Giant P217, P230, P221, P219, P218 User Manual 2

...
Series
Triplex Ceramic Plunger Pump Operating Instructions/ Repair and Service Manual
-18mm versions
For Models: P217 P218 P219 P220 P221 P227 P230
Updated 7/07
Contents:
Installation Instructions: page 2 Pump Specifications: pages 3-9 Exploded View: page 10 Parts List: page 11 Kits & Torque Specifications:page 12 Pump Mounting Selection Guide: page 12 Trouble Shooting: page 13 Recommended Spare Parts List: page 13 Repair Instructions: pages 14-15 Dimensions: back page Warranty Information: back page
INSTALLATION INSTRUCTIONS
Installation of the Giant Industries, Inc., pump is not a complicated procedure, but there are some basic steps common to all pumps. The following information is to be considered as a general outline for installa­tion. If you have unique requirements, please contact Giant Industries, Inc. or your local distributor for assistance.
1. The pump should be installed flat on a base to a maximum of a 15 degree angle of inclination to ensure optimum lubrication.
2. The inlet to the pump should be sized for the flow rate of the pump with no unnecessary restrictions that can cause cavitation. Teflon tape should be used to seal all joints. If pumps are to be operated at temperatures in excess of
0
160
F, it is important to insure a positive head
to the pump to prevent cavitation.
3. The discharge plumbing from the pump should be properly sized to the flow rate to prevent line pressure loss to the work area. It is essential to provide a safety bypass valve between the pump and the work area to protect the pump from pressure spikes in the event of a blockage or the use of a shut-off gun.
4. Use of a dampener is necessary to minimize pulsation at drive elements, plumbing, connec­tions, and other system areas. The use of a dampener with Giant Industries, Inc. pumps is optional, although recommended by Giant Industries, Inc. to further reduce system pulsa­tion. Dampeners can also reduce the severity of pressure spikes that occur in systems using a shut-off gun. A dampener must be positioned downstream from the unloader.
5. Crankshaft rotation on Giant Industries, Inc. pumps should be made in the direction desig­nated by the arrows on the pump crankcase. Reverse rotation may be safely achieved by following a few guidelines available upon request from Giant Industries, Inc. Required horsepower for system operation can be ob­tained from the charts on pages 3-9.
6. Before beginning operation of your pumping system, remember: Check that the crankcase and seal areas have been properly lubricated per recommended schedules. Do not run the pump dry for extended periods of time. Cavitation will result in severe damage. Always remember to check that all plumbing valves are open and that pumped media can flow freely to the inlet of the pump.
Finally, remember that high pressure operation in a pump system has many advantages. But, if it is used carelessly and without regard to its potential hazard, it can cause serious injury.
IMPORTANT OPERATING CONDITIONS
Failure to comply with any of these conditions invalidates the warranty.
1. Prior to initial operation, add oil to the crankcase so that oil level is between the two lines on the oil dipstick. DO NOT OVERFILL.
2. Pump operation must not exceed rated pressure, volume, or RPM.
A pressure relief device must be installed in the discharge of the system.
Use Giant 20W-50 oil (p/n 01153)
3. Acids, alkalines, or abrasive fluids cannot be
Crankcase oil should be changed after the
first 50 hours of operation, then at regular
pumped unless approval in writing is obtained before operation from Giant Industries, Inc.
intervals of 500 hours or less depending on operating conditions.
4. Run the pump dry approximately 10 seconds to drain the water before exposure to freezing temperatures.
2
Specifications
Model P217A
1750 RPM
+
Flow (Continuous) @ 2000 PSI (140 Bar) ...... 1.8 GPM ...................... 6.8 LPM
U.S. .............................. Metric
Flow (Intermittent) @ 2500 PSI (175 Bar) ...... 1.8 GPM ...................... 6.8 LPM
3450 RPM
+
Flow (Continuous) @ 2000 PSI (140 Bar) ...... 3.3 GPM ...................... 12.5 LPM
Flow (Intermittent) @ 2500 PSI (175 Bar) ...... 3.3 GPM ...................... 12.5 LPM
Maximum Inlet Pressure .................................... 145 PSI ........................ 10 b ar
Plunger Diameter ...............................................0.71”............................ 18 mm
Stroke .................................................................. 0.22”............................ 5.5 mm
Max. Temperature of Pumped Fluids ...............160
o
F........................... 71oC
Inlet Ports ................................................................................................... (2) 1/2" BSP
Discharge Ports ......................................................................................... (2) 3/8" BSP
Shaft Rotation ....................................................... Top of Pulley Towards Fluid End
Crankshaft Diameter .......................................... 0.98”............................ 24 mm
Key Width ..........................................................0.31” ............................ 8 mm
Shaft Mounting ...................................................Right Side Facing Manifold
Weight................................................................. 11.7 lbs. ....................... 5.3 Kg
Crankcase Oil Capacity ..................................... 7.5 fl.oz. ...................... 0.22 Liter
Extended Crankcase Oil Capacity ....................9.0 fl.oz. ...................... (0.27 Liter
Volumetric Efficiency @ 1750 RPM ...................................................... 0.94
Volumetric Efficiency @ 3450 RPM ...................................................... 0.87
Mechanical Efficiency @ 3450 RPM ...................................................... 0.86
+
Positive inlet pressure required
Consult the factory for special requirements that must be met if the pump is to operate beyond one or more of the limits specified above.
NOTE:
In order to drive the pump from the side opposite the present shaft extension, simply remove the valve casing from the crankcase and rotate the pumps 180 degrees to the desired position. Be certain to rotate the seal case (item #20) as well, so that the weep holes are down at the six o'clock position. Exchange the oil fill and the oil drain plugs, also. Refer to the repair instructions as necessary for the proper assembly sequence.
HORSEPOWER RATINGS:
P217A HORSEPOWER REQUIREMENTS
RPM GPM 1000 PSI 1500 PSI 2000 PSI 2500 PSI*
250 0.3 0.2 0.3 0.4 0.4
500 0.5 0.4 0.5 0.7 0.9 1000 1.0 0.7 1.1 1.4 1.8 1450 1.5 1.0 1.5 2.1 2.6 1750 1.8 1.2 1.9 2.5 3.1 3000 2.9 2.0 3.0 4.0 5.0 3200 3.1 2.1 3.2 4.2 5.3 3450 3.3 2.3 3.4 4.6 5.7
The rating shown are the power
requirements for the engine power outputs must be approximately twice the pump power requirements shown above.
We recommend a 1.15 service factor
be specified when selecting an electric motor as the power source. To compute specific pump horse power requirements, use the
*Intermittent duty only
following formula:
pump. Gas
HP = (GPM X PSI) / 1450
3
Specifications
Model P218A
U.S. .............................. Metric
Flow.....................................................................3.4 GPM ...................... 12.9 LPM
Pressure (Continuous) ....................................... 2000 PSI ...................... 140 Bar
Pressure (Intermittent) ....................................... 2500 PSI ...................... 175 Bar
Maximum Crankshaft Speed ................................................................... 1750 RPM
Maximum Inlet Pressure .................................... 145 PSI ........................ 10 b ar
Plunger Diameter ...............................................0.71”............................ 18 mm
Stroke .................................................................. 0.39”............................ 10.0 mm
Max. Temperature of Pumped Fluids ...............160
Inlet Ports ................................................................................................... (2) 1/2" BSP
Discharge Ports .........................................................................................(2) 3/8" BSP
Shaft Rotation ....................................................... Top of Pulley Towards Fluid End
Crankshaft Diameter .......................................... 0.98”............................ 24 mm
Key Width ..........................................................0.31” ............................ 8 mm
Shaft Mounting ...................................................Right Side Facing Manifold
Weight................................................................. 11.7 lbs. ....................... 5.3 Kg
Crankcase Oil Capacity ..................................... 7.5 fl.oz. ...................... 0.22 Liter
Extended Crankcase Oil Capacity ....................9.0 fl.oz. ...................... (0.27 Liter
Volumetric Efficiency @ 1750 RPM ...................................................... 0.94
Volumetric Efficiency @ 3450 RPM ...................................................... 0.87
Mechanical Efficiency @ 3450 RPM...................................................... 0.86
o
F........................... 71oC
Consult the factory for special requirements that must be met if the pump is to operate beyond one or more of the limits specified above.
NOTE:
In order to drive the pump from the side opposite the present shaft extension, simply remove the valve casing from the crankcase and rotate the pumps 180 degrees to the desired position. Be certain to rotate the seal case (item #20) as well, so that the weep holes are down at the six o'clock position. Exchange the oil fill and the oil drain plugs, also. Refer to the repair instructions as necessary for the proper assembly sequence.
HORSEPOWER RATINGS:
P218A HORSEPOWER REQUIREMENTS
RPM GPM 1000 PSI 1500 PSI 2000 PSI 2500 PSI*
250 0.5 0.3 0.5 0.7 0.8
500 1.0 0.7 1.0 1.3 1.7 1000 1.9 1.3 2.0 2.7 3.4 1450 2.8 1.9 2.9 3.9 4.9 1750 3.4 2.3 3.5 4.7 5.9
*Intermittent duty only
The rating shown are the power
requirements for the engine power outputs must be approximately twice the pump power requirements shown above.
We recommend a 1.15 service factor
be specified when selecting an electric motor as the power source. To compute specific pump horse power requirements, use the following formula:
pump. Gas
HP = (GPM X PSI) / 1450
4
Specifications
Model P219A
U.S. .............................. Metric
Flow.....................................................................4.2 GPM ...................... 15.9 LPM
Pressure (Continuous) ....................................... 2000 PSI ...................... 140 Bar
Pressure (Intermittent) ....................................... 2500 PSI ...................... 175 Bar
Maximum Crankshaft Speed ................................................................... 1750 RPM
Maximum Inlet Pressure .................................... 145 PSI ........................ 10 b ar
Plunger Diameter ...............................................0.71”............................ 18 mm
Stroke .................................................................. 0.49”............................ 12.4 mm
Max. Temperature of Pumped Fluids ...............160
Inlet Ports ................................................................................................... (2) 1/2" BSP
Discharge Ports ......................................................................................... (2) 3/8" BSP
Shaft Rotation ....................................................... Top of Pulley Towards Fluid End
Crankshaft Diameter .......................................... 0.98”............................ 24 mm
Key Width ..........................................................0.31” ............................ 8 mm
Shaft Mounting ...................................................Right Side Facing Manifold
Weight................................................................. 11.7 lbs. ....................... 5.3 Kg
Crankcase Oil Capacity ..................................... 7.5 fl.oz. ...................... 0.22 Liter
Extended Crankcase Oil Capacity ....................9.0 fl.oz. ...................... (0.27 Liter
Volumetric Efficiency @ 1750 RPM ...................................................... 0.94
Volumetric Efficiency @ 3450 RPM ...................................................... 0.87
Mechanical Efficiency @ 3450 RPM ...................................................... 0.86
o
F........................... 71oC
Consult the factory for special requirements that must be met if the pump is to operate beyond one or more of the limits specified above.
NOTE:
In order to drive the pump from the side opposite the present shaft extension, simply remove the valve casing from the crankcase and rotate the pumps 180 degrees to the desired position. Be certain to rotate the seal case (item #20) as well, so that the weep holes are down at the six o'clock position. Exchange the oil fill and the oil drain plugs, also. Refer to the repair instructions as necessary for the proper assembly sequence.
HORSEPOWER RATINGS:
P219A HORSEPOWER REQUIREMENTS
RPM GPM 1000 PSI 1500 PSI 2000 PSI 2500 PSI*
250 0.6 0.4 0.6 0.8 1.0
500 1.2 0.8 1.2 1.7 2.1 1000 2.4 1.7 2.5 3.3 4.1 1450 3.5 2.4 3.6 4.8 6.0 1750 4.2 2.9 4.3 5.8 7.2
*Intermittent duty only
The rating shown are the power
requirements for the engine power outputs must be approximately twice the pump power requirements shown above.
We recommend a 1.15 service factor
be specified when selecting an electric motor as the power source. To compute specific pump horse power requirements, use the following formula:
pump. Gas
HP = (GPM X PSI) / 1450
5
Loading...
+ 11 hidden pages