Giant GXR User Manual

Model
Triplex Plunger Pump Operating Instructions/ Repair Instructions Manual
GXR Series
Consumer Pump
Horizontal/Vertical Pump with built-in Regulator, Thermal Relief Valve and Siphon Injector
MADE IN THE USA
Updated 8/01
Contents:
Installation Instructions: page 2 Pump Specifications: page 3 Exploded View/Kits: page 4 Parts List: page 5 Torque Specifications: page 5 Repair Instructions: pages 6-7 Dimensions: back page Warranty Information: back page
INSTALLATION INSTRUCTIONS
Installation of the Giant Industries, Inc., pump is not a complicated procedure, but there are some basic steps common to all pumps. The following information is to be considered as a general outline for instal­lation. If you have unique requirements, please contact Giant Industries, Inc. or your local distributor for assistance.
1. For horizontal applications the pump should be installed flat on a base to a maximum of a 15 degree angle of inclination to ensure optimum lubrication.
4. Use of a dampener is necessary to minimize pulsation at drive elements, plumbing, connections, and other system areas. The use of a dampener with Giant Industries, Inc. pumps is optional, although recommended by Giant Industries, Inc. to further
2. The inlet to the pump should be sized for the flow rate of the pump with no unnecessary restrictions that can cause cavitation. Teflon tape should be used to seal all joints. Maximum inlet
o
fluid temperature is 80
F.
reduce system pulsation. Dampeners can also reduce the severity of pressure spikes that occur in systems using a shut-off gun. A dampener must be positioned downstream from the regulator.
6. Before beginning operation of your pumping
3. The discharge plumbing from the pump should be properly sized to the flow rate to prevent line pressure loss to the work area. It is essential to provide a safety bypass valve between the pump and the work area to protect the pump from pressure spikes in the event of a blockage or the use of a shut-off gun.
system, remember: Check that the crankcase and seal areas have been properly lubricated per recommended schedules. Do not run the pump dry for extended periods of time. Cavitation will result in severe damage. Always remember to check that all plumb­ing valves are open and that pumped media can flow freely to the inlet of the pump.
Finally, remember that high pressure operation in a pump system has many advantages. But, if it is used carelessly and without regard to its potential hazard, it can cause serious injury.
IMPORTANT OPERATING CONDITIONS
Failure to comply with any of these conditions invalidates the warranty.
1. Prior to initial operation, Check for proper oil level. DO NOT OVERFILL.
2. Pump operation must not exceed rated pressure, volume, or RPM.
A pressure relief
device must be installed in the discharge of the
Use Giant Synthetic Oil
Crankcase oil should be changed after the first 50 hours of operation, then at regular intervals of 500 hours or less depending on
system.
3. Acids, alkalines, or abrasive fluids cannot be pumped unless approval in writing is obtained before operation from Giant Industries, Inc.
operating conditions.
4. Run the pump dry approximately 10 seconds to drain the water before exposure to freezing temperatures.
NOTE: Contact Giant Industries for Service School Information. Phone: (419)-531-4600
Specifications
Model GXR Series
GXR2224..............................................................................................2.2 GPM @ 2400 PSI
GXR2424..............................................................................................2.4 GPM @ 2400 PSI
Maximum Inlet Pressure.......................................................................Up to 90 PSIG
RPM......................................................................................................3450
Plunger Diameter..................................................................................16mm
Stroke GXR2224 ..................................................................................4.7mm (6.1
Stroke GXR2424 ..................................................................................5.1mm (6.3
Crankcase Oil Capacity ........................................................................4.7 fl. oz. (4.1 fl.oz. horizontal)
Temperature of Pumped Fluids ............................................................Up to 80
Inlet Port ...............................................................................................1/2" NPT
Discharge Ports.....................................................................................3/8" NPT
Shaft Rotation.......................................................................................Either Direction
Weight...................................................................................................9 lbs.
Width ....................................................................................................8.325"
Height ...................................................................................................6.45"
Swash Plate Bore (Horizontal) .............................................................3/4" x 3/16" Keyway
Swash Plate Bore (Vertical) ..................................................................7/8" x 3/16" Keyway
Valve Type ............................................................................................Polyamide Plastic
1
A 25 PSIG minimum inlet pressure is required.
2
The pump itself can be driven in either direction of rotation; however, the cooling fan on TEFC motors must always be positioned so that the cooling air is drawn from the non-drive end of the motor towards the pump.
o
F
1
o
angle)
o
angle)
2
GXR2224 ELECTRIC HOR SEPOW E R
REQUI R EMENTS
RPM GPM 1000 PS I 1500 PSI 2000 PSI 2500 PSI 3450 2.2 1.5 2.3 3.0 3.8
GXR2224 GAS ENGINE HORSEPOWER
REQUIREMENTS*
RP M GPM 1000 P SI 1500 PS I 2000 PSI 2500 PSI 3450 2.2 2.0 3.0 4.0 5.0
GXR2424 ELECTRIC HORSEPOWER
REQUIREMENTS
RPM GPM 1000PSI 1500PSI 2000PSI 2400 PSI 3450 2.4 1.6 2.5 3.3 3 .9
GXR2424 GAS ENGINE HORSEPOWER
REQUIREMENTS*
RPM GPM 1000PSI 1500PSI 2000PSI 2400 PSI 3450 2.4 2.2 3.3 4.4 5.2
HORSEPOWER RATINGS:
The rating shown are the power
requirements for the
pump. Gas engine power outputs must be approximately twice the pump power requirements shown above.
We recommend a 1.15 service factor
be specified when selecting an electric motor as the power source. To compute specific pump horse­power requirements, use the Follow­ing formula:
Electric HP = (GPM X PSI) / 1460
Gas HP = (GPM X PSI) / 1100
* Engine power varies based on horizontal or
vertical orientation as well as by makes and model from each manufacturer.