
Gima S.p.A.
Via Marconi, 1 - 20060 Gessate (MI) Italy
gima@gimaitaly.com - export@gimaitaly.com
www.gimaitaly.com
PROFESSIONAL MEDICAL PRODUCTS
OTOSCOPIO PARKER VETERINARIA
PARKER VETERINARY OTOSCOPE
Manuale d’uso - User manual
ATTENZIONE: Gli operatori devono leggere
e capire completamente questo manuale
prima di utilizzare il prodotto.
ATTENTION: The operators must carefully
read and completely understand the present
manual before using the product.
31442
Importato e distribuito da/Imported and distributed by:
Gima S.p.A.
Via Marconi, 1
20060 Gessate (MI) Italy
Made in Pakistan
M31442-M-Rev.0-10.19

ENGLISH
6
FEATURES
The otoscope PARKER (veterinary) is suitable to directly examine the external acoustic duct and the
tympanic membrane. The otoscope PARKER is provided with a screw cap. The model is equipped with
a 2,5 V bulb and are supplied by two 1,5V alkaline batteries type “C”. The otoscopes PARKER are provided with a rheostat to adjust the intensity of light, a removable glass allowing a 3X magnication and
an output for air insufation to check the mobility of the tympanic membrane. The otoscopes PARKER
are delivered in an imitation leather case and are equipped with three autoclavable specula Ø 4 - 5 - 7
mm. The product or its components cannot be used for purposes different from the one specied in the
present manual.
PRESCRIPTIONS
The product shall be used exclusively with alkaline batteries type “C” correctly installed.
It shall not be dipped into water! When cleaning, make sure that the lamp socket or the battery compartment is not soaked with water. Do not use the equipment in case it is damaged. Apply to your
retailer. Avoid precarious repairs. Repairs shall be carried out with original spare parts only, which shall
be installed according to the intended use.
Since the product is made of corrosion-proof materials suitable for the enviromental conditions foreseen for its normal use, does not require special care, however it is necessary to store it in a closed
place making sure that is protected from dust and dirt to assure its hygenic conditions. Moreover, it is
recommended to store the product in a place which can be reached easily by the personnel in case of
necessity.
INSTALLATION
Before using it, it is necessary to insert the batteries into the apposite compartment. Proceed as follows:
- Open the battery compartment. To do this clockwise turn the apposite ring nut located on the handle.
- Once opened, insert the batteries paying attention to the direction of poles (see picture).
- To close the battery compartment, clockwise screw down the ring nut and check that the batteries
are in contact with poles.
In case the otoscope head unit separates from the handle, proceed as follows:
- For PARKER versions with screw cap, it is necessary to slightly unscrew the knob located on the side
and pull the head while tightly holding the otoscope handle.
To reinstall the head unit on the handle, it is sufcient to insert it again into the apposite seat, taking care
that the notch present on the head bottom matches with the knob. At this point it is sufcient to exert a
light pressure towards the bottom and screw the knob
The operation necessary to remove and replace the speculum is very simple:
Counter clockwise rotate the speculum and draw it out of its seat. To reposition the speculum, insert it
into the head group, make the groove match with the small pivot and clockwise rotate.
To dis-assemble the Otoscope unit (with screw locking system) proceed as follows:
- For Otoscopes with screw locking system, it is necessary to slightly unscrew the knob located on the
side and pull up the head while tightly holding the otoscope handle.
- To reinstall the head unit on the handle, it is sufcient to insert it again into the handle, taking care that
the notch present on the head bottom matches.
OPERATION
First of all it is necessary to choose the size and the type of speculum suitable to the acoustic duct to
examine
The examiner shall turn on the light by means of the black knurled ring nut located on the handle upper
side. The model is equipped with a rheostat. Thus pressing the white pushbutton and slowly clockwise
rotating the ring nut it is possible to increase the intensity of light. Counter-clockwise rotate the ring nut
to turn down the light until it is off. After the use, make sure that the light is off.

7
ENGLISH
MAINTENANCE
Periodically check the battery conditions, making sure that no sign of corrosion or oxidation is
present, in case of necessity replace them with new alkaline ones. Carefully handle the batteries as the
liquids they contain can irritate skin and eyes.
Before being used, thoroughly check the product. The same operation shall be carried out after cleaning.
- Check that the connection between the head and the handle is perfect and that the rheostat correctly
works.
- If the light is intermittent or in case it does not turn on, check the bulb, the batteries and the electric
contacts.
In case the bulb stops working, it is possible to replace it with original spare parts (see picture)..
To replace the bulb, it is necessary to take the speculum out, counter-clockwise turn the bulb and screw
the new one down (see picture). It is advisable to use only original bulbs.
Before removing the bulb, make sure that the instrument has been off for some minutes; other-
wise you run the risk of being burnt.
- Check that the glass is clean; on the contrary it shall be removed. To do this counter-clockwise rotate
it and at the same time pull it towards you.
After cleaning, reintroduce the glass into its seat making the groove match with the small pivot and
clockwise rotating it (see picture).
- It is advisable to always have new bulbs and batteries at disposal for the maximum light.
REUSABLE VETERINARY SPECULA
- Made from resilient thermoplastic material.
- Smooth and shiny surface ensure easy cleaning.
- Autoclavable at 134 C.
- Can be disinfected with conventional solutions / water and soap.
- Metallic bayonet lock for positive fit to Otoscope
RECOMMENDED OPERATING ENVIRONMENT
Operation Temperature
Humidity
Air Pressure
Altitude 0-13123 feet (0-4.000 meters)
Storage and Transport Temperature
Humidity
Air Pressure
10°C to 40°C
30% to 75%
700hPa to 1060hPa
-20°C to 60°C
10% to 90%
(Without Condensation)
500hPa to 1060hPa

ENGLISH
8
The product has been conceived to last forever; it is resistant to most part of chemicals except for
methyl ethyl ke tones (M.E.K.), diluents and nail polish removers. All internal parts are brass and chrome
plated preventing rusting. If the lamp is exposed to humidity remove the batteries, thoroughly dry to
avoid short-circuits.
Symbols
Product code
Lot number
Caution: read
instructions (warnings)
carefully
Keep away from sunlight
Keep in a cool, dry place
CE mark
Date of manufacture
WEEE disposal
Follow instructions
for use
Disposal: The product must not be disposed of along with other domestic waste. The users
must dispose of this equipment by bringing it to a specic recycling point for electric and electronic equipment. For further information on recycling points contact the local authorities, the
local recycling center or the shop where the product was purchased. If the equipment is not
disposed of correctly, nes or penalties may be applied in accordance with the national legislation and regulations.
GIMA WARRANTY CONDITIONS
Congratulations for purchasing a GIMA product. This product meets high qualitative standards both as
regards the material and the production.
The warranty is valid for 12 months from the date of supply of GIMA.
During the period of validity of the warranty, GIMA will repair and/or replace free of charge all the defected parts due to production reasons.
Labor costs and personnel traveling expenses and packaging not included.
All components subject to wear are not included in the warranty.
The repair or replacement performed during the warranty period shall not extend the warranty. The
warranty is void in the following cases: repairs performed by unauthorized personnel or with non-original spare parts, defects caused by negligence or incorrect use. GIMA cannot be held responsible
for malfunctioning on electronic devices or software due to outside agents such as: voltage changes,
electro-magnetic elds, radio interferences, etc. The warranty is void if the above regulations are not
observed and if the serial code (if available) has been removed, cancelled or changed.
The defected products must be returned only to the dealer the product was purchased from. Products
sent to GIMA will be rejected.