PROFESSIONAL MEDICAL PRODUCTS
www.gimaitaly.com
Made in Pakistan
39790 - 39794
Side view
Front view
PEDICURE FILE
Detailed Description of the Device
39790
Name: Pedicure File Inox Handle, Double Sided, 21.5 cm
Finish: Mirror / Satin /Sandblast.
39794
Name: Pedicure File Inox Handle, Double Sided, 24cm
Finish: Mirror / Satin / Sandblast.
Instructions of Use
Pedicure File is made of stainless steel type AISI-410 under standard ASTM F-899-84. It is used for
removing rough and excess hard skin (rubbing purpose).
Contents or Composition
ASTM Standard F-899-84
Carbon: 0,126% Manganese: 0,514% Phosphorus: 0,021% Sulphur: 0,015%
Silicon: 0,275% max Chromium: 13,503% Nickel: 0,101%
Indication of Use
• Put away from the reach of uncontrolled person.
• A trained person shall use the devices.
• For professional use only – disinfect before use.
Precautions, restrictions, warnings, special cares
Methods of Proper Cleaning
Proper cleaning requires liquid soap/detergent, water and the use of a clean and disinfected scrub
brush to remove all visible debris and residue.
All items should be scrubbed with a clean and disinfected scrub brush under running water.
ENGLISH
Front view
Side view
NOTE: the cleaning step must be properly performed before an item can be disinfected. All items must
be thoroughly rinsed and dried with clean cloth or paper towels prior to putting them into a disinfectant.
Methods of Proper Disinfecting
After proper cleaning, all reusable implements/tools must be disinfected by complete immersion in
an appropriate disinfecting solution (see below, Appropriate Disinfectants).
The item must be completely immersed so that all surfaces, including handles, are soaked for the
time required on the disinfectant manufacturer’s label.
In general, U.S. Environmental Protection Agency (EPA) registered disinfectants require 10 minute
immersion; isopropyl and ethyl alcohol require 5 minutes.
Remove items after the required time, using clean and disinfected tongs or gloves to avoid skin
contact with the disinfectant solution.
If required by the instruction label, rinse thoroughly under running water.
Allow items to air-dry completely by placing them on top of a clean towel and covering them with
another clean towel.
products are designed to destroy disease-causing microorganisms (pathogens) on non-living surfaces,
such as those described in this document.
They are not appropriate for use on living skin. Contact with skin should be avoided.
Appropriate salon disinfectants include the following:
(a) EPA-registered salon disinfectants with bactericidal, fungicidal and virucidal claims on the label.
Instruments with powder coating color can be sterilized in simple mineral water up to temperature
110 °c for about 5 - 10 minutes.
(b) 10% bleach solution (1 part bleach to 9 parts water)
(c) Isopropyl alcohol, 70%-90% solution
(d) Ethyl alcohol, 70%-90% solution
Individual Client Packs
Tools/instruments kept in individual packs must be properly cleaned and disinfected after each use.
If a client provides their own implements/tools, they must be properly cleaned and disinfected before
use. State rules require all tools and equipment to be disinfected before being reused, even if used by
the same client! Improperly cleaned and disinfected implements may grow infection/disease-causing
organisms before the client returns for their next visit, thereby increasing the risk of infection. Never
use air-tight bags or containers for storage as these can promote bacterial growth.
Methods for Proper Storage of Tools and Equipment
All properly cleaned, disinfected and dried implements/ tools must be stored in a sanitary manner. A
lined drawer is usually adequate, provided it is clean, contains only clean items and is properly labelled.
Store soiled or used items in a properly labelled, covered container separate from clean items. Never
use airtight containers or zipper bags – these may promote bacterial growth!
be thoroughly cleaned by manually brushing with a clean and disinfected brush or by other adequate
best disinfected by immersing in (or saturating with) 70-90% isopropyl or ethyl alcohol for 5 minutes.
Once electric bits have been thoroughly cleaned, they must be disinfected by complete immersion in
an appropriate EPA registered disinfectant, as described in the next section. Any porous (absorbent)
skin or nails must be properly disposed of immediately, as described below.
Contact with Blood, Body Fluid or Unhealthy Conditions
pair of clean protective, disposable gloves and use an EPA-registered Hospital liquid disinfectant or
with an antiseptic and bandage the cut. Disposable items, such as a cotton-tipped wood stick must
be immediately double-bagged and discarded after use, as described at the end of this section. Any
non-porous instrument or implement that comes in contact with an unhealthy condition of the nail
EPA-registered Hospital disinfectant as directed or a 10% bleach solution for 5 minutes. Any porous/
absorbent instrument that comes in contact with an unhealthy condition of the nail or skin, blood or body
GIMA WARRANTY TERMS
The Gima 12-month standard B2B warranty applies.
Product code Lot number
Keep in a cool, dry place Keep away from sunlight
Caution: read instructions
(warnings) carefully
Consult instructions for use
M39790-M-Rev.1.06.20