Giant HR2527A, HR3025, HR3030 User Manual

Triplex Ceramic Plunger Pump Operating Instructions/ Repair and Service Manual
Models HR2527A/HR3025/ HR3030 Pumps
Consumer Pumps
MADE IN THE USA
Updated 5/02
HR2527A shown
Contents:
Installation Instructions: page 2 Pump Specifications: pages 3-5 Exploded View: page 6 Parts List: page 7 Kits/Torgue Specs: page 8 Touble Shooting page 9 Repair Instructions: page 10-11 Dimensions/Warranty: back page
INSTALLATION INSTRUCTIONS
Installation of the Giant Industries, Inc., pump is not a complicated procedure, but there are some basic steps common to all pumps. The following information is to be considered as a general outline for installa­tion. If you have unique requirements, please contact Giant Industries, Inc. or your local distributor for assistance.
1. The pump should be installed flat on a base to a maximum of a 15 degree angle of inclination to ensure optimum lubrication.
2. The inlet to the pump should be sized for the flow rate of the pump with no unnecessary restrictions that can cause cavitation. Teflon tape should be used to seal all joints. If pumps are to be operated at temperatures in excess of
0
80
F, it is important to insure a positive head to
the pump to prevent cavitation.
3. The discharge plumbing from the pump should be properly sized to the flow rate to prevent line pressure loss to the work area. It is essential to provide a safety bypass valve
between the pump and the work area to protect the pump from pressure spikes in the event of a blockage or the use of a shut-off gun.
4. Reverse rotation may be safely achieved by following a few guidelines available upon request from Giant Industries, Inc. Required horsepower for system operation can be obtained from the charts on pages 3 and 6.
5. Before beginning operation of your pumping system, remember: Check that the crankcase and seal areas have been properly lubricated per recommended schedules. Do not run the pump dry for extended periods of time. Cavitation will result in severe damage. Always remember to check that all plumbing valves are open and that pumped media can flow freely to the inlet of the pump.
NOTE: An anti-sieze material must be applied to the engine cranckshaft to ensure trouble free disassembly of the pump.
Finally, remember that high pressure operation in a pump system has many advantages. But, if it is used carelessly and without regard to its potential hazard, it can cause serious injury.
IMPORTANT OPERATING CONDITIONS
Failure to comply with any of these conditions invalidates the warranty.
1. Crankcase oil should be changed after the first 50 hours of operation. Then at regular intervals of 500 hours or less depending on operating conditions.
Use Giant synthetic oil
2. Pump operation must not exceed rated pressure, volume, or RPM. device must be installed in the discharge of the system.
A pressure relief
3. Acids, alkalines, or abrasive fluids cannot be pumped unless approval in writing is obtained before operation from Giant Industries, Inc.
4. Run the pump dry approximately 10 seconds to drain the water before exposure to freezing temperatures.
NOTE: Contact Giant Industries for Service School Information. Phone: (419)-531-4600
2
Specifications
Model HR2527A
Axial Pump
Volume HR2527A .................................................................................2.5 GPM
Maximum Discharge Pressure .............................................................2750 PSI
o
F
1
o
angle)
Maximum Inlet Pressure ...................................................................... Up to 90 PSIG
RPM .....................................................................................................3450
Plunger Diameter .................................................................................. 16mm
Stroke .................................................................................................... 5.3mm (7.1
Crankcase Oil Capacity ........................................................................4.5 fl. oz.
Temperature of Pumped Fluids .............................................................Up to 80
Inlet Port ...............................................................................................1 x 1/2" NPT
Discharge Ports .................................................................................... 3/8" NPT
Shaft Rotation .......................................................................................Clockwise
Weight...................................................................................................11.7 lbs. (12.7 lbs.)
Width .....................................................................................................6-9/16"
Height ................................................................................................... 7-25/32"
Swash Plate Bore .................................................................................3/4" x 3/16" Keyway
Valve Type ............................................................................................ Polyamide Plastic
1
A 25 PSIG minimum inlet pressure is required.
HR2527A ELE CTRIC HORSEPOW E R
REQUIREMENTS
RPM GPM 1000 PSI 1500 PSI 2000 PSI 2750 PSI 3450 2.5 1.7 2.6 3.4 4.7
HORSEPOWER RATINGS:
The rating shown are the power
requirements for the engine power outputs must be approximately twice the pump power requirements shown above.
pump. Gas
HR2527A GAS HORSEPOWER
REQUIREMENTS
RPM GPM 1000 PSI 1500 PSI 2000 PSI 2750 PSI 3450 2.5 2.3 3.4 4.5 6.3
We recommend a 1.15 service factor
be specified when selecting an electric motor as the power source. To compute specific pump horse­power requirements, use the Follow­ing formula:
Electric HP = (GPM X PSI) / 1460 Gas HP = (GPM X PSI) / 1100
3
Specifications
Model HR3025
Axial Pump
Volume HR3030.................................................................................... 3.0 GPM
Maximum Discharge Pressure .............................................................2500 PSI
Maximum Inlet Pressure ...................................................................... Up to 90 PSIG
RPM .....................................................................................................3450
Plunger Diameter .................................................................................. 16mm
o
o
F
angle)
Stroke .................................................................................................... 5.9mm (8.0
Crankcase Oil Capacity ........................................................................4.5 fl. oz.
Temperature of Pumped Fluids .............................................................Up to 80
Inlet Port ...............................................................................................1 x 1/2" NPT
Discharge Ports .................................................................................... 3/8" NPT
Shaft Rotation .......................................................................................Clockwise
Weight...................................................................................................11.4 lbs.
Width .....................................................................................................6-7/16"
1
Height ...................................................................................................10-1/4"
Swash Plate Bore .................................................................................3/4 x 3/16 Keyway
Valve Type ............................................................................................ Polyamide Plastic
1
A 25 PSIG minimum inlet pressure is required.
HR3025 ELECTRIC HORSEPOWER
REQUIREMENTS
RPM GPM 1000 PSI 1500 PSI 2000 PSI 2500 PSI 3450 3.0 2.1 3.1 4.1 5.1
HORSEPOWER RATINGS:
The rating shown are the power
requirements for the engine power outputs must be approximately twice the pump power requirements shown above.
pump. Gas
HR3025 GAS HORSEPOWER
REQUIREMENTS
RPM GPM 1000 PSI 1500 PSI 2000 PSI 2500 PSI 3450 3.0 2.7 4.1 5.5 6.8
We recommend a 1.15 service factor
be specified when selecting an electric motor as the power source. To compute specific pump horse­power requirements, use the Follow­ing formula:
Electric HP = (GPM X PSI) / 1460 Gas HP = (GPM X PSI) / 1100