service technician for service and repair help. Repairs must be made by experienced service technicians only.
Warnings,
Cautions,
and Notes
Warnings, cautions, and no t es are define d and formatted in this manual as shown below.
WARNING
Describes a potential hazard which could result in injury or death, or, a procedure which, if not performed correctly, could result in injury or death.
CAUTION
!
Describes a procedure which, if not performed correctly, could result in damage to data, equipment, or systems.
Note
Describes additional operating information which may affect the performance of the equipment.
Release 1.0
iii
iv
Operating Manual for LV 1kW Series Power Supply

About This M anual

This Operating Manual contains user information for the LV Series of variable DC output power supplies , available in several vol tage models at 1000 W atts. It provid es information about features and specifications, installation procedures, and basic functions testing, as wel l as operating procedures for using both front panel control and remote analog programming functions.

Who Should Use This Manual

This manual is designed for the user who is familiar with basic el ectrical laws especially as they apply to the operation of power supplies. This implies a recognition of Constant Voltage and Constant Current operating modes and the control of input a nd output power , as well a s the observance of safe techniqu es while making supply or pin connections and any changes in switch settings.

M ain Se ctions

Section 1 Features and Specifications
its features and specifications.
Section 2 Installation
inspection, cleaning, shipping, and storage procedures. Includes AC input connection, basic functions testing, and load and sense lines connections.
Section 3 Operation
Includes procedures for using over voltage protection, shutdown function, multiple supplies, and over temperature protection.
Section 4 Calibration
accuracy.

Manual Revisions

The current release of this manual is listed below. Insert pages may update already printed manuals. Insert material incorporated into a reprinted manual may be identified with a change bar in the page margin.
Release 1.0 (2002-01)
Describes the power supply and lists
Goes through basic setup procedures. Describes
Provides procedures for local (front panel) operation.
Includes calibration for programming and readback
Release 1.0
v
About This Manual
Power Supply Safety Markings
Alternating Current Off (Supply)
Earth (Ground) Terminal Caution (Hot Surface)
Protective Conductor Terminal Caution (Check manual for
additiona l informatio n.)
On (Supply)
vi
Operating Manual for LV 1kW Series Power Supply

Contents

About This Manual . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . v
Section 1.
Features and
Specifications
Section 2.
Installation
Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
Features and Options. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .10
Front Panel Controls. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .10
Rear Panel Connectors and Switch . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .14
Electrical Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .14
Additional Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .16
Input Conditions. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .16
Additional Features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .16
Remote Programming and Monitoring. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .17
Environmental Specification. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .17
Mechanical Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .18
Introduction. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .19
Basic Setup Procedure. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .19
Inspection, Cleaning, and Packaging. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .20
Initial Inspection. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .20
Periodic Cleaning. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .20
Packaging for Shipping or Storage . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .21
Location, Mounting and Ventilation. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .22
Ventilation Requirements. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .22
Rack Mounting. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .22
AC Input Power. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .23
AC Input Voltage Selection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .23
Input Line Impedance. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .24
Functional Tests. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .25
Voltage Mode Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .25
Current Mode Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .26
Controls, Connectors, and Indicators . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .26
Load Connection. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .28
Load Conductor Ratings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .28
Load Connection and Grounding. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .28
Output Cord Strain Relief. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .29
Local and Remote Sensing. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .31

Section 3. Operation

Release 1.0
Single Supply Operation (Local Mode). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .33
Setup . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .33
Voltage Mode Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .33
Current Mode Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .33
Multiple Supplies. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .34
Series Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .34
vii
Contents
Parallel Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 35
Split Supply Operation. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 35
Over Voltage Protection (OVP) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 36
Front Panel OVP Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 36
Remote Programming of OVP With External Voltage Sources. . . . . . . . . . . . . 37
Remote Programming of OVP with an External Resistance. . . . . . . . . . . . . . . 39
Remote Programming of OVP with External Current Sources . . . . . . . . . . . . . 40
Remote OVP Sensing. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 41
Remote ON/OFF . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 42
Remote ON/OFF by Contact Closure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 42
Remote Programming of Output Voltage and Current Limit . . . . . . . . . . . . . . . . . . . 43
Remote Programming Switch SW1. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 43
Programming With External Voltage Sources. . . . . . . . . . . . . . . . . . . . . . . . . . 44
Programming With an External Resistance. . . . . . . . . . . . . . . . . . . . . . . . . . . . 46
Programming With an External Current Source . . . . . . . . . . . . . . . . . . . . . . . . 47
Remote Monitoring and Status Indicators . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 48
Using Over Temperature Protection (OTP) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 49
Resetting the OTP circuit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 49
Section 4.
Calibration
Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 51
Calibration Setup. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 51
Service Environment and Precautions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 51
Calibrating. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 52
viii
Operating Manual for LV 1kW Series Power Supply
Sectio n 1. Features and Sp ecifica tions

Description

This series of power supplie s provides highly stable, variable DC output vol tage and current at 1000 Watts of output power. You can select from several remote control choices: standard ana log programming, o ptional isol ated programmin g or readback, and optional GPIB programming or RS-232 cont rol. It i s designed for a broad range of development, system a nd burn-i n applic ations a nd uses high f requency switching regulator technology to achieve high power density in a small package size. See Table 1.1. for the list of available models.
Table 1.1 Available Voltage and Current Ranges
Model Voltage Range Current Range
8-125 0-8 V 0-125 A 20-50 0-20 V 0-50 A 33-33 0-33 V 0-33 A 40-25 0-40 V 0-25 A 60-18 0-60 V 0-18 A 80-13 0-80 V 0-13 A 150-7 0-150 V 0-7 A 300-3.5 0-300 V 0-3.5 A 600-1.7 0-600 V 0-1.7 A
Release 1.0
9
Features and Specifications

Features and Options

Features and Options
Simultaneous digital display of both voltage and current.
Ten-turn front panel voltage and current controls for high resolution setting of
the output voltage and current from zero to the rated output. Automatic mode crossover into current or voltage mode.
115/230 Vac selectable input voltage, 47–63 Hz single phase.
High frequency switching technology allows high power density, providing
increased power output in a small, light package. Multiple units can be connected in parallel or in series to provide increased
current or voltage and operated in master/slave mode. Remote sensing to compensate for losses in power leads up to 1 V per lead
(0.5 V for 8 V model). Adjustable Over Temperature Protection (OTP).
External TTL, AC, or DC shutdown.
Remote voltage, current l imit and over voltage protection (OVP) programming
with selectable programming ranges. External indicator signals for remote monitoring of O VP status, lo cal/remote
programming status, ther mal shutdown and output voltage and current. Isolated analog remote programming control of the output voltage or current
with the optional ISOL Interface. Optional internal GPIB control for remote digital programming and readback
from a computer.

Front Panel Controls

See Figure 1.1 to review the controls, LEDs, and meters located on the power supply’ s front panel. Check the following sect ions for additional de scriptions of front panel controls and functions.
“Mechanical Specifications” on page 18
“Functional Tests” on page 25
Section 3, “Operation”
10
Operating Manual for LV 1kW Series Power Supply
Features and Specifications
Front Panel Controls
Release 1.0

Figure 1.1 Power Supply Front Panel

11
Features and Specifications

Rear Panel Connectors and Switch

Rear Panel Connectors and Switch
The input AC power, output DC power, as well as the remote program sense and monitor connector are l ocated on the rear panel. The program and monitor f unction selector switch (S W1) is located inte rnally on the main PCB. See Figure 1.2, on page 13 for locations. Refer to Section 2, “Installation” for detail on procedures for connections and settings.
12
Operating Manual for LV 1kW Series Power Supply
Features and Specifications
Rear Panel Co nnectors an d Switch
Release 1.0

Figure 1.2 Power Supply Rear Panel

13
Features and Specifications

Specifications

Specifications
Electrical
These specifications are warrante d over a temperature range of 0 °C to 50 °C.
Specifications

Specifications are subject to change without notice.

Table 1.2 Electrical Specifications for 8 V to 60 V Models
Models 8-125 20-50 33-33 40-25 60-18
Output Ratings:
Output Voltage Output Current Output Power
Line Regulation:
Voltage
1
Current
Load Regulation:
2
Voltage Current
Meter Accuracy:
Voltage
Current OVP Adjustment Range: 0.4-8.8 V 1.0-22 V 1.65-36.3 V 2-44 V 3-66 V Output Noise and Ripple:
(20 Hz - 20 MHz) Voltage (p-p) Voltage (rms)
3
Drift:
Voltage
Current Temperature Coefficient:
4
Voltage
Current Nominal Output Capacitance: 66,000 Nominal Capacitance
(Output to Chassis): 200nF
1. For input voltage variation over the AC input voltage range, wi th con st ant ra t ed l oad .
2. For 0-100% load variation, with constant nominal lin e vol tage.
3. Maximum drift over 8 hou rs with constant line, load and temper at ur e, af te r 9 0 m in ut e warm-up.
4. Change in output per °C c hange in ambient temperature, w ith constant line and load.
0-8 V 0-125 A 1000 W
8mV 125 mA
8mV 125 mA
0.09 V
1.35 A
50 mV 10 mV
4mV
62.5 mA
1.6 mV
37.5 mA
µF
0-20 V 0-50 A 1000 W
20 mV 50 mA
20 mV 50 mA
0.3 V
0.6 A
50 mV 10 mV
10 mV 25 mA
4mV 15 mA
30,000
270n
F
µF
0-33 V 0-33 A 1089 W
33 mV 33 mA
33 mV 33 mA
0.43 V
0.43 A
100 mV 10 mV
16.5 mV
16.5 mA
6.6 mV
9.9 mA 10,000
300n
F
µF
0-40 V 0-25 A 1000 W
40 mV 25 mA
40 mV 25 mA
0.5 V
0.35 A
100 mV 10 mV
20 mV
12.5 mA
8mV
7.5 mA 10,000
250n
F
µF
0-60 V 0-18 A 1080 W
60 mV 18 mA
60 mV 18 mA
0.7 V
0.28 A
150 mV 20 mV
30 mV 9mA
12 mV
5.4 mA 10,000
250n
µF
F
14
Operating Manual for LV 1kW Series Power Supply
Features and Specifications
Table 1.3 Electrical Specifications for 80 V to 600 V Models
Models 80-13 150-7 300-3.5 600-1.7
Output Ratings:
Output Voltage Output Current Output Power
Line Regulation:
Voltage Current
Load Regulation:
Voltage Current
1
2
0-80 V 0-125 A 1040 W
80 mV 13 mA
80 mV 13 mA
0-150 V 0-7 A 1050 W
150 mV 7mA
150 mV 7mA
0-300 V 0-3.5 A 1050 W
300 mV
3.5 mA
300 mV
3.5 mA
0-600 V 0-1.7 A 1020 W
600 mV
1.7 mA
600 mV
1.7 mA
Meter Accuracy:
Voltage Current
0.9 V
0.23 A
1.6 V
0.08 A
4.0 V
0.045 A
7.0 V
0.018 A OVP Adjustment Range: 4-88 V 7.5-165 V 15-330 V 30-660 V Output Noise and Ripple:
(20 Hz - 20 MHz) Voltage (p-p) Voltage (rms)
3
Drift:
Voltage Current
Temperature Coefficient:
4
Voltage Current
Nominal Output Capacitance: 3,000
150 mV 20 mV
40 mV
6.5 mA
16 mV
3.9 mA
µF
200 mV 30 mV
75 mV
3.5 mA
30 mV
2.1 mA 440
µF
200 mV 40 mV
150 mV
1.75 mA
60 mV
1.05 mA 440
µF
500 mV 100 mV
300 mV
0.85 mA
120 mV
0.51 mA
4.7
µF
Nominal Capacitance
250n
(Output to Chassis): 250nF
1. For input voltage variation over the AC input voltage range, wi th con st ant ra t ed l oad .
2. For 0-100% load variation, with constant nominal lin e vol tage.
3. Maximum drift over 8 hou rs with constant line, load and temper at ur e, af t er 9 0 m in ut e warm-up.
4. Change in output per °C c hange in ambient temperature, w ith constant line and load.
F
270n
F
220n
F
Specifications
Release 1.0
15
Features and Specifications
Specifications
Additional
Specifications
Rise Time (No Load, Full Load): Fall Time (No Load):
Fall Time (Full Load): Voltage Mode Transient Response:21ms Time Delay from power on until
output stable
1. Measured with stepped 0-10 V analog programming source and a resistive load.
2. Time for the output voltage to recover within 1% band for 30% step load change from 70% to 100% or 100% to 70%.
Input
Conditions
1
300 ms (full load and no load)
1
1
5s
200 ms
2 s maximum
Additional
Features
Rated AC Input Voltage with Maximum Input Current
200-250 Vac at 10 Arms or 100-130 Vac at
20 Arms Maximum AC Input Power 1300 W at full load Operational AC Input Voltage 200-250 Vac or 100-130 Vac Input Frequency Range 47-63 Hz Power Factor approx. 0.7 at full load
Switching Frequency Nominal 100 kHz, 200 kHz output ripple
>80 V models: 80 kHz, 160 kHz output ripple Output Hold-up Time 15 ms at full load, nominal line Maximum Voltage Differential from
±600 Vdc either output to safety ground
Insulation Resistance Input to chassis: >30 M, with 500 Vdc;
1
Output to chassis: >20 M, with 1000 Vdc. Isolation Voltage Input to output: 1350 Vac
1. To protect from power surges, the units have a 420 Vac varistor built in to act as an
over-voltage clamp. The above insulation resistance specification is subject to be measured with the varistors taken out of the circuit
16
Operating Manual for LV 1kW Series Power Supply