glassman LV 8-125, LV 20-50, LV 33-33, LV 40-25, LV 60-18 User Manual

...
4.3 (3)

OPERATING MANUAL

Operating Manual for

LV SERIES 1000 Watt

Power Supply

TM-10OP-01GL

Operating Manual for

LV SERIES 1000 Watt

Power Supply

1000 Watt models:

LV 8-125

LV 20-50

LV 33-33

LV 40-25

LV 60-18

LV 80-13

LV 150-7

LV 300-3.5

LV 600-1.7

Warranty

Information

About Your

Power

Supply

This unit is guaranteed for three (3) years from the date of delivery against defects in material and workmanship. This does not apply to products damaged through accident, abuse, misuse, or unauthorized repair. The manufacturer shall not be liable for any special or consequential damage of any nature. The manufacturer will repair or replace the non-conforming product or issue credit, at its option, provided the manufacturer’s inspection establishes the existence of a defect. Packing, freight, insurance, and other charges incurred in returning the defective products to the manufacturer will be paid by the purchaser. The manufacturer will pay return freight if the repaired unit is deemed to be under warranty. If any questions arise concerning the warranty, check with the manufacturer prior to taking any action.

When requesting information, assistance, or authorization, please state the serial number of the unit, available from the label on the rear panel of the unit. Give a brief description of the problem. For information about packaging and shipping, see “Packaging for Shipping or Storage,” p. 21.

Please record the following information when you first open your Power Supply package:

Model Number

_____________________________________________

Serial Number

_____________________________________________

Purchased From

_____________________________________________

Purchase Date

_____________________________________________

Release Release 1.0 (2002-02)

Copyright © 2002 Xantrex Technology Inc. All rights reserved.

Printed in Canada

ii

Operating Manual for LV 1kW Series Power Supply

Power

Supply

 

WARNING—High Energy and High Voltage

Safety

 

Exercise caution when using and calibrating a power supply. High energy levels

 

 

can be stored at the output voltage terminals on a power supply in normal

 

 

operation. In addition, potentially lethal voltages exist in the power circuit and on

 

 

the output and sense connectors of a power supply with a rated output greater

 

 

than 40 V. Filter capacitors store potentially dangerous energy for some time after

 

 

power is removed.

 

 

 

 

 

 

 

 

 

 

CAUTION

 

 

 

 

Operate the power supply in an environment free of flammable gases or fumes.

 

 

To ensure that the power supply’s safety features are not compromised, use the

 

 

power supply as specified in this manual and do not substitute parts or make any

 

 

unauthorized modifications. Contact the service technician for service and repair

 

 

help. Repairs must be made by experienced service technicians only.

 

 

 

 

Warnings, Warnings, cautions, and notes are defined and formatted in this manual as shown

Cautions, below. and Notes

WARNING

Describes a potential hazard which could result in injury or death, or, a procedure which, if not performed correctly, could result in injury or death.

CAUTION

Describes a procedure which, if not performed correctly, could result in damage to data, equipment, or systems.

Note

Describes additional operating information which may affect the performance of the equipment.

Release 1.0

iii

iv

Operating Manual for LV 1kW Series Power Supply

About This Manual

This Operating Manual contains user information for the LV Series of variable DC output power supplies, available in several voltage models at 1000 Watts. It provides information about features and specifications, installation procedures, and basic functions testing, as well as operating procedures for using both front panel control and remote analog programming functions.

Who Should Use This Manual

This manual is designed for the user who is familiar with basic electrical laws especially as they apply to the operation of power supplies. This implies a recognition of Constant Voltage and Constant Current operating modes and the control of input and output power, as well as the observance of safe techniques while making supply or pin connections and any changes in switch settings.

Main Sections

Section 1 Features and Specifications Describes the power supply and lists its features and specifications.

Section 2 Installation Goes through basic setup procedures. Describes inspection, cleaning, shipping, and storage procedures. Includes AC input connection, basic functions testing, and load and sense lines connections.

Section 3 Operation Provides procedures for local (front panel) operation. Includes procedures for using over voltage protection, shutdown function, multiple supplies, and over temperature protection.

Section 4 Calibration Includes calibration for programming and readback accuracy.

Manual Revisions

The current release of this manual is listed below. Insert pages may update already printed manuals. Insert material incorporated into a reprinted manual may be identified with a change bar in the page margin.

Release 1.0 (2002-01)

Release 1.0

v

About This Manual

Power Supply Safety Markings

Alternating Current

Off (Supply)

 

 

Earth (Ground) Terminal

Caution (Hot Surface)

 

 

Protective Conductor Terminal

Caution

(Check

manual

for

 

additional information.)

 

On (Supply)

vi

Operating Manual for LV 1kW Series Power Supply

Contents

 

 

About This Manual . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

. v

Section 1.

Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

. 9

Features and

Features and Options . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

10

Specifications

 

 

 

Front Panel Controls. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

10

 

Rear Panel Connectors and Switch . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

12

 

Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

14

 

Electrical Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

14

 

Additional Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

16

 

Input Conditions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

16

 

Additional Features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

16

 

Remote Programming and Monitoring . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

17

 

Environmental Specification. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

17

 

Mechanical Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

18

Section 2.

Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

19

Installation

Basic Setup Procedure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

19

Section 3.

Operation

Inspection, Cleaning, and Packaging . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20 Initial Inspection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20 Periodic Cleaning . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20 Packaging for Shipping or Storage . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21

Location, Mounting and Ventilation. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22

Ventilation Requirements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22

Rack Mounting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22

AC Input Power. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23

AC Input Voltage Selection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23

Input Line Impedance. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24

Functional Tests . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25

Voltage Mode Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25

Current Mode Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26

Controls, Connectors, and Indicators . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26

Load Connection. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28

Load Conductor Ratings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28

Load Connection and Grounding . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28

Output Cord Strain Relief . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29

Local and Remote Sensing. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31

Single Supply Operation (Local Mode) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33

Setup . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33

Voltage Mode Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33

Current Mode Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33

Multiple Supplies. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 34

Series Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 34

Release 1.0

vii

Contents

Parallel Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 35

Split Supply Operation. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 35

Section 4.

Calibration

Over Voltage Protection (OVP) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 36 Front Panel OVP Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 36 Remote Programming of OVP With External Voltage Sources. . . . . . . . . . . . . 37 Remote Programming of OVP with an External Resistance . . . . . . . . . . . . . . . 39 Remote Programming of OVP with External Current Sources . . . . . . . . . . . . . 40 Remote OVP Sensing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 41

Remote ON/OFF . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 42

Remote ON/OFF by Contact Closure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 42

Remote Programming of Output Voltage and Current Limit . . . . . . . . . . . . . . . . . . . 43 Remote Programming Switch SW1. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 43 Programming With External Voltage Sources . . . . . . . . . . . . . . . . . . . . . . . . . . 44 Programming With an External Resistance. . . . . . . . . . . . . . . . . . . . . . . . . . . . 46 Programming With an External Current Source . . . . . . . . . . . . . . . . . . . . . . . . 47

Remote Monitoring and Status Indicators . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 48

Using Over Temperature Protection (OTP) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 49

Resetting the OTP circuit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 49

Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 51

Calibration Setup . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 51

Service Environment and Precautions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 51

Calibrating . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 52

viii

Operating Manual for LV 1kW Series Power Supply

Section 1. Features and Specifications

Description

This series of power supplies provides highly stable, variable DC output voltage and current at 1000 Watts of output power. You can select from several remote control choices: standard analog programming, optional isolated programming or readback, and optional GPIB programming or RS-232 control. It is designed for a broad range of development, system and burn-in applications and uses high frequency switching regulator technology to achieve high power density in a small package size. See Table 1.1. for the list of available models.

Table 1.1 Available Voltage and Current Ranges

Model

Voltage Range

Current Range

 

 

 

8-125

0-8 V

0-125 A

 

 

 

20-50

0-20 V

0-50 A

 

 

 

33-33

0-33 V

0-33 A

 

 

 

40-25

0-40 V

0-25 A

 

 

 

60-18

0-60 V

0-18 A

 

 

 

80-13

0-80 V

0-13 A

 

 

 

150-7

0-150 V

0-7 A

 

 

 

300-3.5

0-300 V

0-3.5 A

 

 

 

600-1.7

0-600 V

0-1.7 A

 

 

 

Release 1.0

9

Features and Specifications

Features and Options

Features and Options

Simultaneous digital display of both voltage and current.

Ten-turn front panel voltage and current controls for high resolution setting of the output voltage and current from zero to the rated output.

Automatic mode crossover into current or voltage mode.

115/230 Vac selectable input voltage, 47–63 Hz single phase.

High frequency switching technology allows high power density, providing increased power output in a small, light package.

Multiple units can be connected in parallel or in series to provide increased current or voltage and operated in master/slave mode.

Remote sensing to compensate for losses in power leads up to 1 V per lead (0.5 V for 8 V model).

Adjustable Over Temperature Protection (OTP).

External TTL, AC, or DC shutdown.

Remote voltage, current limit and over voltage protection (OVP) programming with selectable programming ranges.

External indicator signals for remote monitoring of OVP status, local/remote programming status, thermal shutdown and output voltage and current.

Isolated analog remote programming control of the output voltage or current with the optional ISOL Interface.

Optional internal GPIB control for remote digital programming and readback from a computer.

Front Panel Controls

See Figure 1.1 to review the controls, LEDs, and meters located on the power supply’s front panel. Check the following sections for additional descriptions of front panel controls and functions.

“Mechanical Specifications” on page 18

“Functional Tests” on page 25

Section 3, “Operation”

10

Operating Manual for LV 1kW Series Power Supply

glassman LV 8-125, LV 20-50, LV 33-33, LV 40-25, LV 60-18 User Manual

Features and Specifications

Front Panel Controls

Figure 1.1 Power Supply Front Panel

Release 1.0

11

Features and Specifications

Rear Panel Connectors and Switch

Rear Panel Connectors and Switch

The input AC power, output DC power, as well as the remote program sense and monitor connector are located on the rear panel. The program and monitor function selector switch (SW1) is located internally on the main PCB. See Figure 1.2, on page 13 for locations. Refer to Section 2, “Installation” for detail on procedures for connections and settings.

12

Operating Manual for LV 1kW Series Power Supply

Features and Specifications

Rear Panel Connectors and Switch

Figure 1.2 Power Supply Rear Panel

Release 1.0

13

Features and Specifications

Specifications

Specifications

Electrical These specifications are warranted over a temperature range of 0 °C to 50 °C.

Specifications

Specifications are subject to change without notice.

Table 1.2 Electrical Specifications for 8 V to 60 V Models

Models

8-125

20-50

33-33

40-25

60-18

Output Ratings:

 

 

 

 

 

Output Voltage

0-8 V

0-20 V

0-33 V

0-40 V

0-60 V

Output Current

0-125 A

0-50 A

0-33 A

0-25 A

0-18 A

Output Power

1000 W

1000 W

1089 W

1000 W

1080 W

 

 

 

 

 

 

Line Regulation: 1

 

 

 

 

 

Voltage

8 mV

20 mV

33 mV

40 mV

60 mV

Current

125 mA

50 mA

33 mA

25 mA

18 mA

 

 

 

 

 

 

Load Regulation: 2

 

 

 

 

 

Voltage

8 mV

20 mV

33 mV

40 mV

60 mV

Current

125 mA

50 mA

33 mA

25 mA

18 mA

 

 

 

 

 

 

Meter Accuracy:

 

 

 

 

 

Voltage

0.09 V

0.3 V

0.43 V

0.5 V

0.7 V

Current

1.35 A

0.6 A

0.43 A

0.35 A

0.28 A

 

 

 

 

 

 

OVP Adjustment Range:

0.4-8.8 V

1.0-22 V

1.65-36.3 V

2-44 V

3-66 V

 

 

 

 

 

 

Output Noise and Ripple:

 

 

 

 

 

(20 Hz - 20 MHz)

 

 

 

 

 

Voltage (p-p)

50 mV

50 mV

100 mV

100 mV

150 mV

Voltage (rms)

10 mV

10 mV

10 mV

10 mV

20 mV

 

 

 

 

 

 

Drift:3

 

 

 

 

 

Voltage

4 mV

10 mV

16.5 mV

20 mV

30 mV

Current

62.5 mA

25 mA

16.5 mA

12.5 mA

9 mA

 

 

 

 

 

 

Temperature Coefficient: 4

 

 

 

 

 

Voltage

1.6 mV

4 mV

6.6 mV

8 mV

12 mV

Current

37.5 mA

15 mA

9.9 mA

7.5 mA

5.4 mA

 

 

 

 

 

 

Nominal Output Capacitance:

66,000 F

30,000 F

10,000 F

10,000 F

10,000 F

 

 

 

 

 

 

Nominal Capacitance

 

 

 

 

 

(Output to Chassis):

200nF

270nF

300nF

250nF

250nF

 

 

 

 

 

 

1.For input voltage variation over the AC input voltage range, with constant rated load.

2.For 0-100% load variation, with constant nominal line voltage.

3.Maximum drift over 8 hours with constant line, load and temperature, after 90 minute warm-up.

4.Change in output per ° C change in ambient temperature, with constant line and load.

14

Operating Manual for LV 1kW Series Power Supply

Features and Specifications

Specifications

Table 1.3 Electrical Specifications for 80 V to 600 V Models

Models

80-13

150-7

300-3.5

600-1.7

Output Ratings:

 

 

 

 

Output Voltage

0-80 V

0-150 V

0-300 V

0-600 V

Output Current

0-125 A

0-7 A

0-3.5 A

0-1.7 A

Output Power

1040 W

1050 W

1050 W

1020 W

 

 

 

 

 

Line Regulation: 1

 

 

 

 

Voltage

80 mV

150 mV

300 mV

600 mV

Current

13 mA

7 mA

3.5 mA

1.7 mA

 

 

 

 

 

Load Regulation: 2

 

 

 

 

Voltage

80 mV

150 mV

300 mV

600 mV

Current

13 mA

7 mA

3.5 mA

1.7 mA

 

 

 

 

 

Meter Accuracy:

 

 

 

 

Voltage

0.9 V

1.6 V

4.0 V

7.0 V

Current

0.23 A

0.08 A

0.045 A

0.018 A

 

 

 

 

 

OVP Adjustment Range:

4-88 V

7.5-165 V

15-330 V

30-660 V

 

 

 

 

 

Output Noise and Ripple:

 

 

 

 

(20 Hz - 20 MHz)

 

 

 

 

Voltage (p-p)

150 mV

200 mV

200 mV

500 mV

Voltage (rms)

20 mV

30 mV

40 mV

100 mV

 

 

 

 

 

Drift:3

 

 

 

 

Voltage

40 mV

75 mV

150 mV

300 mV

Current

6.5 mA

3.5 mA

1.75 mA

0.85 mA

 

 

 

 

 

Temperature Coefficient: 4

 

 

 

 

Voltage

16 mV

30 mV

60 mV

120 mV

Current

3.9 mA

2.1 mA

1.05 mA

0.51 mA

 

 

 

 

 

Nominal Output Capacitance:

3,000 F

440 F

440 F

4.7 F

 

 

 

 

 

Nominal Capacitance

 

 

 

 

(Output to Chassis):

250nF

250nF

270nF

220nF

 

 

 

 

 

1.For input voltage variation over the AC input voltage range, with constant rated load.

2.For 0-100% load variation, with constant nominal line voltage.

3.Maximum drift over 8 hours with constant line, load and temperature, after 90 minute warm-up.

4.Change in output per ° C change in ambient temperature, with constant line and load.

Release 1.0

15

Features and Specifications

Specifications

Additional

Specifications

Rise Time (No Load, Full Load): 1

300 ms (full load and no load)

Fall Time (No Load): 1

5 s

Fall Time (Full Load): 1

200 ms

Voltage Mode Transient Response:2

1 ms

Time Delay from power on until

2 s maximum

output stable

 

 

 

1.Measured with stepped 0-10 V analog programming source and a resistive load.

2.Time for the output voltage to recover within 1% band for 30% step load change from 70% to 100% or 100% to 70%.

Input

Conditions

Rated AC Input Voltage with

200-250 Vac at 10 Arms or 100-130 Vac at

Maximum Input Current

20 Arms

 

 

Maximum AC Input Power

1300 W at full load

 

 

Operational AC Input Voltage

200-250 Vac or 100-130 Vac

 

 

Input Frequency Range

47-63 Hz

 

 

Power Factor

approx. 0.7 at full load

 

 

Additional

Features

Switching Frequency

Nominal 100 kHz, 200 kHz output ripple

 

>80 V models: 80 kHz, 160 kHz output ripple

 

 

Output Hold-up Time

15 ms at full load, nominal line

 

 

Maximum Voltage Differential from

±600 Vdc

either output to safety ground

 

 

 

Insulation Resistance

Input to chassis: >30 MΩ , with 500 Vdc;1

 

Output to chassis: >20 MΩ , with 1000 Vdc.

 

 

Isolation Voltage

Input to output: 1350 Vac

 

 

1.To protect from power surges, the units have a 420 Vac varistor built in to act as an over-voltage clamp. The above insulation resistance specification is subject to be measured with the varistors taken out of the circuit

16

Operating Manual for LV 1kW Series Power Supply

Loading...
+ 38 hidden pages