This document has been realised by EUROCLINIC S.r.l. Unipersonale.
It is prohibited to duplicate or divulge it without authorisation.
Tel +39 0546 656031 Fax +39 0542 656691 e-mail
DATA
date
08/10/2005
APPROVATO
Approved by
M. Longo
info@euroclinic
www.euroclinic.it
DATA
Date
08/10/2005
1
Page 2
Viale dell’artigianato,
305/319
Castelbolognese(RA)
40026
ITALIA
Instructions Manual
Version N° 00
del 08/10/2005
OTO P/V
ELEGANCE
2/11
2
Page 3
MAIN SWITCH
LEVER “A” IN LOW POSITION = CHAIR LOCKED
Instructions Manual
Viale dell’artigianato,
305/319
Castelbolognese(RA)
40026
ITALIA
Version N° 00
del 08/10/2005
OTO P/V
ELEGANCE
3/11
• INSTALLATION
Lift the chair form the packing pallet and lay it on the pavement slowly and without bending it.
Connect the power supply plug to an electric socket, connect the foot-control connector and switch
on the main switch (see Pic. 1).
FOOT-CONTROL
CONNECTOR
POWER SUPPLY
PLUG
Pic.1
• FUNCTIONING
OTO P/V ELEGANCE chair is enabled to make a 360° rotation . To enhance loose rotation it is
enough to keep chromed levers “A” in HIGH position (see picture) with respect to frontal view and
vice-versa to lock the chair on the desired position it is enough to keep the levers “A” in LOW
position (see picture) .
LEVER “A” HIGH POSITION = CHAIR
FREE TO ROTATE AND MOVE
3
Page 4
TO LOWER THE CHAIR
Instructions Manual
Viale dell’artigianato,
305/319
Castelbolognese(RA)
40026
ITALIA
Version N° 00
del 08/10/2005
WARNING!
When rotation is locked (LEVERS DOWN) all electrical movements of rising and lowering of the
chair ARE STOPPED.
OTO P/V
ELEGANCE
4/11
• LIFTING AND LOWERING MOVEMENT
Before lifting the chair, please check that the rotation is locked by pushing on the front-part of
levers “A” – as specified in the previous paragraph.. To lift the chair push the foot-control in the
“UP” position; on the contrary to lower it push the foot-control on the “DOWN” position (see
Pic. 2)
TO LIFT THE
CHAIR
Pic. 2
• REGULATION BACKREST INCLINATION
It is possible to control the backrest inclination through the lever “B”(Pic. 3); when pushing
backward the lever the movement is locked and by forcing the backrest downward you will change
the chair’s position until you reach horizontal position. Once reached the desired position it is
enough to release the lever again. The wider basement allows the chair to stay on horizontal
position (BED POSITION) without any risk of its tipping.
4
Pic.3
LEVER “B” FOR UNLOCKING
BACKREST INCLINATION
Page 5
Instructions Manual
Viale dell’artigianato,
305/319
Castelbolognese(RA)
WARNING!
If the backrest is reclined and if on the chair there is no patient, when unblocking the backrest
through the LEVER “B”, it is advisable to help with a hand the backrest to move forward, so to
avoid a too fast and rough movement. In this case the gas spring is discharged with the patient’s
weight!
• MOBILE ARMREST
To make easier the patient’s sitting and standing position, the armrests can be laterally oriented, as
40026
ITALIA
Version N° 00
del 08/10/2005
OTO P/V
ELEGANCE
5/11
shown in picture 4.
It is necessary to lift upward the armrest and rotate it to the outside. To take it back to original
position you should repeat the movement the other way round.
Pic. 4
• DAILY MAINTENANCE AND CLEANING
The materials used in the construction of the OTO P/V ELEGANCE are suitable for easy cleaning
and disinfection.
Most of pharmaceuticals and chemical products used in a doctor’s room could damage the painted
surfaces and the parts in plastic material.
Tests and inquiries showed that surfaces cannot be completely protected against damages of all
products sold on the market.
The effects of those products are essentially related to the time they remain on the surfaces.
5
Page 6
Instructions Manual
Viale dell’artigianato,
305/319
Castelbolognese(RA)
40026
ITALIA
Version N° 00
del 08/10/2005
It is important to remove immediately with a damp cloth those substances from the surfaces of the
equipment.
Please use only a damp cloth for cleaning; do not spray detergents directly on the chair.
WARNING!
Do not use products containing alcohol, ammonia, abrasive substances or benzol.
The concentrations specified here below are the maximum allowed and cannot be exceeded:
Quaternary Ammonium: maximum 2%
Glutaric Aldehyde: maximum 2%
EUROCLINIC WILL NOT BE HELD RESPONSIBLE FOR DAMAGES CAUSED BY USE OF
DISINFECTANTS WHICH CONTAIN ACTIVE SUBSTANCES DIFFERENT FROM THOSE ABOVE
MENTIONED.
OTO P/V
ELEGANCE
6/11
• ADVICES AND PRECAUTIONS
OTO P/V ELEGANCE chair is supplied with voltage tension 230Vac and it is therefore
compulsory to switch off the main switch and disconnect the plug of power supply before starting
any kind of operation (set up of fuses, spare parts, cleaning, etc;).
Do not lay over weights over 40 Kg on the single leg-rest when it is in horizontal position
because the spring could not be able to support them!
6
Page 7
Viale dell’artigianato,
20001814
20001751X2
22500100
22500150
20001815
22500140
35126053
32900007
52062003
305/319
Castelbolognese(RA)
40026
ITALIA
Instructions Manual
Version N° 00
del 08/10/2005
OTO P/V
ELEGANCE
7/11
SPARE PARTS OTO P/V ELEGANCE
23001842X2
20001574X2
7
Page 8
Viale dell’artigianato,
20001798
20001816
22500147
23001501
20001577
20001570
305/319
Castelbolognese(RA)
40026
ITALIA
Instructions Manual
Version N° 00
del 08/10/2005
OTO P/V
ELEGANCE
8/11
220001571
8
Page 9
Viale dell’artigianato,
21001850
22200021
54313002 X 4
20700004 X2
21500136
65100032
51200011
63701012
305/319
Castelbolognese(RA)
40026
ITALIA
Instructions Manual
Version N° 00
del 08/10/2005
OTO P/V
ELEGANCE
9/11
21500138 DX
21500137 SX
9
Page 10
Viale dell’artigianato,
51200014
207161
--
2
07160
--
207163
--
305/319
Castelbolognese(RA)
40026
ITALIA
Instructions Manual
Version N° 00
del 08/10/2005
OTO P/V
ELEGANCE
10/11
10
Page 11
Instructions Manual
Viale dell’artigianato,
305/319
Castelbolognese(RA)
40026
ITALIA
Version N° 00
del 08/10/2005
OTO P/V
ELEGANCE
11/11
• IDENTIFICATION LABEL
The identification label of the chair is placed on the lifting arm, under the seat.
All details noted are the following:
1. The chair model is specified by a black sign beside the name.
2. In the “clock” up on the right are specified year and month of production.
3. In the charts down on the right are specified the different classes – according to safety rules
on electric components – the Voltage and the Hertz values of power supply tension, the
maximum consumption in Volts/Ampere of the chair.
4. Downside on the left we note in black colour – written with an indelible felt-tip – the serial-
number that guarantees the identification of the chair.
5. Finally you find “CE” and discharge symbols according to EEC regulations in force.