Gima S.p.A.
Via Marconi, 1 - 20060 Gessate (MI) Italy
gima@gimaitaly.com - export@gimaitaly.com
PROFESSIONAL MEDICAL PRODUCTS
www.gimaitaly.com
MANICO FLYER
FLYER HANDLE
MANCHE PORTE-LUMIÈRE FLYER
MANGO FLYER
HANDLICHTQUELLE FLYER
Manuale d’uso - User manual - Manuel de l’utilisateur - Guía de uso
Guia para utilização - Gebrauchs- und instandhaltungsanleitung
ATTENZIONE: Gli operatori devono leggere e capire completamente questo manuale
prima di utilizzare il prodotto.
ATTENTION: The operators must carefully read and completely understand the present manual
before using the product.
AVIS: Les opérateurs doivent lire et bien comprendre ce manuel avant d’utiliser le produit.
ATENCIÓN: Los operadores tienen que leer y entender completamente este manual antes de utilizar el producto.
ATENÇÃO: Os operadores devem ler e entender completamente este manual antes de usar o produto.
ACHTUNG: Diese Anleitung muss vor dem Einsatz des Produkts aufmerksam gelesen und vollständig
verstanden werden.
30794 - 30795
Gima S.p.A.
Via Marconi, 1
20060 Gessate (MI) Italy
Made in Pakistan
M30795-M-Rev.4-12.19

3
ENGLISH
Product
- 30794 yer handle(LED)
- 30795 yer handle (halogen)
A convenient handle that provides focused and bright light. The system is portable and easy to use.
Flyer Handle contains two AAA batteries connected in series and gives 3.0 volt DC thus eliminating the need for adapters. This is the
perfect solution for hectic everyday clinical and hospital life.
Features
Handle: Handle contains two AAA size batteries.
Bottom Cap: Situated at the bottom of each handle. Rotate clockwise to turn ON and Counter clockwise to turn OFF
Connector: Located on the top of each handle and contains LED or halogen Lamp. Connect your instrument here.
LED Specications
LED Voltage: 2.5V
LED Power: 0.33 W
Lux: 60000
Bulb Specications
Voltage: 2.5V
Current: 0.7 amp
Code 31478 bulb (for handle 30795).
Assembling
First of all connect part No. 1 with part No. 2 then insert batteries in the handle and connect part No.3 with part No.2. Now the handle is
ready for use.
Note: Insert the batteries in the right polarity as shown.
Replacement of batteries
Replace 2 batteries at the same time. New batteries should not be mixed with partially exhausted ones. Different batteries or different brands
should not be mixed. Failure to observe these precautions may result problems and thus increase the probability of leakage.
Rechargeable batteries are not recommended. Do not short circuit the batteries terminals. Do not expose the batteries to water or re.

Prescriptions
The product shall be used by qualied personnel only. Do not use the equipment in case it is damaged. Apply to your retailer. Avoid precarious repairs. Repairs shall be carried out with original spare parts only, which shall be installed according to the intended use.
Broken LEDs can cause injuries or cut. Carefully handle and immediately replace.
Use and Maintenance
Place the product in such a way to make sure that it is protected from dust and water to assure its hygienic conditions and protection against
short circuit.
• It is not good practice to use or leave equipment exposed to extreme conditions.
• It is advantageous to remove batteries immediately from equipment which has ceased to function satisfactorily, or when not in use for a
long period.
• Be sure to turn off the equipment after use.
• Store batteries in a cool, dry place and out of direct sunlight. Handle the product with great care.
Before removing the diagnostic unit, make sure that instrument is off. Any unauthorized modication/service may cause short circuit
that may damage the equipment, so always contact the authorized person.
Symbols
Caution: read instructions
(warnings) carefully
Keep in a cool, dry place
Follow instructions for use
Keep away from sunlight
Medical Device complies
with Directive 93/42/EEC
WEEE disposal
4ENGLISH
Manufacturer
Product code Lot number
Disposal: The product must not be disposed of along with other domestic waste. The users must dispose of this equipment by
bringing it to a specic recycling point for electric and electronic equipment.
For further information on recycling points contact the local authorities, the local recycling center or the shop where the product
was purchased. If the equipment is not disposed of correctly, nes or penalties may be applied in accordance with the national
legislation and regulations.
GIMA WARRANTY CONDITIONS
Congratulations for purchasing a GIMA product. This product meets high qualitative standards both as regards the material and the production.
The warranty is valid for 12 months from the date of supply of GIMA.
During the period of validity of the warranty, GIMAwill repair and/or replace free of charge all the defected parts due to production reasons.
Labor costs and personnel traveling expenses and packaging not included.
All components subject to wear are not included in the warranty.
The repair or replacement performed during the warranty period shall not extend the warranty.
The warranty is void in the following cases: repairs performed by unauthorized personnel or with non-original spare parts, defects caused
by negligence or incorrect use.
GIMA cannot be held responsible for malfunctioning on electronic devices or software due to outside agents such as: voltage changes, electromagnetic elds, radio interferences, etc.
The warranty is void if the above regulations are not observed and if the serial code (if available) has been removed, cancelled or changed.
The defected products must be returned only to the dealer the product was purchased from. Products sent to GIMA will be rejected.
Date of manufacture Type B applied part