Glas-Col Minitrol Series, Minitwin Series, Minitrol PL312, Minitrol PL3122, Minitrol PL324 User Instructions

...
user instructions
Load Outlet (Prise de Courant)
Pilot Light (Indicateur)
Load Fuse (Fusible)
Dial (Contrôle)
711 HULMAN STREET TERRE HAUTE, IN 47802 812-235-6167
FAX 812-234-6975
Power Controls – Description and Operation
Régulateurs de puissance – Description et mode d’emploi
Description and operation of Glas-Col Minitrol and Minitwin
Catalog Number Capacity Catalog Number Capacity
PL312 12A, 120V PL324 10A, 240V PL3122 15A, 120V
The Glas-Col Minitrol and Minitwin are manually adjusted power controls of percentage-timer design. They are designed to provide full-line voltage to load from 5-1/2% to 100% of time, depending on the dial position. The OFF position positively breaks both sides of line. The controls can be used on any non-inductive load up to rated capacity, and smaller fuses may be used for protection of very small loads.
These controls effectively regulate Glas-Col heating mantles, tapes and cords. Also, they may be used for small furnaces or ovens, hot plates, dies or other applications requiring infinite control.
The maximum combined load for the PL3122 Minitwin is 1800 Watts (15 amps). Minitwin may be used for controlling two separate heating circuits of the same mantle or two separate mantles. The heating circuits may have the same or different power ratings up to 900 Watts (7.5 amps) at 120 Volts.
Operation
PL312 & PL3122
PL324
Dial Setting (Réglage du
cadrant)
Time (Temps) in Seconds
Dial Setting
(Réglage du
cadrant)
Time (Temps) in Seconds
On
Off
Total
Cycle
% ACTIVE
(Pourcentage de
passage du courant)
On
Off
Total
Cycle
% ACTIVE
(Pourcentage de
passage du courant)
LO
4.00
50.00
54.00
7.41%
LO
4.00
53.00
57.00
7.02%
1
4.00
50.00
54.00
7.41%
1 4.00
48.00
52.00
7.69%
2
4.20
31.00
35.20
11.93%
2 4.10
23.00
27.10
15.13%
3
4.60
20.10
24.70
18.62%
3 5.20
13.00
18.20
28.57%
4
5.20
14.60
19.80
26.26%
4 5.50
11.00
16.50
33.33%
5
6.00
11.90
17.90
33.52%
5 7.00
9.00
16.00
43.75%
6
6.40
10.40
16.80
38.10%
6 9.00
6.50
15.50
58.06%
7
7.50
9.00
16.50
45.45%
7 13.00
5.50
18.50
70.27%
8
9.80
7.50
17.30
56.65%
8 17.00
5.00
22.00
77.27%
9
Does not
Go off
Does not
Go off
Does not
Go off
100%
9
Does not
Go off
Does not
Go off
Does not
Go off
100%
HI
Does not
Go off
Does not
Go off
Does not
Go off
100%
HI
Does not
Go off
Does not
Go off
Does not
Go off
100%
Operation of the control is regulated by the operator and does not utilize a sensing element. After a desired temperature has been determined on the initial run, a simple resetting of the dial offers control for repeated operations.
1. Turn control knob to OFF position.
2. Plug device into the 3-wire outlet of the control.
3. Insert plug of the control cord into 3-wire wall or bench receptacle.
4. Adjust knob to desired setting. The pilot (cycle) light is connected across the output side of
the control and indicates power to load.
The control should not be exposed to ambient temperature above 125O F (52 C) Ces régulateurs ne doivant pas être exposés à des températures de plus de 125 F (52 C)
Description et mode d’emploi des régulateurs de puissance Minitrol et Minitwin de Glas-Col
Numéros de catalogue Puissance
PL312 1440 watts, 12A, 120V PL3122 1800 watts, 15A, 120V PL324 2400 watts, 10A, 240V
Les régulateurs de puissance Minitrol et Minitwin, à commande manuelle, fonctionnent en coupant et rétablissant le courant alternativement, c’est-à-dire en augmentant ou diminuant le temps de passage du courant, à plein voltage, de 5-1/2% à 100% selon la position de l’index sur le cadran. La position OFF (hors circuit) coupe le courant des deux côtes. Ces régulateurs peuvent être utilisés jusqu’à leur puissance nominale pour toute charge à résistance non-inductive; on peut se servir de fusibles de moindre ampérage pour protéger des appareils de très faible puissance.
Ces régulateurs sont destinés à régler l’allure des chauffe-ballons, rubans et cordons chauffants de Glas-Col, mais peuvent servir aussi pour régler des fours et des étuves de faibles dimensions, des plaques chauffantes, moules et autres appareils.