Gilbarco GBIR15 User Manual

Introduction

Purpose

This manual provides instructions for installing the TRIND® C00011-011 Retrofit Kit into Encore
The Transmitter/Receiver In Dispenser (TRIND) option allows customers to automatically authorize Card Reader In Dispenser (CRIND) device-equipped units using a hand-held low frequency transponder tags provided by a Major Oil Company (MOC) or retailer. Use this kit for one or two-sided unit.

Important Notice

Retrofit Kit C00011-011 Installation Manual
S Series™ units that contain the CRIND® device.
MDE-4544
Encore S Series TRIND
January 2006
This equipment has been tested and found to comply with the limits for a Class A digital device pursuant to Part 15 of the Federal Communications Commission (FCC) Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses and can radiate radio frequency energy, and if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area may cause harmful interference in which case the user will be required to correct the interference at his own expense. Changes or modifications not expressly approved by the manufacturer could void the user’s authority to operate this equipment.
The long term characteristics or the possible physiological effects of radio frequency electromagnetic fields have not yet been investigated by Underwriters’ Laboratories, Incorporated (UL

Required Reading

Before installing the equipment, the installer must read, understand, and follow:
• this manual
• National Fire Protection Agency (NFPA) 30A, The Automotive and Marine Service
• NFPA 70, The National Electric Code
• applicable federal, state and local codes and regulations
Draft
).
Station Code
Failure to do so may adversely effect the safe use and operation of the equipment.
Note: This kit must be installed by a Gilbarco Authorized Service Contractor (ASC)
MDE-4544 Encore S Series TRIND Retrofit Kit C00011-011 Installation Manual • January 2006 Page 1
Introduction

Related Documents

Document Number
MDE-3804 Encore and Eclipse Series Start-Up/Service Manual Encore and Eclipse
MDE-4516 Encore S Series Owners Manual Encore and Eclipse
MDE-3664 TRIND Start-Up, Service, and Parts Manual CRIND and TRIND
PT-1936 Encore Illustrated Parts Manual Parts Manual
PT-1736 CRIND Card Reader Illustrated Parts Manual Parts Manual

Recommended Tools

The following equipment is needed to install TRIND kit M02112K00X:
• clean cloth or rag
• isopropyl alcohol (part number END-1082)
• nut drivers, metric
• nut drives, standard
• multimeter
• needle nose pliers
• pliers
• pocket knife
• putty knife or scraper
• Diagnostic Card Q12534-170
• ratchet set, metric
• ratchet set, standard
• screwdrivers, flat and Phillips head
• static guard wrist strap
• TRIND ASC tool kit K94577-02 (refer to MDE-3640 ASC TRIND Installation Tool Kit)
Description GOLD Library
Draft
Page 2 MDE-4544 Encore S Series TRIND Retrofit Kit C00011-011 Installation Manual • January 2006

Parts Lists

TRIND Retrofit Kit C00011-011 Parts List

The following section provide the parts lists for kit C00011-011. The kit is designed for a dual­sided unit.
Description Part Number Quantity
Assembly, TRIND Electronics M06380A001 1
Assembly, Light and Inductor M06143A00X (see note 1)
Cable Group: Q13863-12 1
• TRIND Door Cable (Side 1) M00507A001 1
• TRIND Door Cable (Side 2) M00507A002 1
• Cable, TRIND Gateway to CCN M00515A002 1
• Cable, TRIND Option Door Data and Power R20773-G1 2
• Cable, TRIND Power Enhanced Encore M06525A001 1
Graphics (Envelope) T18832-01 1
Jumper, 0.100 Centers Q11011-01 10
Kit, Encore S Parts: K96646-04 -
• Window, TRIND Display M05987B001 1
Kit, TRIND Encore Component Parts: M02183K001 -
• Cable Mount, Adhesive Q13558-04 16
• Screw, Self-Tapping Hex Q11677-23 6
•Tie, Cable Q10178-01 4
Label, Patent and FCC M02962B007 1
Notes:
1. Part M06143A00X is a customer specific order entry item (A001 is red, A002 is orange).
2. Part M06525A001 is a customer specific order entry item (based on site survey data).
Parts Lists
Draft

ASC TRIND Tool Kit K94577-02

The following section provide the lists the parts for ASC TRIND Tool Kit K94577-02. The ASC TRIND Tool kit is a separate order entry item and is not included with the retrofit kit.
Description Part Number Quantity
Tool Kit, ASC TRIND K94577-02 -
• cable, standalone jumper R20602-G2 1
• test tag, TI/RFID hand held Q13630-02 1
MDE-4544 Encore S Series TRIND Retrofit Kit C00011-011 Installation Manual • January 2006 Page 3

Important Safety Information

Important Safety Information
This section introduces the hazards and safety precautions associated with installing, inspecting, maintaining or servicing this product. Before performing any task on this product, read this safety information and the applicable sections in this manual, where additional hazards and safety precautions for your task will be found. Fire, explosion, electrical shock or pressure release could occur and cause death or serious injury if these safe service procedures are not followed.

Preliminary Precautions

You are working in a potentially dangerous environment of flammable fuels, vapors, and high voltage or pressures. Only trained or authorized individuals knowledgeable in the related procedures should install, inspect, maintain or service this equipment.
The first and most important information you must know is how to stop all fuel flow to the pump and island.

Emergency Total Electrical Shut-Off

Locate the switch or circuit breakers that shut-off all power to all fueling equipment, dispensing devices, and submerged turbine pumps (STPs). These you must operate in the event of an emergency.
!
WARNING
The EMERGENCY STOP, ALL STOP, and PUMP STOP buttons at the cashier’s station WILL NOT shut off electrical power to the pump/dispenser.
This means that even if you activate these stops, fuel may continue to flow uncontrolled.
You must use the TOTAL ELECTRICAL SHUT-OFF in the case of an emergency and
Draft
not only these cashier station “stops.”

Total Electrical Shut-Off Before Access

Any procedure requiring access to electrical components or the electronics of the dispenser requires total electrical shut-off of that unit.
NFPA 30A, Section 4-1.2, published by the National Fire Protection Association, requires the installation of an easily accessible switch or circuit breaker to shut-off the power to all fueling equipment, dispensing devices and STPs in the event of an emergency. Know the function and location of this switch or circuit breaker before inspecting, installing, maintaining, or servicing Gilbarco equipment.
Page 4 MDE-4544 Encore S Series TRIND Retrofit Kit C00011-011 Installation Manual • January 2006
Important Safety Information

Evacuation, Barricading and Shut-Off

Any procedures requiring accessing the pump/dispenser or STPs requires the following three actions:
An evacuation of all unauthorized persons and vehicles
Using safety tape or cones as barricades to the effected units
A total electrical shut-off of that unit

Read the Manual

Read, understand and follow this manual and any other labels or related materials supplied with this equipment. If you do not understand a procedure, call a Gilbarco Authorized Service Contractor or call the Gilbarco Call Center at 1-800-800-7498. It is imperative to your safety and the safety of others to understand the procedures before beginning work.

Follow the Regulations

There is applicable information in: NFPA 30A: Automotive and Marine Service Code; NFPA 70: National Electrical Code (NEC); OSHA regulations; and federal, state, and local codes which must be followed. Failure to install, inspect, maintain or service this equipment in accordance with these codes, regulations and standards may lead to legal citations with penalties or affect the safe use and operation of the equipment.

Safety Symbols and Warning Words

This section provides important information about warning symbols and boxes.

Alert Symbol

This safety alert symbol is used in this manual and on warning labels to alert you to a precaution which must be followed to prevent potential personal safety hazards. Obey safety directives that follow this symbol to avoid possible injury or death.
Draft
MDE-4544 Encore S Series TRIND Retrofit Kit C00011-011 Installation Manual • January 2006 Page 5
Important Safety Information

Signal Words

These signal words used in this manual and on warning labels tell you the seriousness of particular safety hazards. The precautions that follow must be followed to prevent death, injury or damage to the equipment.
!
DANGER
This signal word is used to alert you to a hazard or unsafe practice which will result in death or serious injury.
!
WARNING
This alerts you to a hazard or unsafe practice that could result in death or serious injury.
!
CAUTION
This signal word designates a hazard or unsafe practice which may result in minor injury.
CAUTION
When used by itself, CAUTION designates a hazard or unsafe practice which may result in
property or equipment damage.

Prevent Explosions and Fires

Fuels and their vapors will become explosive if ignited. Spilled or leaking fuels cause vapors. Even filling customer tanks will cause explosive vapors in the vicinity of dispenser or island.

No Open Flames

Open flames from matches, lighters, welding torches or other sources can ignite fuels and their vapors.

No Sparks - No Smoking

Sparks from starting vehicles, starting or using power tools, burning cigarettes,
cigars or pipes can also ignite fuels and their vapors. Static electricity, including an electrostatic charge on your body, can cause a spark sufficient to ignite fuels and their vapors. After getting out of a vehicle, touch the metal of your vehicle to discharge any electrostatic charge before you approach the dispenser island.
Draft
Page 6 MDE-4544 Encore S Series TRIND Retrofit Kit C00011-011 Installation Manual • January 2006

Other Useful Safety Information

This subsection provides additional safety information.

OSHA Lock-Out and Tag-Out Requirements

OSHA Standard 29 CFR 1910-147 Control of Hazardous Energy Sources (Lock-Out/Tag-Out) covers ways to avoid personal injury because power was turned on or fuel pressure was applied unexpectedly while servicing equipment. The rule requires:
(1) Turning off equipment power and fuel under pressure.
(2) Use of a locking device (breaker, valve, etc.) or label device with a warning tag.
Station employees and service contractors need to understand and comply with this program completely to ensure safety while the equipment is down.

Use Electrostatic Discharge Precautions

Place yourself at a neutral static-free potential by doing the following:
Important Safety Information

1 Touch an unpainted metal surface.

2 Use a wrist strap connected to a grounded metal frame or chassis.

3 Make sure all power has been removed from unit and the CRIND device.

Draft
MDE-4544 Encore S Series TRIND Retrofit Kit C00011-011 Installation Manual • January 2006 Page 7

Installation

Installation
Perform the following procedures to install TRIND Retrofit Kit C00011-011. The installation procedures for this manual consists of the following sections:
• Addressing the Gateway Board
• Installing the Enhanced Gateway Board (TRIND Electronics - M06380A001)
• Installing Light and Inductor Assembly M06143A00X
• Routing Cables
• TRIND Cable Block Diagram R20775, Sheet 2
• Enabling the TRIND Device and Verifying Addresses
• Testing the TRIND Device
• Completing Installation

Addressing the Gateway Board

The jump jacks on Gateway Board T20678-GX (Figure 1) are easier to set prior to installing the Card Cage Assembly into the dispenser. Complete the following procedures to setup addresses on the Gateway Board. The Gateway Board contains jump jacks that are used to setup addresses that will match addresses set in software on CRIND Control Node PCA M00089. Perform the following steps to setup addresses on the Gateway Board.
Figure 1: Gateway Board T20678-GX Jump Jack Location
Jump jack locations on Gateway Board
Draft
Page 8 MDE-4544 Encore S Series TRIND Retrofit Kit C00011-011 Installation Manual • January 2006
Installation
1 Set the jump jacks (Figure 1) on Gateway Board T20678-GX to match the CRIND addresses
of the fueling unit subject to TRIND installation. Refer to the following table for the jack settings that correspond to a CRIND address.
Note: For generic CRIND, address the Gateway Board to correspond with the proper CRIND
address. This should be done in accordance with Site Controller requirements.
MOC Encore CRIND Addresses Jack Settings
Side 1 = Address on Gateway Board T20678 ‘A’ Side JP6 JP7 JP8 JP9 JP10
Side 2 = Address on Gateway Board T20678 ‘B’ Side JP14 JP15 JP16 JP17 JP18
1 IN OUT OUT OUT OUT
2 OUT IN OUT OUT OUT
3 IN IN OUT OUT OUT
4 OUT OUT IN OUT OUT
5 IN OUT IN OUT OUT
6 OUT IN IN OUT OUT
7 IN IN IN OUT OUT
8 OUT OUT OUT IN OUT
9 IN OUT OUT IN OUT
10 OUT IN OUT IN OUT
11 IN IN OUT IN OUT
12 OUT OUT IN IN OUT
13 IN OUT IN IN OUT
14 OUT IN IN IN OUT
15 IN IN IN IN OUT
16 OUT OUT OUT OUT IN
17 IN OUT OUT OUT IN
18 OUT IN OUT OUT IN
19 IN IN OUT OUT IN
20 OUT OUT IN OUT IN
Draft
21 IN OUT IN OUT IN
22 OUT IN IN OUT IN
23 IN IN IN OUT IN
24 OUT OUT OUT IN IN
25 IN OUT OUT IN IN
26 OUT IN OUT IN IN
27 IN IN OUT IN IN
28 OUT OUT IN IN IN
29 IN OUT IN IN IN
30 OUT IN IN IN IN
31 IN IN IN IN IN
32 OUT OUT OUT OUT OUT
MDE-4544 Encore S Series TRIND Retrofit Kit C00011-011 Installation Manual • January 2006 Page 9
Installation

Installing the Enhanced Gateway Board (TRIND Electronics - M06380A001)

Install the enhanced gateway board assembly from Side 2 of the unit according to the following steps:
1 Place the assembly on the shelf provided, aligning four studs on underside of card cage with
holes provided on shelf.
2 Secure assembly to shelf using three (3) nuts (M00414B005) with external lock washers
provided with kit.

Installing Light and Inductor Assembly M06143A00X

Perform the following steps to install Light and Inductor Assembly M06143A00X.

1 Install M06143A00X to Encore S bezel using three (3) screws (Q11677-24) provided.

2 Repeat step 1 for the other side bezel.

Routing Cables

Perform the following steps to install retrofit kit cables. Refer to “TRIND Cable Block
Diagram R20775, Sheet 2” on page 13 for details on making connections.

1 Obtain AC Power Cable M06525A001 from the kit.

2 Locate the M00806A00X AC Power Distribution Cable inside the electronics cabinet of the
dispenser. Attach plug P1 of AC Power Cable M06525A001 to one of the AC taps on AC Power Distribution Cable M00806A00X .
3 Attach the ground connection of AC Power Cable M06525A001 to a convenient chassis
ground.
4 Obtain Light/Multi-Protocol Cable R20773-G1 from the kit and connect the J182 end of the
cable to P182 on Light Board Assembly M06143A001.

5 Secure the R20773-G1 Cable to door, and route and feed the other cables.

6 For both CIM Doors, use cable clamps to route cables to and along the door.

Note: Be sure that the cables are secured with sufficient slack to allow door to open and close
without pinching the cabling.
7 Connect the J1/J2 end of the R20773-GX cable to P2 end of the M00507A00X Ribbon Cable
extending from the Card Cage Assembly .
Draft
Page 10 MDE-4544 Encore S Series TRIND Retrofit Kit C00011-011 Installation Manual • January 2006
Figure 2: M00507A00X Ribbon Cable
Installation
J282A/J282B
8 Obtain Light/Multi-Protocol Cable R20773-G1 from the kit and connect the J182 end of the
cable to P182 on the Light Board Assembly M06143A00X.

9 Secure the R20773-G1 Cable to the door and route the cable through the bezel.

10 Feed cables into the CIM door.

11 Use the cable clamps to route the cables to and along the door.

Note: Be sure that cables are secured with sufficient slack to allow door to open and close
without pinching the cabling.
P1/P2
12 Connect the J1/J2 end of the R20773-G1 cable to the P1 end of the M00507A00X Ribbon
Cable extending from the Card Cage Assembly.
13 Obtain TRIND Gateway Ribbon Cable M00515A00X from the kit and perform the following
to connect Enhanced Gateway Board T20678-GX to CRIND Control Node Printed Circuit Assembly M00089A00X :
• Connect J250 on gateway cable M00515A00X to plug P250 on Enhanced Gateway Board
• Connect J3110 on gateway cable M00515A00X to plug P3110 on CRIND Control Node
Figure 3: TRIND Gateway 14 Position Ribbon Cable M00515A00X
J3110
Draft
T20678-GX
PCA.
J250
MDE-4544 Encore S Series TRIND Retrofit Kit C00011-011 Installation Manual • January 2006 Page 11
Installation
Figure 4: Enhanced Gateway Printed Circuit Board Assembly T20678-GX
PWR = 5V
CPU = Software Running
RX = From A Side CRIND
TX = To A Side CRIND
RX = From B Side CRIND
TX = To B Side CRIND
P250
Figure 5: CRIND Control Node PCA M00089A00X
Draft
P3110
Page 12 MDE-4544 Encore S Series TRIND Retrofit Kit C00011-011 Installation Manual • January 2006
Installation

TRIND Cable Block Diagram R20775, Sheet 2

Draft
M04104AXXX
DIN Rail Power
Supply Assy.
MDE-4544 Encore S Series TRIND Retrofit Kit C00011-011 Installation Manual • January 2006 Page 13
Installation

Enabling the TRIND Device and Verifying Addresses

Perform the following steps to enable the TRIND device and verify the CRIND addresses that with the Gateway Board.
1 Restore power to the fueling units. Refer to MDE-3804 Encore and Eclipse Series Start-Up/
Service Manual.

2 Initiate CRIND BIOS Diagnostics using Diagnostic Card Q12534-170.

3 At the Diagnostic Startup Menu window select 1. Main Menu.

4 At Main Menu window select 1. Device Config.

5 At the Device Config window select 4. TRIND.

6 At the TRIND Menu window for the Enable TRIND item, select 1. Yes to enable TRIND.
Press ENTER on the CRIND Keypad to have the selection accepted.

7 Press the CANCEL key several times until the Diagnostic Startup Menu appears.

8 At the Diagnostic Startup Menu window select 1. Main Menu.

9 At the Main Menu window select 1. CRIND Config.

10 At the CRIND Config window select CRIND ID’s.

11 At the CRIND ID’s window select 1. CRIND ID Side A for side 1, or 2. CRIND ID Side B
for side 2.
12 At the CRIND ID Side A or CRIND ID Side B window, observe and make note of the
CRIND ID. Verify that the ID value is the same as the dispenser address setup on Gateway
Board T20678-GX.
Draft
Page 14 MDE-4544 Encore S Series TRIND Retrofit Kit C00011-011 Installation Manual • January 2006

Testing the TRIND Device

Perform the following steps to test the TRIND device. For details on wire connections, refer to
“TRIND Cable Block Diagram R20775, Sheet 2” on page 13.

1 If the Site Controller is not operational, proceed to step 2. otherwise proceed to 6.

Installation
2 If the Site Controller (G-SITE
been loaded), place the unit in the “stand alone” mode.
Note: The following steps are used to place the unit in the stand alone mode. Both the Stand
Alone jumper cable and the RFID Micro Reader PCA jump jack methods are listed. The installer should select the method that is the most effective based on the type on installation that is encountered.
3 Locate the side 1 card cage cable harness and disconnect P1 of cable M00507A00X or locate
RFID Micro Reader PCA M06100A00X that’s part of the M06143A00X assembly, and place a jumper in JP3. If using the jump jack in JP3 in the RFID Micro Reader PCA proceed to step 5, if not, go to step 4.
Note: The “jump jack” method is by far the most convenient way of placing the unit in the
standalone mode. It is recommended that this method be used if at all possible.
4 Obtain Standalone Jumper Cable R20602-GX from the ASC TRIND Tool Kit, and connect the
P1/P2 end of the cable to the P1 end of M00507A00X cable for side 1. Refer to the
Cable Block Diagram R20775, Sheet 2” on page 13 for the location of M00507A00X.
Note: Connect the jumper cable to side 1 only to ensure successful standalone operation.
Jumper cable connection places both side 1 and side 2 in standalone mode.
Figure 6: Standalone Jumper Cable R20602-GX
®
or third party) is not operational (i.e., the application has not
“TRIND
Draft
P1/P2

5 Restore power to the card cage by reconnecting Power Cable M06525A001.

6 Allow about 12 seconds for the Gateway Board software to start up, then verify that the SYNC
and STAT Light Emitting Diodes (LEDs) on RFID Micro Reader PCA M06100A00X flash, and the OKT LED is illuminated.
Note: A visual of these indicators may be obtained by viewing TRIND from the front door
prior to the installation of the TRIND graphics.
MDE-4544 Encore S Series TRIND Retrofit Kit C00011-011 Installation Manual • January 2006 Page 15
Installation
7 From side 1 of the unit, point the hand held test tag (Q13630-02 from the ACS TRIND tool
kit) at the TRIND target graphic. The TRIND indicator will light when the tag is approximately 3 inches or less away for the target graphic. Repeat for side 2.
Note: If the indicator fails to light, check whether the light on other side is on; if so, it
indicates a crossing of side 1 and 2 cables. Check connections.
Figure 7: TRIND Hand Held Test Tag
POINT MUST BE WITHIN 3 INCHES OF TARGET GRAPHIC
8 Once testing has been successfully completed, remove power from the unit(s), remove the
jumper cable or jump jack from JP3, and restore power to the unit.

Completing Installation

After all testing has been completed, perform the following steps.
1 Verify that all newly installed cables and wires are properly dressed and do not obstruct CIM
Door closure.
2 Obtain FCC label nameplate M02962B007 from the kit, and install the label near the UL and
Gilbarco labels located on the inner column sheathing.
IMPORTANT!
Target Graphic
Draft

3 Close and secure all doors.

4 Install the TRIND graphics.

5 Clean up the work site, removing all materials to be discarded and all tools.

CRIND®, Encore®, G-SITE® and TRIND® are registered trademarks of Gilbarco Inc. Phillips® is a registered trademark of Phillips Screw Company. UL® is a registered trademark of Underwriters’ Laboratories.
© 2006 Gilbarco Inc. 7300 West Friendly Avenue • Post Office Box 22087 Greensboro, North Carolina 27420 Phone (336) 547-5000 • http://www.gilbarco.com • Printed in the U.S.A. MDE-4544 Encore S Series TRIND Retrofit Kit C00011-011 Installation Manual • January 2006
Loading...