Gigabyte 6NR152Z32MR-00 User Manual

R152-Z30 R152-Z31 R152-Z32
AMD® EPYCTM 7002 series Processor Server
Service Guide
Rev. 1.0
© 2019 GIGA-BYTE TECHNOLOGY CO., LTD. All rights reserved. The trademarks mentioned in this manual are legally registered to their respective owners.
Disclaimer
Information in this manual is protected by copyright laws and is the property of GIGABYTE.
Changes to the specications and features in this manual may be made by GIGABYTE without
prior notice. No part of this manual may be reproduced, copied, translated, transmitted, or pub­lished in any form or by any means without GIGABYTE's prior written permission.
Documentation Classications
In order to assist in the use of this product, GIGABYTE provides the following types of documentations:
 For detailed product information, carefully read the User's Manual.
For More Information
For related product specications, the latest rmware and software, and related information, please visit
our website at:
http://www.gigabyte.com
For GIGABYTE distributors and resellers, additional sales & marketing materials are available from our reseller portal:
http://reseller.b2b.gigabyte.com
For further information & technical assistance, please contact your GIGABYTE sales representative. You may also message GIGABYTE server directly by email, Facebook or twitter
Email: server.grp@gigabyte.com
Facebook: https://www.facebook.com/gigabyteserver
Twitter: https://twitter.com/GIGABYTEServer
Conventions
The following conventions are used in this user's guide:
NOTE!
Gives bits and pieces of additional
information related to the current topic.
CAUTION!
Gives precautionary measures to
avoid possible hardware or software problems.
WARNING!
Alerts you to any damage that might
result from doing or not doing specic actions.
Server Warnings and Cautions
Before installing a server, be sure that you understand the following warnings and cautions.
WARNING!
To reduce the risk of electric shock or damage to the equipment:
Do not disable the power cord grounding plug. The grounding plug is an important safety feature.
Plug the power cord into a grounded (earthed) electrical outlet that is easily accessible at all times.
Unplug the power cord from the power supply to disconnect power to the equipment.
Do not route the power cord where it can be walked on or pinched by items placed against it.
Pay particular attention to the plug, electrical outlet, and the point where the cord extends from the server.
WARNING!
To reduce the risk of personal injury from hot surfaces, allow the drives and the internal system components to cool before touching them.
WARNING!
This server is equipped with high speed fans. Keep away from hazardous moving fan blades during servicing.
CAUTION!
Do not operate the server for long periods with the access panel open or removed. Operat- ing the server in this manner results in improper airow and improper cooling that can lead to
thermal damage.
Danger of explosion if battery is incorrectly replaced.
Replace only with the same or equivalent type recommended by the manufacturer.
Dispose of used batteries according to the manufacturer’s instructions.
Electrostatic Discharge (ESD)
CAUTION!
ESD CAN DAMAGE DRIVES, BOARDS, AND OTHER PARTS. WE RECOMMEND THAT YOU PERFORM ALL PROCEDURES AT AN ESD WORKSTATION. IF ONE IS NOT AVAILABLE, PROVIDE SOME ESD PROTECTION BY WEARING AN ANTI-STATIC WRIST STRAP AT­TACHED TO CHASSIS GROUND -- ANY UNPAINTED METAL SURFACE -- ON YOUR SERVER WHEN HANDLING PARTS.
Always handle boards carefully. They can be extremely sensitive to ESD. Hold boards only by their edges without any component and pin touching. After removing a board from its protective wrapper or from the system, place the board component side up on a grounded, static free sur­face. Use a conductive foam pad if available but not the board wrapper. Do not slide board over any surface.
System power on/off:
rack. Make sure the system is removed from the rack before opening the chassis, adding, or removing any non hot-plug components.
Hazardous conditions, devices and cables:
present on power, telephone, and communication cables. Turn off the system and discon-nect the cables attached to the system before servicing it. Otherwise, personal injury or equipment damage can result.
Electrostatic discharge (ESD) and ESD protection:
boards, and other parts. We recommend that you perform all procedures in this chapter only at an ESD workstation. If one is not available, provide some ESD protection by wearing an antistatic wrist strap attached to chassis ground (any unpainted metal surface on the server) when handling parts.
ESD and handling boards:
sensi-tive to electrostatic discharge (ESD). Hold boards only by their edges. After removing a board from its protective wrapper or from the system, place the board component side up on a grounded, static free surface. Use a conductive foam pad if available but not the board wrapper. Do not slide board over any surface.
Installing or removing jumpers:
over two jumper pins. Some jumpers have a small tab on top that can be gripped with n-gertips or with a pair of ne needle nosed pliers. If the jumpers do not have such a tab, take care when
using needle nosed pliers to remove or install a jumper; grip the narrow sides of the jumper with the pliers, never the wide sides. Gripping the wide sides can dam-age the contacts inside the jumper, causing intermittent problems with the function con-trolled by that jumper. Take care to grip with, but not squeeze, the pliers or other tool used to remove a jumper, or the pins on the board may bend or break.
To remove power from system, you must remove the system from
Hazardous electrical conditions may be
ESD can damage drives,
Always handle boards carefully. They can be extremely
A jumper is a small plastic encased conductor that slips
CAUTION!
Risk of explosion if battery is replaced incorrectly or with an incorrect type. Replace the battery only with the same or equivalent type recommended by the manufacturer. Dispose of used bat­teries according to the manufacturer’s instructions.
Table of Contents
Chapter 1 Hardware Installation ................................................................................... 11
1-1 Installation Precautions .................................................................................. 11
1-2 Product Specications .................................................................................... 12
1-3 System Block Diagram ................................................................................... 15
Chapter 2 System Appearance ..................................................................................... 17
2-1 Front View ...................................................................................................... 17
2-2 Rear View ....................................................................................................... 17
2-3 Front Panel LED and Buttons ........................................................................ 18
2-4 Rear System LAN LEDs ................................................................................. 20
2-5 Hard Disk Drive LEDs .................................................................................... 21
Chapter 3 System Hardware Installation ......................................................................23
3-1 Removing Chassis Cover ............................................................................... 24
3-2 Removing and Installing the Fan Duct ........................................................... 25
3-3 Installing the CPU and Heat Sink ................................................................... 26
3-4 Installing the Memory ..................................................................................... 28
3-4-1 Eight Channel Memory Conguration .....................................................................28
3-4-2 Installing a Memory ...............................................................................................29
3-4-3 DIMM Population Table ..........................................................................................29
3-5 Installing the PCI Expansion Card ................................................................. 31
3-6 Installing the Hard Disk Drive ......................................................................... 33
3-7 Installing the Mezzanine Card (Optional) ....................................................... 35
3-8 Replacing the FAN Assemblly ........................................................................ 36
3-9 Replacing the Power Supply .......................................................................... 37
3-10 Installing the Mezzanine Card (Optional) ....................................................... 38
3-11 Cable Routing ................................................................................................39
3-11-1 R152-Z30 Cable Routing ........................................................................................39
3-11-2 R152-Z31 Cable Routing ........................................................................................41
3-11-3 R152-Z32 Cable Routing ........................................................................................43
Chapter 4 Motherboard Components ...........................................................................47
4-1 Motherboard Components ............................................................................. 47
4-2 Jumper Settings ............................................................................................. 49
Chapter 1 BIOS Setup .................................................................................................. 51
5-1 The Main Menu .............................................................................................. 53
5-2 Advanced Menu ............................................................................................. 55
- 7 -
5-2-1 Trusted Computing .................................................................................................56
5-2-2 PSP Firmware Versions ..........................................................................................57
5-2-3 Legacy Video Select ...............................................................................................58
5-2-4 AST2500 Super IO Conguration ...........................................................................59
5-2-5 S5 RTC Wake Settings ...........................................................................................62
5-2-6 Serial Port Console Redirection .............................................................................63
5-2-7 CPU Conguration ..................................................................................................65
5-2-8 PCI Subsystem .......................................................................................................67
5-2-9 USB Conguration ..................................................................................................69
5-2-10 NVMe Conguration ...............................................................................................71
5-2-11 SATA Conguration.................................................................................................72
5-2-12 Network Stack ........................................................................................................73
5-2-13 AMD Mem Conguration Status .............................................................................74
5-2-14 iSCSI Conguration ................................................................................................75
5-2-15 Tls Auth Conguration ............................................................................................76
5-2-16 AVAGO MegaRAID Conguration Utility ................................................................77
5-2-17 Intel(R) I350 Gigabit Network Connection ..............................................................79
5-2-18 VLAN Conguration ................................................................................................81
5-2-19 MAC IPv4 Network Conguration ...........................................................................83
5-2-20 MAC IPv6 Network Conguration ...........................................................................84
5-3 AMD CBS Menu ............................................................................................. 85
5-3-1 Valhalla Common Options ......................................................................................86
5-3-2 DF Common Options ..............................................................................................88
5-3-3 UMC Common Options ..........................................................................................89
5-3-4 NBIO Common Options ..........................................................................................94
5-3-5 FCH Common Options ...........................................................................................95
5-3-6 NTB Common Options ...........................................................................................96
5-3-7 SOC Miscellaneous Control ...................................................................................97
5-4 AMD PBS Option Menu ................................................................................. 98
5-4-1 RAS ........................................................................................................................99
5-5 Chipset Setup Menu ..................................................................................... 101
5-5-1 North Bridge .........................................................................................................102
5-6 Server Management Menu ........................................................................... 103
5-6-1 System Event Log ................................................................................................105
5-6-2 View FRU Information ..........................................................................................106
5-6-3 BMC Network Conguration .................................................................................107
5-6-4 IPv6 BMC Network Conguration .........................................................................108
5-7 Security Menu .............................................................................................. 109
5-7-1 Secure Boot ..........................................................................................................11 0
5-8 Boot Menu .................................................................................................... 112
5-9 Save & Exit Menu ......................................................................................... 114
- 8 -
5-10 ABL POST Codes ........................................................................................ 115
5-10-1 StartProcessorTestPoints .....................................................................................11 5
5-10-2 Memory test points ...............................................................................................11 5
5-10-3 PMU Test Points ...................................................................................................115
5-10-4 Original Post Code ...............................................................................................11 6
5-10-5 CPU test points .....................................................................................................11 7
5-10-6 Topology test points ..............................................................................................11 7
5-10-7 Extended memory test point .................................................................................11 7
5-10-8 Gnb Earlier init ......................................................................................................11 8
5-10-9 PMU test points ....................................................................................................121
5-10-10 ABL0 test points ...................................................................................................121
5-10-11 ABL5 test points ...................................................................................................121
5-11 Agesa POST Codes ..................................................................................... 125
5-11-1 Universal Post Code .............................................................................................125
5-11-2 [0xA1XX] For CZ only memory Postcodes ...........................................................125
5-11-3 S3 Interface Post Code ........................................................................................128
5-11-4 PMU Post Code ....................................................................................................128
5-11-5 [0xA5XX] assigned for AGESA PSP Module ........................................................128
5-11-6 [0xA9XX, 0xAAXX] assigned for AGESA NBIO Module .......................................131
5-11-7 [0xACXX] assigned for AGESA CCX Module .......................................................133
5-11-8 [0xADXX] assigned for AGESA DF Module ..........................................................134
5-11-9 [0xAFXX] assigned for AGESA FCH Module ........................................................134
5-12 BIOS POST Beep code (AMI standard) ....................................................... 136
5-12-1 PEI Beep Codes ...................................................................................................136
5-12-2 DXE Beep Codes .................................................................................................136
5-13 BIOS Recovery Instruction ........................................................................... 137
- 9 -
This page intentionally left blank
- 10 -
Chapter 1 Hardware Installation
1-1 Installation Precautions
The motherboard/system contain numerous delicate electronic circuits and components which can become damaged as a result of electrostatic discharge (ESD). Prior to installation, carefully read the service guide and follow these procedures:
• Prior to installation, do not remove or break motherboard S/N (Serial Number) sticker or
warranty sticker provided by your dealer. These stickers are required for warranty validation.
• Always remove the AC power by unplugging the power cord from the power outlet before
installing or removing the motherboard or other hardware components.
• When connecting hardware components to the internal connectors on the motherboard,
make sure they are connected tightly and securely.
• When handling the motherboard, avoid touching any metal leads or connectors.
• It is best to wear an electrostatic discharge (ESD) wrist strap when handling electronic
components such as a motherboard, CPU or memory. If you do not have an ESD wrist
strap, keep your hands dry and rst touch a metal object to eliminate static electricity.
• Prior to installing the motherboard, please have it on top of an antistatic pad or within an
electrostatic shielding container.
• Before unplugging the power supply cable from the motherboard, make sure the power
supply has been turned off.
• Before turning on the power, make sure the power supply voltage has been set according to
the local voltage standard.
• Before using the product, please verify that all cables and power connectors of your
hardware components are connected.
• To prevent damage to the motherboard, do not allow screws to come in contact with the
motherboard circuit or its components.
• Make sure there are no leftover screws or metal components placed on the motherboard or
within the computer casing.
• Do not place the computer system on an uneven surface
• Do not place the computer system in a high-temperature environment.
• Turning on the computer power during the installation process can lead to damage to
system components as well as physical harm to the user.
• If you are uncertain about any installation steps or have a problem related to the use of the
product, please consult a certied computer technician.
.
- 11 - Hardware Installation
1-2 Product Specications
CPU  AMD EPYC™ 7002 series processor family
 Single processor, 7nm, Socket SP3  Up to 64-core, 128 threads  NOTE: If only 1 CPU is installed, some PCIe or memory functions might be
unavailable.
Chipset
Memory  16 x DIMM slots
LAN  2 x 1Gb/s LAN ports (Intel® I350)
Expansion Slot  1 x Riser card:
Video  Integrated in Aspeed® AST2500
Storage (R12-Z30)
(R152-Z 31)  8 x 2.5" SAS/SATA, 2 x 2.5" U.2 hot-swappable HDD/SSD bays
(R152-Z32)  10 x 2.5" U.2 hot-swappable HDD/SSD bays
 System on Chip
 DDR4 memory supported only  8-channel memory architecture  RDIMM modules up to 64GB supported  LRDIMM modules up to 128GB suppor ted  Memory speed: Up to 3200 MHz w/1DPC, 2933MHz w/2DPC
 1 x 10/100/1000 management LAN
 - 1 x CRS101D  * 1 x Full-height half-length slot with PCIe x16 (Gen4 x16 bus) slot
 1 x OCP mezzanine slots with PCIe Gen3 x16 bandwidth (Type1, P1, P2, P3,
P4; Type2 P5 with NCSI suppor ted)
 2 x M.2 slot:  - M-key  - PCIe Gen3 x4  - Supports NGFF-2242/2260/2280 cards
 2D Video Graphic Adapter with PCIe bus interface  1920x1200@60Hz 32bpp, DDR4 SDR AM
 4 x 3.5" SAS/SATA hot-swappable HDD/SSD bays  SAS card is required for SAS devices support
 SAS card is required for SAS devices support
SAS  Supported via add-on SAS Card
Hardware Installation - 12 -
Front Panel LED/Buttons (R152-Z30)
(R152-Z31) (R152-Z32)
Rear Panel I/O  3 x USB 3.0
Backplane I/O (R152-Z30)
(R152-Z 31) (R152-Z32)
TPM  1 x TPM header with SPI interface
System Management
 2 x USB 3.0  1 x Power button with LED  1 x ID button with LED  1 x NMI button  1 x Reset button  2 x LAN activity LEDs  1 x HDD activity LED  1 x System status LED
 1 x USB 3.0  1 x Power button with LED  1 x ID button with LED  1 x NMI button  1 x Reset button  2 x LAN activity LEDs  1 x HDD activity LED  1 x System status LED
 1 x VGA  2 x RJ45  1 x MLAN  1 x ID button with LED
 SATA(6Gb/s)
 SAS(12Gb/s) / SATA(6Gb/s)/ NVMe(8Gb/s)
 Optional TPM2.0 kit: CTM010  Aspeed® AST2500 management controller  Avocent® MergePoint IPMI 2.0 web interface:  Network settings  Network security settings  Hardware information  Users control  Services settings  IPMI settings  Sessions control  LDAP settings  Power control Fan proles  Voltages, fans and temperatures monitoring  System event log  Events management (platform events, trap settings, email settings)  Serial Over LAN  vKVM & vMedia (HTML5)
- 13 - Hardware Installation
Power Supply
(R152-Z30)
 2 x 650W redundant PSUs  80 PLUS Platinum
(R152-Z 31)
 AC Input:  - 100-240V/ 12-7A, 50-60Hz  - 200-240V/ 7A, 50- 60Hz
 DC Output:  - 1200W  - 12V, 80.5A (100-240V)  - 12V, 97A (200-240V)  - 12Vsb, 3A
(R152-Z32)  2 x 850W redundant PSUs
 80 PLUS Platinum  AC Input:  - 100-240V/ 12-7A, 50-60Hz  - 200-240V/ 7A, 50- 60Hz  DC Output:  - 1200W  - 12V, 80.5A (100-240V)  - 12V, 97A (200-240V)  - 12Vsb, 3A
Environment
Ambient
 Operating temperature: 10°C to 35°C  Non-operating temperature: -40°C to 60°C
Temperature
 Operating humidity: 8-80% (non-condensing)
Relative
 Non-operating humidity: 20%-95% (non-condensing)
Humidity System
Dimension
* We reserves the right to make any changes to the product specications and product-related information without
prior notice.
 1U
 438mm (W) x 43.5mm (H) x 730mm (D)
Hardware Installation - 14 -
1-3 System Block Diagram
R152-Z 30
R152-Z 31
R152-Z 32
- 15 - Hardware Installation
This page intentionally left blank
Hardware Installation - 16 -
Chapter 2 System Appearance
1
2
2-1 Front View
1 2
R152-Z30
HDD#0 HDD#1 HDD#2 HDD#3
R152-Z31
R152-Z32
No. Description
• Please Go to Chapter
LEDs.
2-2 Rear View
No. Description
HDD#2 HDD#3
HDD#2 HDD#3
Front Panel LEDs and buttons
1
1.
HDD#0 HDD#1
2
HDD#0 HDD#1
HDD#4 HDD#5
HDD#4 HDD#5
HDD#6 HDD#7
HDD#6 HDD#7
HDD#8 HDD#9
HDD#8 HDD#9
2. Front USB 3.0 Port
Orange HDD Latches Support NVMe
2-3 Front Panel LED
PSU1PSU2
21 3
and Buttons for detail description of function
9
546 7 8
1. Serial Port
2. VGA Port
3. Mezzanine Card Slot (Option/OCP V2.0 Card)
4. 10/100/1000 Server management LAN port
5. ID Button
6. USB 3.0 Port x 2
7. GbE LAN Port x 2
8. USB 3.0 Port
9. PCIe Card Slot
- 17 - System Appearance
2-3 Front Panel LED and Buttons
R52-Z30
NMI
RST
L1
L2 SYS
2 3 4 5 6
1
No. Name Color Status Description
Press the button server generates a NMI to the processor
1.
NMI button
2.
Reset Button Press the button to reset the system.
LAN 1/2
3/4
Active/Link
LEDs
HDD Status
5.
LED
System
6.
Status LED
7.
ID Button Press the button to activate system identication
Power button
8.
with LED
Green Solid On Link between system and network or no access.
Green Blink Data trasmission or receiving is occuring
N/A Off No data transmission or receiving is occuring
Green
Amber On HDD fault
Green/
Amber
N/A Off No HDD access or no HDD fault.
Green Solid On System is operating normally.
Solid On
Amber
N/A Off
Green On System is powered on
Green Blink System is in ACPI S1 state (sleep mode)
N/A Off
if the multiple-bit ECC errors occur, which effectively halt
the server.
On HDD locate
Blink HDD access
Blink HDD rebuilding
Critical condition, may indicate:
System fan failure
System temperature Non-critical condition, may indicate:
Redundant power module failure
Blink
Temperature and voltage issue
Chassis intrusion System is not ready, may indicate:
POST error
NMI error
Processor or terminator missing
System is not powered on or in ACPI S5 state
System is in ACPI S4 state (hibernate mode)
ID
7 8
(power off)
System Appearance - 18 -
R152-Z31
R152-Z32
1
3
5
7
L1 L2
2
4
6
8
No. Name Color Status Description
1.
Reset Button Press the button to reset the system.
Press the button server generates a NMI to the processor
2.
NMI button
Green On System is powered on
3.
Power button
with LED
Green Blink System is in ACPI S1 state (sleep mode)
N/A Off
4.
ID Button Press the button to activate system identication
Green
5.
HDD Status LED
Amber On HDD fault
Green/
Amber
N/A Off No HDD access or no HDD fault.
Green Solid On System is operating normally.
Solid On
Amber
System
6.
Status LED
N/A Off
Green Solid On Link between system and network or no access.
Green Blink Data trasmission or receiving is occuring
N/A Off No data transmission or receiving is occuring
7/8.
LAN 1/2
Active/Link
LEDs
if the multiple-bit ECC errors occur, which effectively halt
the server.
System is not powered on or in ACPI S5 state
(power off)
System is in ACPI S4 state (hibernate mode)
On HDD locate
Blink HDD access
Blink HDD rebuilding
Critical condition, may indicate:
System fan failure
System temperature Non-critical condition, may indicate:
Redundant power module failure
Blink
Temperature and voltage issue
Chassis intrusion System is not ready, may indicate:
POST error
NMI error
Processor or terminator missing
- 19 - System Appearance
2-4 Rear System LAN LEDs
1 2
1 2
1 2
No. Name Color Status Description
Yel low On 1 Gbps data rate
Green On 100 Mbps data rate
N/A Off 10 Mbps data rate
On Link between system and
Green
network or no access
Blink Data transmission or receiving is occurring
N/A Off No data transmission or
receiving is occurring
1.
2.
1GbE Speed LED
1GbE Link/ Activity LED
System Appearance - 20 -
2-5 Hard Disk Drive LEDs
R152-Z30
R152-Z31
R152-Z32
RAID SKU
Disk LED (LED on
No RAID configuration
(via HBA)
RAID configuration
(via HW RAID Card or
SW RAID Card)
LED 2
Green
Back Panel)
Removed HDD Slot
(LED on Back Panel)
Disk LED
Removed HDD Slot
HDD Present No HDD
ON
NOTE:
*1: Depends on HBA/Utility Spec.
*2: Blink cycle depends on HDD's activity signal.
*3: If HDD is pulled out during rebuilding, the disk status of this HDD is regarded as faulty.
LED1
Locate
ON(*1)
Green
Amber
ON(*1) OFF --
Green
Amber
Green
Amber
ON(*1)
Green
Amber
OFF
OFF
OFF
ON
OFF
OFF
/(' /('
HDD Fault
OFF
OFF
OFF
OFF
ON
OFF
ON
/(' /('
Rebuilding
(Low Speed: 2 Hz)
(*3)
(*3)
HDD
Access
BLINK (*2)
OFF
--
--
BLINK (*2)
OFF
--
--
HDD Present
(No Access)
OFF
OFF
--
OFF
OFF
--
--
- 21 - System Appearance
This page intentionally left blank
System Appearance - 22 -
Chapter 3 System Hardware Installation
Pre-installation Instructions
Computer components and electronic circuit boards can be damaged by discharges of static electricity. Working on computers that are still connected to a power supply can be extremely dangerous. Follow the simple guidelines below to avoid damage to your computer or injury to yourself.
• Always disconnect the computer from the power outlet whenever you are working inside the
computer case.
• If possible, wear a grounded wrist strap when you are working inside the computer case.
Alternatively, discharge any static electricity by touching the bare metal system of the computer case, or the bare metal body of any other grounded appliance.
• Hold electronic circuit boards by the edges only. Do not touch the components on the board unless it is necessary to do so. Do not ex or stress the circuit board.
• Leave all components inside the static-proof packaging until you are ready to use the component
for the installation.
- 23 - System Hardware Installation
3-1 Removing Chassis Cover
Before you remove or install the system cover
• Make sure the system is not turned on or connected to AC power.
Follow these instructions to remove the rear system cover:
1. Loosen and remove the thumbscrew securing the back cover.
2. Push down the indentation located at the side of the back chassis
3. Slide the cover horizontally to the back and remove the cover in the direction of the arrow.
1
4
3
2
Follow these instructions to remove the front system cover:
1. Remove the ve screws securing the front system cover to the system.
2. Flip open the front system cover.
1
4
3
2
System Hardware Installation - 24 -
3-2 Removing and Installing the Fan Duct
Follow these instructions to remove/install the fan duct:
1. Lift up to remove the two fan ducts
2. To install the fan duct, align the fan duct with the guiding groove. Push down the fan duct into
chassis until its rmly seats
R152-Z30
R152-Z31/R152-Z32
2
1
2
1
- 25 - System Hardware Installation
3-3 Installing the CPU and Heat Sink
External cap
Read the following guidelines before you begin to install the CPU:
• Make sure that the motherboard supports the CPU.
• Always turn off the computer and unplug the power cord from the power outlet before installing
the CPU to prevent hardware damage.
• Unplug all cables from the power outlets.
• Disconnect all telecommunication cables from their ports.
• Place the system unit on a at and stable surface.
• Open the system according to the instructions.
WARNING!
Failure to properly turn off the server before you start installing components may cause serious damage. Do not attempt the procedures described in the following sections unless you are a
qualied service technician.
Follow these instructions to install the CPU:
1. Align and install the processor on the carrier, making sure to line up the triangle markers on the corner of the CPU to the triangle mark on the corner of the CPU carrier.
2. Slide the carrier assembly into the channels of the carrier bracket
3. Close the carrier bracket so that it rmly latches on to the CPU socket.
4. Close the CPU socket cover.
5. Tighten and secure the CPU socket cover screws in the following order (3g2g1).
NOTE:
NOTE:
the underside of the heat sink.
6. Align and place the heatsink onto the top of the CPU socket.
7. To secure the heatsink, tighten the four screws to the CPU socket.
8. Repeat steps 1-7 for the second CPU and heatsink.
9. To remove the heatsinks and CPUs, follow steps 1-7 in reverse order.
When removing the CPU socket cover, loosen the screws in reverse order (1g2g3). Apply thermal compound evenly on the top of the CPU. Remove the protective cover from
1
2
3
System Hardware Installation - 26 -
3
1
2
CPU
4
6
4
5
7
2
2
3
3
1
9
1
8
8
9
- 27 - System Hardware Installation
3-4 Installing the Memory
Read the following guidelines before you begin to install the memory:
• Make sure that the motherboard supports the memory. It is recommended that memory of the
same capacity, brand, speed, and chips be used.
• Always turn off the computer and unplug the power cord from the power outlet before installing
the memory to prevent hardware damage.
• Memory modules have a foolproof design. A memory module can be installed in only one
direction. If you are unable to insert the memory, switch the direction.
3- 4-1 Eight Channel Memory Conguration
This motherboard provides 16 DDR4 memory sockets and supports Eight Channel Technology. After the memory is installed, the BIOS will automatically detect the specifications and capacity of the memory. Enabling Four Channel memory mode will be four times of the original memory bandwidth.
DIMM_P0_G0
DIMM_P0_G1
DIMM_P0_H0
DIMM_P0_H1
DIMM_P0_E0
DIMM_P0_E1
DIMM_P0_F0
DIMM_P0_F1
System Hardware Installation - 28 -
CPU
DIMM_P0_A1
DIMM_P0_A0
DIMM_P0_B0
DIMM_P0_B1
DIMM_P0_D0
DIMM_P0_D1
DIMM_P0_C0
DIMM_P0_C1
3-4-2 Installing a Memory
Before installing a memory module, make sure to turn off the computer and unplug the power cord from the power outlet to prevent damage to the memory module. Be sure to install DDR4 DIMMs on this motherboard.
Follow these instructions to install the Memory:
1. Insert the DIMM memory module vertically into the DIMM slot, and push it down.
2. Close the plastic clip at both edges of the DIMM slots to lock the DIMM module.
3. Reverse the installation steps when you want to remove the DIMM module.
2
1
2
3-4-3 DIMM Population Table
RDIMM Maximum Frequency Supported Tablel
DIMMs
Populated
1
2
1R
1
--
2 1
--
DIMM
2R
Frequency (MT/s)
1.2V
2DR
--
1
--
1 2
- 29 - System Hardware Installation
3200 3200 2933 2933 2933
LRDIMM Maximum Frequency Supported Table
DIMM
DIMMs
Populated
1
2S2R 2S4R
4DR
1
--
2
2
1
--
3DS RDIMM Maximum Frequency Supported Table
DIMM
DIMMs
Populated
1 2
2S2R 2S4R
1
2
Frequency (MT/s)
--
1
--
1 2
Frequency (MT/s)
1.2V
3200 3200 2933
Not Supported
2933
1.2V
2933 2666
NOTE!
1R: 1 package rank of SDP DRAMs
l
2R: 2 package rank of SDP DRAMs
l
2DR: 2 package rank of DDP DRAMs
l
4DR: 4 package rank of DDP DRAMs
l
2S2R/2S4R/2S8R: 2 package rank of 2/4/8 high 3DS DRAMs
l
DIMM must be populated in sequential alphabetic order,
l
starting with bank A.
When only one DIMM is used, it must be populated in memory slot A1.
l
System Hardware Installation - 30 -
Loading...