... for prototyping and small batch production of printed circuit boards
Etching Device 1
Etching Device 2
Etching Devices 1 and 2 are used in laboratories and small batch production for making printed
circuit boards as well as for etching metal folies.
The cuvettes are out of cristal clear acrylic glass. They are mounted at a plastic tube in which the
membrane pump is mounted. Further the etching device includes the glass heater for heating up
the etchand temperature up to 45°C, a PCB-holder for carrying the printed circuit boards while
etching and a thermometer.
During etching the boards, the membrane pump blows air in the air curtain tube which is mounted
at the bottom of the tank. Outcome of this, small air bubbles are inside the etchand and reduces the
etching time.
Super slim acrylic glass tank
¢
Membran pump and air curtain tube inside the tank
¢
for producing small air bubbles inside the etchand
Adjustable heater (glass-heater),Temperature range
¢
nearly +36°C to +45°C
Adjustable PCB holder to carry circuit boards of
¢
various sizes
Glass thermometer
¢
Plastic drip tray
¢
Dimension (LxWxH)
¢
- Etching device 1285 x 105x 320mm
- Etching device 2445 x 105 x 320mm
Technische Änderungen vorbehalten
Gie-Tec GmbH An der Schlierbach 18 D-36132 Eiterfeld Tel.: +49 (0)6672/919-910 E-Mail:info@gie-tec.de
l
l
Technical data
Part number
Top opening
max. board size
Capacity of the tank
Heater
PCB holder
Etching sulphate needed
l
141030 1001141040 1001
210 x 25 mm365 x 25 mm
235 x 170 mm235 x 330 mm
1,75 l2,25 l
150 W150 W
single slot
2,2 kgWeight2,8 kg
400 g
l
double slot
600 g
www.gie-tec.de
gie - tec
ACHTUNG!
l
Etching device 1 and 2 can be used for
etching printed circuit boards and metal
foils of various sizes.
Any other use of the device is not
permitted.
l
The device is designed for power
supply AC 230V (50- 60Hz) and may
used only in perfect technical
condition.
Using the etching device it is not
allowed by children and people which
are not instructed.
l
The basis of the etching device (table,
work bench) is supposed to be
horizontally, stable, resistant to
chemicals and easy to clean.
The area in which the devices are used
should be well illuminated and
ventilatable.
Not required tools, devices or
components are to be kept away from
the working area.
l
Eating, drinking and smoking are
strictly prohibited!
l
Keep devices and chemicals out of
the range of children and foods.
Store not required chemicals in the
original container in a dry place.
l
Assembly and using of the device has
to be done only according the
declaration of conformity.
l
Carry corresponding protective clothing
(acid and alkal-proof protection gloves,
protective goggles, overall or apron)
when applying the bath or when working
with the device.
l
The device must not exposed to high
humidity, strong vibrations or explosive
gas.
l
Keep this manual careful. Personal
working with this equipment are to be
instructed about the dangers.
If you don´t provide this manual, loss
of property, risk of injury may can
happen.
l
Pay attention to the disposal remaks for
waste materials.
GEFAHR!
1. Start-up
1.1 Placement
The etching device will be delivered mounted completely. Only the glass
heater and the thermometer has to plug in into the holes at the top of the tank.
Place the etching device into the catch basin. Place the device on a horizontal,
stable and acid-proof basis (e. g. tiled table).
The working area should be ventilatable and well illuminated!
1.2 Assembly
1. Place the etching device into the catch
basin (1). Place the device on a
horizontal, stable and acid-proof basis.
2. Plug in the glass heater(2) into the hole,
top of the tank
3. Fill water into the tank (4) (see technical
data). Please note: The water level
should about 2-3 cm below the maximum
high of the cuvette.
4. Connect the membrane pump (5) to
power supply (AC 230V /50-60Hz).
Please check, if small air bubbles are
comming out of the air cusion tube (3),
which is laying inside the glass acrylic
tank.
5. Thermometer (6)
6. Board holder (7)
7. Safety valve (8)
1.3 Handling of the board holder
You can adjust the board holder by
loosening the screws (8) below the handle
strip.
In case of one-sided boards, you can double
the holding capacity by clambing the boards
back-to-back.
If you do not tighten the screws, you can also shift the strips without
having to operate the screws.
For larger boards, remove the middle strip.
7
4
3
8
1.4 Etching bath
For etching, we recommend only our sodium persulfate. This etching mediums
is odorless, clear, and pollutes the device only insignificantly.
Further sodium persulfate has the positive feature to get blue if solution is
saturated.
It achives etching times of 6-8 minutes at 40-45°C. The etching speed lies
between 4 and 7 µm/min with a copper reception of approx.: 30g/l. The batch
amount ist 200 - 250 g/l of water.
- Unplug all mains plugs before filling in the etching sulfate.
- Fill water into the tanks (see technical data) and then pour the etching
sulfate into the water.
- Place the borad holder into the tank as a cover
- Connect the membrane pump and the glass heater to mains again.
8
62
5
1
www.gie-tec.de
Gie-Tec GmbH An der Schlierbach 18 D-36132 Eiterfeld Tel.: +49 (0)6672/919-910 E-Mail:info@gie-tec.de
l
In case of using other etching chemicals, we can not take over any
guarantee for the function of the device since these chemicals may
disolve the glue of the glass cuvette.
Technische Änderungen vorbehalten
l
l
l
1.5 Adjusting the heating regulator
1. Switch-on the glass heater only when the tank is filled
and the pump is activated!
2. The water level should be a few millimeters
above the marking of the heating rod so the
heater regulation can work correctly.
3. Do not heat the bath to a temperature above 50°C
since this can cause a deformation of the acrylic
tank and a malfunctioning of the thermometer.
4. Connect the power cord of the glass heater to mains
voltage (AC 230V/50-60Hz). Turning the adjustment
knob in plus-direction increases the temperature, the
temperature is reduced by turning into the minus
direction
5. To adjust the temperature please turn the knob to
maximum (+).
Control temperature rise while heating up. When Temperature of 45°C is
reached, turn adjustment knob slowly in direction (-) until the indicator lamp
ist deactivated and the glass heater is OFF.
Markierung
gie - tec
ATTENTION!
Pay attention to the temperature of
etching bath. Temperaure higher than
+50°C may result in deformation of
the acrylic tank and may damage the
glass heater.
ATTENTION
2. Etching procedure
1. Switch-on the membrane pump by connecting the feeder to mains voltage.
2. Plug in the power cord f the heater to mains voltage. When bath
Carry corresponding protective
clothing (acid and alkal-proof
protection gloves, protective goggles,
overall or apron) when applying the
bath or when working with the device.
temperature of 45°C is reached you can start etching.
3. Clamp the board in the board holder and make sure, that the board is fixed
well.
At skin contact, rinse immediately
with lukewarm water and soap.
4. Immerse the board holder with the board into the tank.
5. After 5 to 10 minutes, the copper is removed.
6 Rinse the printed circuit board in water and dry the board
ATTENTION
Please notice:
The bath is saturated if the color of the liquid changes to a deep blue and
the etching times extend to more than 30 minutes. It has to be renewed.
The etching device is designed for
using sodium persulfat.
Don`t fill in iron-III-chloride or other
chemicals!
The etching liquid can remain in the cuvette without losing it´s effect for a
few days. Liquid losses due to evaporation can be compensated using
water.
If you don´t want to use the etching
device of a longer time, please
discharge the tank. Fill the etching
fluid in a plastic canister and store
them out of range of children and
foods.
After this fill water (approx.: 1l) in the
tank and switch on the membrane
pump for a few minutes to clean the
air curtain tube.
Technische Änderungen vorbehalten
Gie-Tec GmbH An der Schlierbach 18 D-36132 Eiterfeld Tel.: +49 (0)6672/919-910 E-Mail:info@gie-tec.de
l
l
l
l
www.gie-tec.de
gie - tec
ACHTUNG!
According the water law of Germany
(BGBI (186/1996) dated 19.04.1996),
the remainder content of copper is
limited to 0,5mg/l that may be
delivered to the drainage.
Because of new limits appointed by
the goverment, it is suitable to inquire
corresponding information of the
appropriate government agencies.
ATTENTION
Before cleaning the air curtain tube,
switch-off the glass heater.
3. Abwasserbeseitigung
Zum Ablassen der Ätzflüssigkeit (gesättigte Lösung oder bei längerer NichtNutzung des Ätzbades) stecken Sie den mitgelieferten PVC-Rohrstück in die
dafür vorgesehene Bohrung auf der dem Pumpengehäuse entgegengesetzten
Seite der Ätzküvette.
Verwenden Sie als Sammelbehälter ausschließlich verschließbare PVC-oder
Glasflaschen.
Bei der gesättigten Ätzlösung handelt es sich um Sonderabfall (Trichlorethan),
den Sie nach den örtlich geltenden Bestimmungen entsorgen müssen.
Ätzflüssigkeiten unbedingt außerhalb der Reichweite von Kindern
aufbewahren!
4. Maintenance and cleaning
lAccording to the application frequency, you should regularly clean the
etching device in order to guarantee a perfect working. This specially affects
the part pump, connecting tube, board holder etc.
Use only plastic container for storage
etching fluid.
Make sure that no etching fluid get
inside the safety valve. Running back
etching medium destroys the
maembrane pump.
Not required tools, equipment and
parts take away from working area.
Switch-off the device after use.
Cover the cuvette with the board
holder.
5. Spare parts
Glass heater for etching
device 1, (100W)
Art. Nr.: 411183
Glass heater for etching
device 2, (150W)
Art. Nr.: 411185
Glass thermometer (0 - 50°C)
Art. Nr.: 141900
Zur Erhöhung der Betriebsbereitschaft sollten Sie das Ätzgerät - je nach
Einsatzhäufigkeit - reinigen. Besonders pflegeintensive Bauteile sind der
Luftverteilerschlauch, die Luftschläuche, die Pumpe und den Platinenhalter.
Zur Grundreinigung entleeren Sie die Ätzküvette über das aufgesteckte
Ablaufrohr und füllen Sie ca. 0,5l Brauchwasser in die Küvette. Schalten Sie
nun die Pumpe ein.
Achten Sie darauf dass die Heizung nicht eingeschaltet ist!
Durch das Einblasen von Luft werden die Poren des hochporösen
Luftschlauches weitgehend gereinigt. Falls sich Poren durch Ätzkristalle
verstopft haben können Sie versuchen, vorsichtig mit einer kleinen Holz/PVCLeiste über den Luftschlauch zu streichen und damit die Kristalle zu entfernen.
Das Reinigen der Ätzküvette erfolgt ebenfalls über einer Holz- oder PVCLeiste die mit einem Schaumstoff (z. B. Tesa Moll) beklebt ist.
Bei Nichtgebrauch des Ätzgerätes ist es trotz Rückschlagventeil sinnvoll, den
Anschlussschlauch von dem/den Ventil(en) zu lösen. So ist eine
PCB holder for etching device 1
Art. Nr.: 149165 1000
PCB holder for etching device 2
Art. Nr.: 149167 1000
Membrane pump, etching device 1
Art. Nr.: 411155
Aerating frame, etching device 1
Art. Nr.: 149175 1000
Aerating frame, etching device 2
Art. Nr.: 149177 1000
www.gie-tec.de
Gie-Tec GmbH An der Schlierbach 18 D-36132 Eiterfeld Tel.: +49 (0)6672/919-910 E-Mail:info@gie-tec.de