PROFESSIONAL MEDICAL PRODUCTS
LETTINO GINECOLOGIA
GYNAECOLOGY BED
LIT GYNÉCOLOGIQUE
CAMILLA GINECOLÓGICA
MARQUESA GINECOLÓGICA
GYNÄKOLOGIELIEGE
ΓΥΝΑΙΚΟΛΟΓΙΚΟ ΚΡΕΒΑΤΙ
Manuale d’uso - User manual - Manuel de l’utilisateur - Guía de uso
Guia para utilização - Gebrauchs ungsanleitung - Οδηγίες χρήσης
È necessario segnalare qualsiasi incidente grave vericatosi in relazione al dispositivo medico da noi fornito al fabbricante e all’autorità competente dello
Stato membro in cui si ha sede.
All serious accidents concerning the medical device supplied by us must be reported to the manufacturer and competent authority of the member state
where your registered ofce is located.
Il est nécessaire de signaler tout accident grave survenu et lié au dispositif médical que nous avons livré au fabricant et à l’autorité compétente de l’état
membre où on a le siège social.
Es necesario informar al fabricante y a la autoridad competente del Estado miembro en el que se encuentra la sede sobre cualquier incidente grave que
haya ocurrido en relación con el producto sanitario que le hemos suministrado.
É necessário noticar ao fabricante e às autoridades competentes do Estado-membro onde ele está sediado qualquer acidente grave vericado em relação
ao dispositivo médico fornecido por nós.
Jeder schwere Unfall im Zusammenhang mit dem von uns gelieferten medizinischen Gerät muss unbedingt dem Hersteller und der zuständigen Behörde
des Mitgliedsstaats, in dem das Gerät verwendet wird, gemeldet werden.
Σε περίπτωση που διαπιστώσετε οποιοδήποτε σοβαρό περιστατικό σε σχέση με την ιατρική συσκευή που σας παρέχουμε θα πρέπει να το αναφέρετε στον
κατασκευαστή και στην αρμόδια αρχή του κράτους μέλους στο οποίο βρίσκεστε.
27500 - 27501- 27510
M27500-M-Rev.3-10.21
Gima S.p.A.
Via Marconi, 1 - 20060 Gessate (MI) Italy
gima@gimaitaly.com - export@gimaitaly.com
www.gimaitaly.com
Made in Italy

5
ENGLISH
PRODUCTS
- 27500 DELUXE GYNAECOLOGY BED
- 27501 GYNAECOLOGY BED - STANDARD
- 27510 DELUXE DELIVERY BED - with Trendelenburg
ATTENTION! The operators must carefully read and completely understand the present manual before using the product. In accord with Regulation (EU) 2017/745, this product is part of the CLASS I MEDICAL DEVICES.
DESCRIPTION
Gynecological couch made in strong structure in chrome-plated. Adjustable head and leg section. Available with Trendelenburg position with three
sections with independent controls. Complete with s/s bowl ø 30 cm and leg holders.
COMPONENTS
For cod. 27500 - 27501 For cod. 27510
Upper frame with padded backrest and seat Upper frame with padded backrest and seat
Rear legs Rear legs
Front legs Front legs
Legrest Legrest
Crossing tube Crossing tube
Steel bowl with support Steel bowl with support
Quality leg holders cod. 27500 / standard leg holders cod. 27501 Quality leg holders
ASSEMBLY MATERIAL
For cod. 27500 - 27501 For cod. 27510
N. 2 tbe 8x25 N. 2 tbe 8x25
N. 2 knobs with pin m6x20 ø30
Knobs xed to the quality leg holders (only 27500)
N. 2 knobs with pin m8x20 ø30
For height adjustment of the leg holders
N.2 TE 6X35 + N.2 M6 self-locking hexagon nuts
For backrest and legrest
N.2 TBE 8X50 N.2 TBE 8X50
N.6 washers m8x16 N.6 washers m8x16
N.1 allen key N.1 allen key
N. 2 knobs with pin m6x20 ø30
Knobs xed to the quality leg holders
N. 4 knobs with pin m8x20 ø30
For height adjustment of the leg holders
N.4 TE 6X35 + N.4 M6 self-locking hexagon nuts
For backrest and legrest
ASSEMBLY INSTRUCTIONS
The assembly procedure of the gynecological couch and the model
with trendelenburg is identical except for the assembly phase 2 relative to the seat.

ENGLISH
Begin the assembly phase by setting up a stable horizontal work plan.
6
1) Fix the adjustment rod for backrest by TE 6X35 screw and its hexagen nuts.
2) Only for Trendelenburg: x the adjustment rod for the seat by TE 6X35 screw and its hexagen nuts.
3) Unscrew the TBE 8X16 screws xed on the structure and screw them back by inserting the legs into the tubular frame by the allen key supplied
4) Take TBE 8x25 screws and n.2 washers and x the lower crossing tube to the legs by the allen key supplied.
5) Fix the adjustment rod for legrest by TE 6X35 screw and its self-locking nut.
6) Insert the leg-adjusting rod into the special perforated plate.
7) Fasten the leg supports to the front legs with 2 TBE 8X50 screws and 4 washers
8) Insert the support for the bowl into the tubular welded to the leg. Take the Steel bowl, place it on the support.
9) The KNOBS WITH PIN M6x20 Ø30 are xed to the quality leg holders. Unscrew them, insert leg holders into the tubular and screw knobs.
10) Screw and unscrew the KNOBS WITH PIN M8X20 Ø30 to adjust the height of the leg holders.
NB. The standard leg holders are mounted and they only must to be xed and adjusted by knob.

7
TECHNICAL DATA
ENGLISH
Measurement Cm 180 x 54 x 80 h
Weight 30 kg (32,5 kg with box)
Max Load 110 kg
• cod. 27500/27501 H 138 cm with the backrest up completely and width 65,5 cm including knobs to x the leg
holders
• cod. 27510 H 132 cm with the backrest up completely and width 65,5 cm including knobs to x the leg holders
Frame cm 100 x 53 x 47 h
Trendelenburg’s version: 0° - 46.5° adjustment backrest, 0° - 32° adjustment seatback
Box 143 x 23 x 64 cm
WARNINGS!
- Check the locking nuts are tightened.
- Observe the maximum ow rates indicated in the data sheets.
- Avoid direct contact with open wounds.
- Not for use in open environments.
- When adjusting the height of the couch and the back, make sure that no one inserts hands, legs or anything into the movement area:
CRUSHING RISK!
- Move the bed without lifting it from the oor.
- Before moving the bed, unlock the castors.
MAINTENANCE AND CLEANING
- Use only original spare parts.
- Periodically check all xing points.
- To preserve at best, it is recommended to avoid prolonged exposure to sunlight, to contact and deposit in saline and very humid environments.
- Wash the stainless steel surfaces with soapy water and use appropriate disinfectants.
- Rinse with a damp cloth and dry thoroughly.
- Do not spill on the surface cleaners containing chlorine or ammonia, fatty and oily substances.
- Do not use cleaning utensils containing iron. If necessary disinfection only use suitable non-corrosive products.
Cleaning rules for coating:
- Clean with damp soapy cloth and rinse well with clean water. Do not use solvents, bleaches, synthetic detergents, polishes or aerosol spray.
Attention: Normally synthetic leather light colours should not come in contact with no xed cloured clothes (such as jeans and similar) not to
cause stains and rings that cannot be cleaned up
SYMBOLS
Keep in a cool, dry place Product code
Keep away from sunlight Lot number
Consult instructions for use Manufacturer Medical Device
Date of manufacture
GIMA WARRANTY TERMS
The Gima 12-month standard B2B warranty applies.
Medical Device compliant
with Regulation (EU) 2017/745
Caution: read instructions (warnings)
carefully