This manual provides instructions for installing the TRIND® C00011-011 Retrofit Kit into
Encore
The Transmitter/Receiver In Dispenser (TRIND) option allows customers to automatically
authorize Card Reader In Dispenser (CRIND) device-equipped units using a hand-held low
frequency transponder tags provided by a Major Oil Company (MOC) or retailer. Use this kit
for one or two-sided unit.
Important Notice
Retrofit Kit C00011-011 Installation Manual
®
S Series™ units that contain the CRIND® device.
MDE-4544
Encore S Series TRIND
January 2006
This equipment has been tested and found to comply with the limits for a Class A digital
device pursuant to Part 15 of the Federal Communications Commission (FCC) Rules. These
limits are designed to provide reasonable protection against harmful interference when the
equipment is operated in a commercial environment. This equipment generates, uses and can
radiate radio frequency energy, and if not installed and used in accordance with the instruction
manual, may cause harmful interference to radio communications. Operation of this
equipment in a residential area may cause harmful interference in which case the user will be
required to correct the interference at his own expense. Changes or modifications not
expressly approved by the manufacturer could void the user’s authority to operate this
equipment.
The long term characteristics or the possible physiological effects of radio frequency
electromagnetic fields have not yet been investigated by Underwriters’ Laboratories,
Incorporated (UL
Required Reading
Before installing the equipment, the installer must read, understand, and follow:
• this manual
• National Fire Protection Agency (NFPA) 30A, The Automotive and Marine Service
• NFPA 70, The National Electric Code
• applicable federal, state and local codes and regulations
Draft
®
).
Station Code
Failure to do so may adversely effect the safe use and operation of the equipment.
Note: This kit must be installed by a Gilbarco Authorized Service Contractor (ASC)
MDE-4544 Encore S Series TRIND Retrofit Kit C00011-011 Installation Manual • January 2006Page 1
Introduction
Related Documents
Document
Number
MDE-3804Encore and Eclipse Series Start-Up/Service ManualEncore and Eclipse
MDE-4516Encore S Series Owners ManualEncore and Eclipse
MDE-3664TRIND Start-Up, Service, and Parts ManualCRIND and TRIND
PT-1936Encore Illustrated Parts ManualParts Manual
PT-1736CRIND Card Reader Illustrated Parts ManualParts Manual
Recommended Tools
The following equipment is needed to install TRIND kit M02112K00X:
Page 2MDE-4544 Encore S Series TRIND Retrofit Kit C00011-011 Installation Manual • January 2006
Parts Lists
TRIND Retrofit Kit C00011-011 Parts List
The following section provide the parts lists for kit C00011-011. The kit is designed for a dualsided unit.
DescriptionPart NumberQuantity
Assembly, TRIND ElectronicsM06380A0011
Assembly, Light and InductorM06143A00X(see note 1)
Cable Group:Q13863-12 1
• TRIND Door Cable (Side 1)M00507A0011
• TRIND Door Cable (Side 2)M00507A0021
• Cable, TRIND Gateway to CCNM00515A0021
• Cable, TRIND Option Door Data and PowerR20773-G12
• Cable, TRIND Power Enhanced EncoreM06525A0011
Graphics (Envelope)T18832-011
Jumper, 0.100 CentersQ11011-0110
Kit, Encore S Parts:K96646-04-
• Window, TRIND DisplayM05987B0011
Kit, TRIND Encore Component Parts:M02183K001-
• Cable Mount, AdhesiveQ13558-0416
• Screw, Self-Tapping HexQ11677-236
•Tie, CableQ10178-014
Label, Patent and FCCM02962B0071
Notes:
1. Part M06143A00X is a customer specific order entry item (A001 is red, A002 is orange).
2. Part M06525A001 is a customer specific order entry item (based on site survey data).
Parts Lists
Draft
ASC TRIND Tool Kit K94577-02
The following section provide the lists the parts for ASC TRIND Tool Kit K94577-02. The
ASC TRIND Tool kit is a separate order entry item and is not included with the retrofit kit.
DescriptionPart NumberQuantity
Tool Kit, ASC TRIND K94577-02-
• cable, standalone jumperR20602-G21
• test tag, TI/RFID hand heldQ13630-021
MDE-4544 Encore S Series TRIND Retrofit Kit C00011-011 Installation Manual • January 2006Page 3
Important Safety Information
Important Safety Information
This section introduces the hazards and safety precautions associated with installing,
inspecting, maintaining or servicing this product. Before performing any task on this product,
read this safety information and the applicable sections in this manual, where additional
hazards and safety precautions for your task will be found. Fire, explosion, electrical shock or
pressure release could occur and cause death or serious injury if these safe service procedures
are not followed.
Preliminary Precautions
You are working in a potentially dangerous environment of flammable fuels, vapors, and high
voltage or pressures. Only trained or authorized individuals knowledgeable in the related
procedures should install, inspect, maintain or service this equipment.
The first and most important information you must know is how to stop all fuel flow to the
pump and island.
Emergency Total Electrical Shut-Off
Locate the switch or circuit breakers that shut-off all power to all fueling equipment,
dispensing devices, and submerged turbine pumps (STPs). These you must operate in the
event of an emergency.
!
WARNING
The EMERGENCY STOP, ALL STOP, and PUMP STOP buttons at the cashier’s
station WILL NOT shut off electrical power to the pump/dispenser.
This means that even if you activate these stops, fuel may continue to flow uncontrolled.
You must use the TOTAL ELECTRICAL SHUT-OFF in the case of an emergency and
Draft
not only these cashier station “stops.”
Total Electrical Shut-Off Before Access
Any procedure requiring access to electrical components or the electronics of the dispenser
requires total electrical shut-off of that unit.
NFPA 30A, Section 4-1.2, published by the National Fire Protection Association, requires the
installation of an easily accessible switch or circuit breaker to shut-off the power to all fueling
equipment, dispensing devices and STPs in the event of an emergency. Know the function and
location of this switch or circuit breaker before inspecting, installing, maintaining, or servicing
Gilbarco equipment.
Page 4MDE-4544 Encore S Series TRIND Retrofit Kit C00011-011 Installation Manual • January 2006
Important Safety Information
Evacuation, Barricading and Shut-Off
Any procedures requiring accessing the pump/dispenser or STPs requires the following three
actions:
• An evacuation of all unauthorized persons and vehicles
• Using safety tape or cones as barricades to the effected units
• A total electrical shut-off of that unit
Read the Manual
Read, understand and follow this manual and any other labels or related materials supplied
with this equipment. If you do not understand a procedure, call a Gilbarco Authorized Service
Contractor or call the Gilbarco Call Center at 1-800-800-7498. It is imperative to your safety
and the safety of others to understand the procedures before beginning work.
Follow the Regulations
There is applicable information in: NFPA 30A: Automotive and Marine Service Code; NFPA
70: National Electrical Code (NEC); OSHA regulations; and federal, state, and local codes
which must be followed. Failure to install, inspect, maintain or service this equipment in
accordance with these codes, regulations and standards may lead to legal citations with
penalties or affect the safe use and operation of the equipment.
Safety Symbols and Warning Words
This section provides important information about warning symbols and boxes.
Alert Symbol
This safety alert symbol is used in this manual and on warning labels to alert you to
a precaution which must be followed to prevent potential personal safety hazards. Obey safety
directives that follow this symbol to avoid possible injury or death.
Draft
MDE-4544 Encore S Series TRIND Retrofit Kit C00011-011 Installation Manual • January 2006Page 5