ETILOMETRO CON DISPLAY
ALCOHOL TESTER - WITH DISPLAY
ÉTHYLOTEST - AVEC AFFICHAGE
PROBADOR DE ALCOHOL - CON PANTALLA
PROBADOR DE ÁLCOOL - COM PANTALLA
Manuale d’uso - User manual
Manuel de l’utilisateur
Guía de Uso - Guia para utilização
ATTENZIONE: Gli operatori devono leggere e capire
completamente questo manuale prima di utilizzare il prodotto.
ATTENTION: The operators must carefully read and completely
understand the present manual before using the product.
AVIS: Les opérateurs doivent lire et bien comprendre
ce manuel avant d’utiliser le produit.
ATENCIÓN: Los operadores tienen que leer y entender
completamente este manual antes de utilizar el producto.
ATENÇÃO: Os operadores devem ler e entender
completamente este manual antes de usar o produto.
24498
Importato e distribuito da/
Imported and distributed by:
Gima S.p.A.
Via Marconi, 1 - 20060 Gessate (MI) Italy
Made in China
M24498-M-Rev.0-06.19
• APERTURA (BOCCHETTA)
• GAS INLET
• ENTRÉE GAZ
• ENTRADA DE GAS
• ENTRADA DE AR
• INDICATORE “READY”
(dispositivo pronto)
• INDICATOR FOR READY
• INDICATEUR DE PRÊT
• INDICADOR DE LISTO
• INDICADOR DE PRONT
2
O
DISPLAY LCD •
LCD • LCD •
LCD • LCD
TASTO ON/OFF •
ON/OFF KEY •
INTERRUPTEUR •
TECLA ENCENDIDO/APAGADO •
TOUCHE SOUFFLAGE/LUMIÈRE •
TECLA SOPLADO/ILUMINACIÓN •
MARCHE / ARRET
TECLA ON / OFF •
(LIGAR / DESLIGAR)
TASTO BLOW •
BLOW/LIGHT KEY •
TECLA SOPRAR / LUZ •
• INDICATORE BATTERIE
•
• BATTERY INDICATOR
• INDICATEUR DE BATTERIE
• INDICADOR DE LA BATERÍA
• INDICADOR DE BATERIA
• SIMBOLO “NO DRIVING”
(non mettersi alla guida)
• NO DRIVING SYMBOL
• SYMBOLE NE PAS CONDUIRE
• SÍMBOLO DE NO BEBER
• SÍMBOLO DE NÃO CONDUZA
• TASTO DI ACCENSIONE
• START KEY
• TOUCHE DÉMARRAGE
• TECLA DE INICIO
• TECLA DE INÍCIO
ENGLISH
Thanks for purchasing our hand held alcohol tester with display. The alcohol tester gives you a digital reading of
your breath alcohol content and thus your possible concentration of intoxication.
Instruction Manual
1) Install 3 x 1.5V alkaline batteries (AAA) into the battery compartment (auto-cleaning will automatically activate
according to the CAUTION manual) The “AUTO CLEANING” indicator ashes and the display counts down.
Press ON/OFF Key can terminate this “AUTO CLEANING” process.
2) Wash your mouth with water before using. Abstain from smoking or drinking alcohol for at least 5 minutes.
3) Pressing the ON/OFF Key to turn on the power, sensor pre-heating will be activated for an approximate 15
seconds. “Wait” ashes for 9 seconds and then “PH” & “Sta” shows alternatively and the display counts down.
4) Insert a drinking straw or blow tube into the gas inlet located on top of the LCD screen.
5) “READY” lights with a beep tone when count down to zero, and ready to start the test.
6) Press & hold the BLOW Key, the “BLOW” indicator shows on the display. User should blow continuously through
the straw for approximately 7 seconds. Stop blowing when you hear a single beep tone and a reading will be
displayed on the display.
i. A measurement of less than 0.1‰ BAC will show “0.00 ‰ BAC.
ii. A measurement between 0.1‰ & 1.5‰ BAC will show on the display.
iii. A measurement above 1.5‰ BAC, “HI” & “NO DRIVING” will ash on the display with RED backlight.
7
7) User can press START key for another alcohol test. When the display counts down to zero and the “READY”
indicator shows on the display together with beep tones, it is ready to start another test.
Alert Signals
The alcohol tester is designed to alert user as following:
8) Low Level – For measurement below 0.1‰ BAC, “0.00 ‰ BAC” will be shown on display
9) Safety Level – For measurements between 0.00‰ BAC Level (> 0.1‰ BAC) and the alcohol concentration
level shows on the display after test.
10) Alert Level – For measurements equal to or above the alert concentration level, the analyzer beeps together
with alcohol concentration level displays and “NO DRIVING” will then ashes on the LCD for 25 times (about
10s) together with RED backlight.
If reading greater than 1.5‰ BAC, “NO DRIVING” and “HI” will ashes for 25 times (about 10s) together with
RED backlight.
Press START key can stop the beep sound and enter into another test.
YOU ARE PROHIBITED TO DRIVE since you already exceed the alert level.
User Manual for alcohol tester with display
Note:
1) To ensure high precision readings, user should perform the auto-cleaning if unused for more than 2 weeks
(especially for the rst time of using). User should start the auto-cleaning process by removing the batteries and
power up again. The “AUTO CLEANING” indicator ashes. The 5-minutes auto cleaning starts and the display
counts down. The alcohol tester will give few beep sounds at the last minute of auto cleaning. The analyzer will
then turn off automatically after 1 minute and the cleaning process nishes. Before formal test, make sure no
alcohol residues left by blowing fresh air into the gas inlet.
2) Please notice that pressing the ON/OFF key at any time can easily terminate the auto-cleaning process.
3) To achieve an accurate reading, user should ensure there is no alcohol residue inside the chamber before
starting a new alcohol test. Users can pre-check the tester until the ‘0.00’ indication is shown on the display.
This may be achieved by pressing START key once. Holding the BLOW key and blow fresh air into gas inlet for
about few seconds. Alternatively, shaking the unit forwards and backwards several times will allow any alcohol
residue to leave before starting a new alcohol test.
4) After any 4 consecutive tests, allow the device to rest for 2 minutes.
5) An error message “Err” ashes on the display for 5 seconds for the following improper operations:i. When user does not hold the BLOW key for at least 7 seconds during blowing until a beep sound is heard.
ii. When user fails to start the test within 8 seconds after “READY” ashes.
6) When the product is unused, please store in a dry environment.
7) When low battery inductor ashes, the reading is not valid, please replace the batteries immediately.
8) If the difference between two successive reading >0.1‰, user should test again.
ENGLISH
ENGLISH
9) 0.5‰ BAC = 0.05% BAC = 0.25mg/l (if the convection factor is 2.0).
Specication:
1. Range: 0.0 ~ 1.5 ‰ BAC
2. Power Input: 3 x 1.5 AAA Battery (not included)
3. Display: Digital display with bi-color backlight
4. Auto Power Off: 2 minutes
5. Breath Sampling: about 6 seconds continuous breath sample
6. Recycle Time: ~30 seconds
7. Dimension: 107 x 45 x 25 mm
8. Weight: 48g (without battery)
9. Alert Level Calibrated: 0.5‰
10. Agency Approval: CE
11. Accessory: 3 pcs Blowing tubes
Specication subject to change without notice.
The alcohol tester should be used as a general guide to the level of alcohol in your body.
Many factors (e.g. environment gas residue, smoke & various smell in human mouth, etc.) may affect the
BAC level, so the readings are For Reference Only.
Neither the reseller nor manufacturer accept any liability arising from the use of the unit.
Don’t drink before you drive!
Caution: read instructions (warnings)
carefully
Keep in a cool, dry placeKeep away from sunlight
Product codeLot number
Product complies with European
Directive
Consult instructions for use
WEEE disposal
8
9
Disposal: The product must not be disposed of along with other domestic waste. The users must dispose of this equipment by bringing it to a specic recycling point for electric and electronic equipment.
For further information on recycling points contact the local authorities, the local recycling center or the
shop where the product was purchased. If the equipment is not disposed of correctly, nes or penalties
may be applied in accordance with the national legislation and regulations.
GIMA WARRANTY CONDITIONS
Congratulations for purchasing a GIMA product. This product meets high qualitative standards both as regards the
material and the production. The warranty is valid for 12 months from the date of supply of GIMA.
During the period of validity of the warranty, GIMA will repair and/or replace free of charge all the defected parts due
to production reasons. Labor costs and personnel traveling expenses and packaging not included.
All components subject to wear are not included in the warranty.
The repair or replacement performed during the warranty period shall not extend the warranty. The warranty is
void in the following cases: repairs performed by unauthorized personnel or with non-original spare parts, defects
caused by negligence or incorrect use. GIMA cannot be held responsible for malfunctioning on electronic devices
or software due to outside agents such as: voltage changes, electro-magnetic elds, radio interferences, etc. The
warranty is void if the above regulations are not observed and if the serial code (if available) has been removed,
cancelled or changed.
The defected products must be returned only to the dealer the product was purchased from. Products sent to GIMA
will be rejected.
ENGLISH