6—Maintenance
6.1—General Tips
Only use filtered tap water in this appliance.
Always ensure that the appliance is sitting on a level surface.
If you intend not using the appliance for longer than 2 weeks, remove and empty the sump and water tank.
Once installed, never move this appliance or lay on its back, without draining the water from sump and water tank.
6.2—Cleaning
Warning – Always press Switch ‘A’ to the ‘OFF’ (0) position (Fig.6) and disconnect from the power supply before
cleaning the fire.
We recommend cleaning the following components once every 2 weeks, particularly in hard water areas:Water Tank, Sump, Nozzle, Tank cap and seal, Air filter.
For general cleaning use a soft clean duster – never use abrasive cleaners.
To remove any accumulation of dust or fluff the soft brush attachment of a vacuum cleaner should occasionally be used
to clean the outlet grille of the fan heater.
Water tank
1. Remove water tank, by lifting off the metal plate and set aside. Lift out the tank, place it into a sink and empty
water.
2. Using a soft brush gently rub the inside surfaces of the cap paying particular attention to the rubber ring in the
outer groove and the centre rubber seal.
3. Put a small quantity of washing up liquid into the tank, refit the cap and shake well, rinse out until all traces of
washing up liquid are gone.
4. Refill with filtered tap water only, replace the cap, do not over tighten.
Sump
1. Press Switch ‘A’ to the ‘OFF’ (0) position (Fig.6)
2. Gently lift out the fuelbed and place carefully on the ground
3. Remove the water tank by lifting upwards or in the case of a Mains Water, disconnect the ‘fill cap’ by turning
it clockwise until it clicks out of the locked position. You can now turn it away from the sump.
4. Disconnect the electrical connector, located on the right side of the sump. (Fig.7).
5. There are two clips, one on the left and one on the right hand side of the sump, holding down the sump. On the
left side press in the clip with one hand and with the other lift the nozzle our of the clip. Repeat this for the
right side (Fig.8). The nozzle is now released, lift this off and place aside (Fig.9)
6. Gently lift up the sump (Fig.10), taking care to keep level so as not to spill any water. Sit the sump in the sink.
7. Carefully empty the sump into the sink taking note that the transducer is held in place by a retaining clip.
8. Put a small amount of washing up liquid into the sump, and using a soft brush, gently clean all surfaces in the
sump and gently clean the transducer including the metal discs located in the top grooved surface.
9. When cleaned, thoroughly rinse the sump with clean water to remove all traces of washing up liquid.
10. Clean the Nozzle with the a soft brush and flush out thoroughly with water.
11. Reverse the above steps to reassemble.
Transducer
The transducer is a consumable item and may need to be replaced through time, depending on its usage. To purchase a
replacement transducers, please, contact us. The transducer is fixed in the sump with a plastic clip. If you need to replace your transducer
1. Follow the steps 1-5 in the CLEANING Sump section under ‘Maintenance’ to gain access to the transducer
2. Press the clip back and lift the transducer upwards out of its holder.
3. Remove the cone by turning it clockwise and place it on your new transducer. Turn the cone anticlockwise
until tight to fix it in place