Push button sensor 3 Plus 2-gang F100
Order No. : 2042 xx
Push button sensor 3 Plus 3-gang (1+2) F100
Order No. : 2043 xx
Push button sensor 3 Plus 6-gang (2+4) F100
Order No. : 2046 xx
Operating instructions
1 Safety instructions
Electrical equipment may only be installed and fitted by electrically skilled persons.
Failure to observe the instructions may cause damage to the device and result in fire and other hazards.
These instructions are an integral part of the product, and must remain with the end customer.
2 Device components
Figure 1
(1) Operating rocker (2) Status LED (3) Inscription panel (4) Operation LED
3 Function
System information
This device is a product of the KNX system and complies with the KNX directives. Detailed technical knowledge obtained in KNX training courses is a prerequisite to proper understanding.
The function of this device depends upon the software. Detailed information on loadable software and attainable functionality as well as the software itself can be obtained from the manufacturer´s product database. Planning, installation and commissioning of the device are carried out with the aid of KNX-certified software. The latest versions of product database and the technical descriptions are available on our website.
1/7
32575712 26.07.2013
Push button sensor 3 Plus F100
10860212
KNX/EIB
Intended use
- Operation of loads, e.g. light on/off, dimming, blinds up/down, brightness values,
temperatures, calling up and saving light scenes, etc.
- Measurement and feedback control of the room temperature
- Installation on bus coupling unit 3 in appliance box to DIN 49073
Product characteristics
- The pushbutton functions switching, dimming, controlling blinds, valuators, calling up
moods, etc.
- Three-colour status LED per control surface, which can be switched together or separately
per rocker switch according to the equipment and programming
- Indication of values and texts
- Integrated room temperature sensor
- Room temperature control with setpoint value specification
- Integrated heating timer
- Display of room and setpoint temperature
- Display of outdoor temperature – with external sensor, e.g. weather station
- Operating LED as orientation light
4 Operation
Operating a function or load
Depending on the programming, a control rocker can have up to three functions assigned to it – left, right, entire surface. Operation depends on the specific function.
o Switch: Short press on button. o Dim: Long press on the button. The dimming process ends when the button is released. o Move Venetian blind: Long press on button. o Stop or adjust Venetian blind: Short press on button. o Call up light scene: Short press on button. o Save light scene: Long press on button. o Set value, e.g. brightness or temperature setpoint: Short press on button.
Display symbols and operating modes
The device compares the current room temperature with the setpoint temperature and controls heating or cooling devices according to the current demand. The setpoint temperature depends on the current operating mode and can be changed by the user, depending on the programming. The operating modes and the current controller status are shown in the display.
0 Operating mode Comfort 1 Operating mode Standby 2 Operating mode Night ± Operating mode Frost/heat protection y Comfort extension z Room temperature setpoint manually shifted 6 Dew point. Controller disabled x Controller operation disabled. q Pushbutton sensor disabled. a Fan controller with fan level display Auto/Man.: Automatic or manual fan control. 4 Heating mode ¾ Cooling mode Ø Heating timer is active
! Warning message The function of the display buttons is visible in the display in each case.
>, OK Apply setting, jump to following menu ×, ? Abort, exit menu
32575712 10860212 26.07.2013
2/7
KNX/EIB
Push button sensor 3 Plus F100
n, o Move up/down in the list
<, > Move to the left/right in the list +, – Increase/reduce setting
i The display changes for individual operation steps. The system returns to the basic display
automatically after approx. 15 seconds after the last operation or when any other button is pressed.
Changing the room temperature
For short-term manual modification of the setpoint temperature.
o Press button to the right or left next to the display. o Acknowledge display "setpoint" with >. o Increase or reduce the setpoint temperature with – or +. o Depending on the programming: Accept setting with OK.
The z icon in the display shows that the setpoint temperature was adjusted. With appropriate programming, manual changes to the setpoint temperature are cancelled
by changing the operating mode.
Settings menu.
In the "Settings" menu, the following menu items are available in sequence. Some items are not visible, depending on the programming of the device.
- Fan controller
- Switch-over of the operating mode
- Setting setpoint temperatures
- Setting the heating timer
- Deleting the heating timer
- Set display contrast
Opening and operating the Settings menu
Figure 2
o Press both buttons next to the display simultaneously (Figure 2). o Confirm display "Settings" with >.
The "Settings" menu is displayed.
o Select desired menu item with n or o and confirm with OK.
Heating timer: set switching time
The heating timer selects the operating mode of the room thermostat independently of the day of the week and time – and thus the setpoint temperature of the room. A total of 28 program slots are available for switching times.
o Open menu "Settings", select "Set heating timer" and press OK.
The display shows the first program slot.
o Select program slot with n/o and press OK. o Set hours and press OK. o Set minutes and press OK.
32575712 10860212 26.07.2013
3/7
KNX/EIB
Push button sensor 3 Plus F100
Loading...
+ 4 hidden pages