GigaTera HR 85W, HR 110W, HR 150W User Manual

HR
R
85W | 110W | 150W
Product Installation & Operation User Guide
http://www.kmwgigatera.com
Installation & Operation User Guide
LED
Serious injury might result if the following precautions are not followed.
The user may be injured or there would be property damage if the instructions below are not followed.
The installation should be performed by certied workers under the relevant regulations of end user's country / region.
Never modify or disassemble LED lighting arbitrarily because it can cause serious accidents.
Never use any input power except the listed rated voltage. If not, it can cause serious accidents.
Before installation, shut off the power supply and verify it is de-powered using a measuring instrument.
The wiring should be insulated under end user's respective region's Electric Installations Standards.
Do not install in a wet environment.
This symbol is intended to remind the user the presence of actions and operation that may cause danger. Please read instructions carefully and follow the instructions to avoid any danger.
This symbol is intended to represent precautions that the user should follow to prevent danger.
Do not forcefully pull on AC/DC lines when wiring up the lighting. (It causes the wires to snap.)
Do not use this product for any purposes other than what’s specied.
The manufacturer or sellers are not responsible for breakdowns or accidents caused by its improper use.
When connecting the wires, use proper connection terminals depending on the site of installation. Do not install in a wet environment.
Make sure to ground xture by contacting it to metals around it to prevent damage by static.
The product may be damaged if static is not removed.
During the operation, be careful not to disconnect the wires.
Make sure the grounding is performed under Electricity Standards.
Using it for any voltage other than specied can cause failure or re.
Do not use it in moist environment.
Be mindful of proper ventilation of product.
Improper installation or disassembly causes a deformation or breakdown of the product.
Consider proper protection devices, such as circuit breakers, fuses, switches, etc. for safety precautions.
Do not install in an enviroment with excessive vibration.
Do not handle product with contaminated hands or gloves.
In any event, do not store / install in a contaminated place.
Changes or modications not expressly approved by the manufacturer could void the user's authority to
operate the equipment.
This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant
to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation.
If this equipment does cause harmful interference to radio or television reception, which can be
determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
- Reorient or relocate the receiving antenna.
- Increase the separation between the equipment and receiver.
- Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
- Consult the dealer or an experienced radio/TV technician for help.
WARNING
CAUTION
Safety Precautions Installation
The information in this document is subject to change without notice
Copyright 1991 ~ 2012 KMW, INC. All Rights Reserved
©
3
Document Revision V0.61 2013.01.15
Pages
R
Street Light (HR) Installation & Operation User Guide
Product OverviewProduct Features
1) Scope Overview
This manual describes how to compose, install, and operate LED streetlamps.
2) LED Streetlamp Apparatus (LED Streetlight)
A streetlamp is a lamp that is installed on the side of least four-lane roads to improve trafc safety of vehi-
cles and civilians as well as trafc efciency.
3) Usage This is a trafc safety facility not only for expressways, streets, parking lots, and industrial facilities, but also
for the safety on motorways or sidewalks. It is roughly divided into road lamps, sidewalk lamps, overbridge
lamps, and high-mast lightings. The shape varies with the road feature and the beauty concept of your city
to give you a lot of choices.
The HR product lineup is 85W, 110W, 150W and all of them are proud of their high lamp efciency over
100 lm/W. The lamp efciencies are 8,500 lm, 11,000 lm, and 15,000 lm, respectively.
The light distribution type is diversied. It supports Type II-S, Type II-M, Type III-S, Type-III-M to enable
streetlamp installation in all environments.
1) Vertically Arranged LED Module Method
HR adopted vertically arranged LED moduled unlike existing streetlamps. The vertically arranged LED mod-
ules can help to minimize the heat generating from the LED and further guarantee long life of the device in
the long run.
2) An Electronic Auto Switch Is Attached
On top of a product is installed an electronic Auto Switch. When the intensity of illumination reaches a certain
level, the lamp will be automatically turned off rst and then it will be automatically turned off while it is not
securing an illumination with sufcient intensity. In other words, it is a very convenient function to automati-
cally turn on or off the lamp without operating the switch whenever necessary.
3) Converter (SMPS) Exchange without Tools
HR adopted the Locking Lactch type to the locking device in the SMPS enclosure part to open or close the
enclosure without any tool when you are exchanging the SMPS. In addition, the internal SMPS is xed not
by bolts but not sockets for more comfortable maintenance.
4) Silver Nanoreflecting Plate
A nanoreflecting plate is expected to make effect on raising the intensity of illumination, i.e., improving the brightness
when it is used for illumination. Although we install a lamp with lower wattage than those of the other companies, we
can realize the intensity of illumination equivalent to or higher than them, eventually with more outstanding electricity-
saving effect.
The information in this document is subject to change without notice
Copyright 1991 ~ 2012 KMW, INC. All Rights Reserved
©
4
Document Revision V0.61 2013.01.15
Pages
R
Street Light (HR) Installation & Operation User Guide
Precautions before Installation
Precautions before Installation
This installation manual is based on the assumption an Electronic Auto Switch is installed to each product.
A product with an Electronic Auto Switch may look different from what it looks like in the brochure. Although, the other
parts than the Electronic Auto Switch will be installed in the same manner.
The whole HR lineup will be delivered without AC cables.
The AC power cables shall be purchased at the cost of the user but we would like to recommend the cables with the
following specifications.
AC Power Cable Specification: SJTW Outdoor Power Cable
The information in this document is subject to change without notice
Copyright 1991 ~ 2012 KMW, INC. All Rights Reserved
©
5
Document Revision V0.61 2013.01.15
Pages
R
Street Light (HR) Installation & Operation User Guide
① HR
② Converter
Detail Description
No
Item Purpose
HR
LED Streetlamp
Converter
Lamp and Brightness Sensor Power Supply Device (SMPS)
Package 1 (Standard Type)
The information in this document is subject to change without notice
Copyright 1991 ~ 2012 KMW, INC. All Rights Reserved
©
6
Document Revision V0.61 2013.01.15
Pages
R
Street Light (HR) Installation & Operation User Guide
Illumination Sensor Intensity
Detail Description
No
Item Purpose
HR
LED Streetlamp
Converter
Lamp and Brightness Sensor Power Supply Device (SMPS)
Illumination Sensor In­tensity
Surrounding Brightness Based Automatic Power On/Off Function (Photo Sensor)
Package 2 (Brightness Sending Type)
① HR
② Converter
Loading...