Gima TEMP SITTER, WT1 User Manual

Page 1
ITALIANO
The user should be aware that changes or modications not explicitly
approved by the compliance manager may void the user’s permission to use the device.
FCC DECLARAION:
• This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a residential environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Nevertheless, there is no guarantee that interference may occur in certain installations.
• Should the device interfere with radio or television reception, which may be detected by switching the device on and off, we encourage users to try correcting the interference by carrying out one or more of the following measures:
- Move or reposition the receiver aerial
- Increase the distance between the device and the receiver.
- Connect the device to a socket on a different electrical circuit to that of the receiver.
- Contact a Radio/TV re-seller or expert technician for assistance.
Designated use
The device is designed for continuous measuring and monitoring of human body temperature. It can store and manage temperature data. It can be used for measuring under-arm temperatures in adults, children and newborns.
Appearance
Front view Rear View
1. Under-arm temperature measurement sensor
Download and Install the Software
1 Methods for downloading the software:
• Users that use devices with the iOS operating system can log into the Apple App Store and search for the “Temp Sitter” app. Alternatively, scan the iOS QR code on the packaging to download.
• Users of the Android system can register on the ofcial wearcare site: http://www.wearcare.cn to download. Or, scan the Android WR code on the packaging which takes you to the aforementioned website. With some Android versions, it may be necessary to enable the installation of software from non-Google Play sources.
2 Download the “Temp Sitter” software, click on the Install button for free
installation.
Instructions for Use
1 Enable Bluetooth on your smartphone or tablet (mobile terminal); 2 Remove the temperature sensor from the packaging. It will switch on a
utomatically and the illuminated indicator will ash rapidly;
3 Start the previously installed software. The device will connect automatically.
When connection is complete, the screen will display “Connection Successful”.
4 Putting the temperature sensor on. The steps are as follows:
Step 1
Step 2
Step 3 Step 4
Step 5
TEMP SITTER - Baby wireless thermometer
PROFESSIONAL MEDICAL PRODUCTS
User manual
ATTENTION: The operators must carefully read and completely understand the present manual before using the product.
Warnings for use
• No modications to the device are permitted.
• Do not use the device together with other TAC or RM apparatus.
• Risk of Explosion: do not use the device on inammable anaesthetic gases
• Do not crush the device. If the case is broken, stop using the device.
• Check the device regularly to ensure that it is in full contact with the skin; otherwise measurements may be inaccurate.
• The device is for indoor use only.
• Pay attention to the temperature and humidity when operating. Use of the device in conditions which do not comply with requirements could lead to measurements being inaccurate.
• Wireless transmission is effective over 15m in an unobstructed area. Over greater distances, the product may not function. Please use this product within the wireless transmission distances indicated here.
• Muscle and fat inuence wireless transmission; therefore the transmission range will be lower if used by adults or overweight children.
• Magnetic and electrical elds may interfere with the correct operation of the device. Therefore, ensure that all other devices operating near the product comply with all Electromagnetic Compatibility (EMC) requirements. Mobile telephones, X-ray or magnetic resonance equipment are possible sources of interference, as they are capable of emitting higher levels of electromagnetic radiation.
• The device is not sterile.
• Doctors should make diagnoses on clinical evidence and symptoms, and use the device only as an accessory.
• This product has been calibrated. No further maintenance or calibration is required, other than replacing the batteries.
• If the system needs upgrading, please update the program.
• The application will always be compatible with other applications in your receiver. Please contact us if you come across this kind of problem.
• If you have any questions regarding the tting, use or maintenance of this device, or encounter any unexpected event, please contact the manufacturer or its representatives.
• Please use and maintain the device according to this manual.
• We recommend that the user uses the original adhesives. We recommend using the device in a cool environment for an improved sense of adaptation to the person. If you feel unwell (discomfort or allergic reaction) during use of the adhesives, please replace the adhesives with another type as advised by a doctor.
• In the event of measurements over long periods of time, please check for any skin allergies in the area. In the event of an allergic reaction, stop use immediately.
• Please do not use adhesives that are supplied folded; use a new adhesive.
• Prepare the skin if used by an adult (e.g. hair removal).
• Please clean the surface of the device with 75% Concentration medical alcohol before and after use. After removing the device, clean the skin that was in contact with the device with medical alcohol. The material in contact with the skin is non-toxic, hypo-allergenic, and will not cause allergic reactions or any other side effects.
• To avoid interruptions caused by telephone calls or SMS during measurement, we recommend activating Airplane Mode and Bluetooth on your iOS/Android device (if a 3G SIM is installed).
• Contact with the device by animals or parasites could cause allergic reactions or other collateral effects in the user. Please clean the surface of the device with 75% concentration medical alcohol before use.
• Improper use by children could damage the temperature measurement sensor and inuence measurement accuracy.
• The temperature sensor activates and deactivates automatically. When you remove the temperature sensor from the packaging, it activates automatically. In the same way, it will switch off automatically when replaced in the packaging.
• When the temperature sensor does not automatically connect to the application connects to the mobile terminal software, the illuminated indicator will ash twice periodically and will receive 2 notications per minute (with the application open or running in the background) of a dropped connection. Once connected, it will ash once periodically.
The product has a temperature check suggestion function; users can set the
alarm value themselves.
• Only one device may be connected for data reception
The device is compliant with Part 15 of FCC regulations. Operation is subject
to the following two conditions:
1 This device cannot cause harmful interference; 2 This device must accept any external interference, including any such
interference which may cause undesired operation.
1
When the temperature sensor connects to mobile terminal application software successfully, the Bluetooth indicator light will shine.
Paste the sticker Paste the device
onto armpit
The measuring result will be transmitted to mobile terminal application software immediately via wireless signal transmission.
Open the packing box and take out the temperature sensor
Gima S.p.A.
Via Marconi, 1 - 20060 Gessate (MI) Italy gima@gimaitaly.com - export@gimaitaly.com
www.gimaitaly.com
Page 2
• Adults should help children wear and operate thr device.
• Please keep the arm straight for at least 5-8 minutes to obtain exact temperature.
• After measurement, replace the sensor in the packaging to avoid battery consumption, as the device is always on.
Note: Different measurement formats and methods can lead to different temperature values.
Maintenance and cleaning
1 Clean the surface of the device before and after use with 75% concentrate
medical alcohol;
2 Stop using the device when the battery indicates low battery, otherwise
the device will not operate correctly;
3 The product has a useful life of 3 years. Disposal of the device and its battery
must be carried out at the end of its useful life in accordance with national laws;
4 The probe must be cleaned and disinfected, but never sterilised. Do not
sterilise the device in an autoclave or otherwise
• If the probe shows signs of damage or deterioration, stop using the device immediately.
• The use of detergents or disinfectants other than alcohol may damage the device and reduce its usable life, or cause a safety risk.
• The electrical screen and the list of components is only supplied to assistance centres or qualied personnel certied by the manufacturer.
• Please refer to the product label for the manufacturing date.
Product specifications
Possibili Problemi e Soluzioni
Guandong Biolight Meditech Co., Ltd.
No. 2 Innovation First Road, Technical Innovation Coast Hi-Tech Zone, Zhuhai, China Made in China
25548 / WT1
M-25548-GB-Rev.0.09.17
Product specifications
Definition of symbols
Manufacturer EMS Guide and Declaration
Guarantee Certificate
If you require technical advice or encounter malfunctions with your device (excluding human error or defects cause by accidents) during the guarantee period, please contact the assistance centre.
NOTE: the same registration and password cannot be shared between multiple devices; we recommend creating a new account for each mobile device.
Production Model WT1
Size 51mm×31.8mm×8.5mm
Weight 9.6g
Measurement specifications
Measurement range 25.00°C~45.00°C (77.00°F~113.00°F)
Measurement accuracy ±0.05°C (35.00°C~38.50°C) \
±0.09°F (95.00°F~101.30°F) ±0.1°C (25.00°C~34.99°C and 38.51°C~45.00°C) \ ±0.18°F (77.00°F~94.99°F) and (101.31°F~113.00°F)
Measurement units for temperature “°C” or “°F”
Update frequency Every 3s
Illuminated Bluetooth indicator Not connected: ashes twice continuously.
Connected: ashes once.
App software platform
iOS System iPhone 4s+, iPad3+, iPad mini
Android System (4.3+) Mobile telephone, Tablet
Battery
Type CR2032, 3V/225mAH button battery
Operating time ≥365 days (8 hours per day)
Environmental specifications
Temperature In use: 5°C~+40°C;
Transportation and storage: -20°C~+55°C
Humidity In use: 25%~95% (without condensation);
Transportation and storage: 25%~95% (without condensation)
Atmospheric pressure In use: 700hPa~1060hPa;
Transportation and storage: 500hPa~1060hPa
Problem Possible Cause Solution
No sound warning The sound system is off Cannot set the sound system
correctly
Unable to establish a connection between the device and the receiver
1. Bluetooth on the receiver is off
2. The Android receiver version is not 4.3 or greater
3. The Bluetooth version is not 4.0
4. Out of range
5. Incorrectly positioned
1. Switch Bluetooth on
2. Update the Android system to version 4.3 or greater
3. Use a receiver device with Bluetooth 4.0
4. Switch off the receiver
5. Change the receiver position
Cannot switch the device on
1. The battery may be low or power missing
2. The device itself may be damaged
1. Restart the device
2. Contact customer services
Cannot see data correctly regarding temperature
1. Device battery is at 1. Restart the device
2. Contact customer services
Number Components WT1
1 Adhesive tape One
2 User manual One
Product name Model name
Product serial number
Guarantee Period
User Name
User address
Contacts Telephone contact
Manufacturer Guide and Declaration - Electromagnetic Emissions
The device is designed for use in electromagnetic areas as specied below. The customer or user must ensure that the product is used in such areas.
Emissions test Compliance Guide - electromagnetic
environment
RF Emissions CISPR 11
Group 1 The device uses RF energy only
for its internal functions. Its RF emissions are therefore very low, and it is improbably that they may cause interference with other electronic devices nearby.
RF Emissions CISPR 11
Class B
The device is suitable for use in all installations, including domestic installations and those connected directly to a low-voltage public power supplier that supplies buildings for domestic use.
Harmonised emissions IEC 61000-3-2
Not applicable (Device operates on batteries)
Current uctuations / icker emissions IEC 61000-3-3
Not applicable (Device operates on batteries)
Shanghai International Holding Corp. GmbH (Europe) Eiffestrasse 80, 20537, Hamburg, Germany
0123
IP27
Simbolo Nota
Keep away from sunlight
Keep in a cool, dry place
Read instructions carefully
Products should not be disposed of with household waste
Part applied of CF type without debrillation protection
IP27
Casing protection class
Refer to this user manual
SN
Serial number
Product complies with European Directive no. 98/79/EC
Manufacturer
Authorized representative in the European community
Product code
Lot number
Loading...