Gigahertz-Optik P-9710 Series, P-9710-1, P-9710-2, P-9710-4 User Manual

E 141203
Users Guide
P - 9710 series Optometer
P - 9710 - 1, P - 9710 - 2, and P - 9710 - 4
Measurement and examination devices for optical radiation detectors
Gigahertz-Optik GmbH
An der Kaelberweide 12, D-82299 Tuerkenfeld. Telephone +49 8193 93700 - 0 Telefax +49 8193 93700 - 50 info@gigahertz-optik.de www.gigahertz-optik.de
Gigahertz-Optik Inc.
5 Perry Way
Newburyport MA 01950-4009 USA Telephone:+ 978 462 1818 Telefax: + 978 462 3677 Email: b.angelo@gigahertz-optik.com Website: www.gigahertz-optik.de
Page 1
Table of contents:
1. Additional information to the operating instructions
1.1 Safety precautions
1.2 Hazard clause
1.3 Liability
1.4 Safety
1.5 Environmental conditions
1.6 Maintenance and cleaning
1.7 Guarantee
1.8 CE Conformity declaration
1.9 Review clause
1.10 Contact details
2. Device description P - 9710 optometer
2.1 Intended use
2.2 Inspection
2.3 Technical specifications P - 9710 series
2.4 Additional technical specifications P - 9710 variants
2.4.1 Optometer P - 9710 - 1
2.4.2 Optometer P - 9710 - 2
2.4.3 Optometer P - 9710 - 4
2.5 Description of the measurement ranges
2.6 Device overview
2.7 Detector interface
2.8 RS232 Interface / Analog Output
2.9 Trigger input (device variant P - 9710 - 4 only)
3. Performing measurements
3.1 Version Info
3.2 Quick start guide
3.3 P - 9710 Menu Structure
3.3.1 General information
3.3.2 Menu Overview
3.3.3 Front panel buttons
3.3.4 Menu description “Mode”
3.3.5 Menu description “Range”
3.3.6 Menu description “Detector”
3.3.7 Menu description “Offset”
3.3.8 Menu description “Reference”
3.3.9 Menu description “Substitution”
3.3.10 Menu description “Setup”
3.3.11 Menu description “Info”
3.4 Remote Interface (RS232)
Page
4
4 4 5 5 5 6 6 6 6 7
8
8 8 9
10
10 10 10 11 12 13 14 14
15
15 15 15 15 16 20 20 23 23 23 23 24 24 26 27
Page 2
4. Accessories
5. Maintenance and services
5.1 Battery
5.2 Calibration
5.3 Service addresses
A. Appendix - Measurement Modes
A.1 I-Effective A.1.1 I-Effective (Schmidt - Clausen, SC) A.1.2 I-Effective (Blondel - Rey, BR) A.2 Relative Logarithmic A.3 Pulse Energy A.3.1 Principle A.3.2 Pulse Energy Measurement
28
29
29 29 30
31
31 31 32 33 33 33 34
Page 3
Additional information to the operating instructions
1
1.1 Safety precautions
Please read this users guide carefully before using the device! Trouble-free functioning of the device as well as the operational safety can only be guar­anteed when the safety precautions and the general safety measures de­scribed in this users guide are considered.
The device should only be used for its intended purpose and according to its technical specifications. Any other use of the device is not allowed.
Immediately after unpacking and before the device start-up, the device should be inspected for any mechanical damages or loose parts. In such cases, the device should not be used.
Safety can also be impaired if the device is not functioning properly.
If during operation it is suspected that the safety has been impaired, the device should be switched off and its use by third parties ruled out.
1.2 Hazard clause
The device described in this instruction manual is designed for optical radi­ation measurements. The device offers no protection against radiation risks affiliated with the measured objects.
Persons in charge of performing measurements and using the device are obligated to read and comply with the instructions given in this users guide before beginning any measurement.
Persons in charge of performing measurements and using the device must be well informed about accident prevention regulations in their field of work.
Handling the device requires intermittent concentration of the operator on the device. The device should therefore not be used in surroundings that might lead to interrupted operator attentiveness. This possible risk must also be included in the briefing of the device operator.
Through this users guide, Gigahertz-Optik GmbH as the device manufac­turer informs the device owner about the possible hazards while using the device. The owner and the responsible device users confirm the receipt and approval of this users guide. The owner and operator of the device have been informed about the diligence required when choosing and brief­ing the device users and operators.
1.3 Liability
The responsibility for all consequences that might arise from the use of the measurement device or its accessories lies solely on the user and/or own­er.
Page 4
Gigahertz-Optik GmbH or its suppliers can under no circumstances be lia­ble for any direct or indirect business interruptions, loss of profits or data loss. This also applies to damages that may arise during the device opera­tion.
The Gigahertz-Optik GmbH Terms and Conditions of Delivery and Pay­ment generally apply.
1.4 Safety
The measurement device is designed for operation in a clean environment and within operating temperatures ranging from +5 to +40 ºC.
The measurement device or its accessories are not to be exposed to direct sunlight or moisture.
The device should be switched off and secured against unintended start-up by third parties in case of indications suggesting unsafe operating condi­tions. Such indicators include:
when the device shows visible damages
when the device contains lose parts, either internal or external
when the device is not functional
Safe operation of the device can be impaired due to one of the following circumstances:
Outdoor storage or storage in moist environment over a long period of time or other adverse conditions.
Excessive strain during transport (e.g., due to improper packaging)
Operation in aggravated environmental conditions such as high temper­atures, humidity, etc.
Operation in dangerous conditions (explosive gas, fumes, dust, etc.)
1.5 Environmental conditions
Optical measurement devices are sensitive to influences resulting from certain environmental conditions, e.g., high temperatures, humidity, and contamination, which might lead to measurement errors!
The measurement device should not be taken from a cold environment and directly put to operation in a warm surrounding. Under certain circumstanc­es, condensation could arise and negatively impact on the electrical and optical functions. Allow the device to adjust to the temperature of the sur­roundings before switching it on.
The measurement device should not be operated within high magnetic, electromagnetic or electrostatic fields.
Page 5
1.6 Maintenance and cleaning
The intervals for the recurrent recalibrations should be observed!
Opening of the device as well as device repair should only be done by au­thorized persons.
Off-the-shelf, residue-free, and non-abrasive detergents can be used for the exterior cleaning of the device.
While cleaning it should be made sure that the detergent doesn’t penetrate the interior of the device. This can lead to short circuiting or device opera­tion errors.
Do not use aggressive cleaning agents.
1.7 Guarantee
Gigahertz-Optik GmbH warrants that the product is free from material and production defects for a period of 12 months beginning from the date of delivery. In case defects are experienced within the warranty period, Giga­hertz-Optik GmbH repairs or replaces the device free of charge.
In order for the warranty to be effective, the customer should submit the product name, serial number, date of purchase as well as the description of the defect in writing to Gigahertz-Optik GmbH after which he/she will re­ceive a service number (RMA) enabling him/her to send back the device.
The user is responsible for the appropriate packaging of the device.
Shipping through the user must be done on a free to buyer’s address basis.
The guarantee does not cover consequential damages.
The Gigahertz-Optik GmbH Terms and Conditions of Delivery and Pay­ment generally apply.
1.8 CE Conformity
Gigahertz-Optik GmbH declares that the measurement device, with re­gards to its design and conception, conforms to the EG-guidelines and corresponding harmonized norms.
The CE Declaration of Conformity can be requested separately.
If any alteration is made on this machine without prior agreement this declaration loses its validity.
1.9 Review clause
Gigahertz-Optik GmbH reserves the right to changes in this users guide without prior notice.
Page 6
1.10 Contact details
Headquarters
Gigahertz-Optik GmbH Kaelberweide 12 D-82299 Tuerkenfeld
Telephone: +49 (0) 8193 93700 - 0 Telefax: +49 (0) 8193 93700 - 50 Email: info@gigahertz-optik.de Website: http://www.gigahertz-optik.de
North and South America
Gigahertz-Optik Inc.
5 Perry Way
Newburyport MA 01950-4009 USA
Telephone: + 978 462 1818 Telefax: + 978 462 3677 Email: b.angelo@gigahertz-optik.com Website: http://www.gigahertz-optik.com
Page 7
2 Device description P - 9710 optometer
2.1 Intended use
The P - 9710 optometers are measurement and examination devices for optical radiation detectors.
The device can be controlled manually via front panel buttons or via a RS232 remote interface.
Measurement results are displayed on the integrated display (LCD) or transmitted via the RS232 remote interface.
Different optical quantities or wavelength bands can be measured by using different detector heads in combination with the P - 9710 devices.
The calibration of the optical quantities is stored in the connector plug of the detector head. This allows using different detector heads with the P ­9710 device or using the detector heads with different P - 9710 devices without the need to change or transfer calibration factors manually.
The P - 9710 devices have built-in batteries that are charged with the sup­plied plug-in power supply. The capacity of the battery allows
5 hours of
operation with display illumination on and 12 hours with illumination off.
2.2 Inspection
Upon receiving your device, please check the package and all its parts for any possible damages that may have occurred during transportation.
Any transport damages should immediately be reported to the shipper.
After unpacking, please check to confirm there are no transport damages or any irregularities with regards to package completeness and correct­ness. The scope of delivery contains:
one measurement device P - 9710
one power supply
a factory calibration certificate
this users guide
one hard-top casing (optional)
one serial interface cable (optional)
different measurement heads and their calibration certificate (optional)
Page 8
2 Device description P - 9710 optometer
2.3 Technical specifications P - 9710 series Power supply
Display
Detector interface Analog output
Units of measurement
Signal amplifier
CW integration time Pulse integration time Offset correction
built-in lead acid battery, 6V / 0.5Ah (Version before
2017) Built-in lithium Ion battery, 3.7V /1400mAh (Version
2017) operating time: 5hr / 12hr with backlight on /off plug 5.5mm/2.5mm/9.5mm for external power supply (7.5VDC - 8.0VDC / min. 250mA)
alphanumeric LCD, 2 rows x 16 chars character height 5mm LED backlight (on / off)
9pin DSUB (female) output voltage proportional to detector input current
connector: TRIAD01 5pin (Tyco)
Amperes (absolute calibration) optical units corresponding to calibration data ratio in percent, logarithmic, and as factor
Transimpedance amplifier 8 ranges (200pA to 2mA) fixed range or autorange
100µs - 5.9999s 10ms - 199.99s correction range transcending
Parameter adjustment
Optical calibration data
Data logger
Front panel control Remote interface
front panel keys or remote control adjusted values permanently stored in EEPROM 10 different overall settings can be stored
stored in detector head connector (EEPROM) max. 250 calibration table entries interpolation between wavelength points possible manual input of a calibration factor possible
max. 12288 entries, permanently stored in flash memory
10 buttons, menu system RS232 (9600 Baud, 8 Data Bits, 1 Stop Bit, No
Parity) Connector: TRIAD01 (Tyco)
Page 9
2 Device description P - 9710 optometer
Temperature range
Size / weight
RoHS
2.4 Additional technical specifications P - 9710 variants
2.4.1 Optometer P - 9710 - 1 Amplifier slew rate
2.4.2 Optometer P - 9710 - 2 Amplifier slew rate
2.4.3 Optometer P - 9710 - 4 Amplifier slew rate Trigger input
operating: 5°C to 40°C storage: -10°C to 50° C
195mm x 100mm x 40mm / 500g
compatible
2ms - 10ms
20ms
20ms starts pulse energy measurement
BNC (female) low active internal pull-up (22 kOhm to +5V)
Page 10
2 Device description P - 9710 optometer
2.5 Description of the measurement ranges
Page 11
2 Device description P - 9710 optometer
2.6 Device overview
P - 9710
Display
Front panel with 10 buttons
Page 12
RS232 interface / analog output
plug for power supply
detector interface
Loading...
+ 25 hidden pages