Before You Begin ..............................................................................................................1.
What Is Included .....................................................................................................................................
Claims ................................................................................................................................................
Symbols .................................................................................................................................................
Safety Notes ...........................................................................................................................................
Introduction .......................................................................................................................
2.
Product Description..............................................................................................................................
Product Features .................................................................................................................................
Additional Products ..............................................................................................................................
Product Overview ....................................................................................................................................
Product Dimensions ................................................................................................................................
Setup And Installation ........................................................................................................
3.
AC Power ................................................................................................................................................
Fuse Replacement ..................................................................................................................................
Fuse Replacement Diagram ................................................................................................................
Mounting ..................................................................................................................................................
Signal Connection ...................................................................................................................................
Signal Connection Diagram .................................................................................................................
Installation Guidelines .............................................................................................................................
Configuration And Operation ............................................................................................
4.
Control Panel ...........................................................................................................................................
Menu Map ................................................................................................................................................
Using The Menu ......................................................................................................................................
Configuring Net Address ......................................................................................................................
Configuring Subnet Address ................................................................................................................
Configuring Universes .........................................................................................................................
Configuring DMX Outputs ....................................................................................................................
Configuring IP Addresses ....................................................................................................................
Configuration Examples ..........................................................................................................................
DMX Source (DMX Splitter) .................................................................................................................
Art-Net Source (Art -Net adapter) ..................................................................................................
Art-Net And DMX Sources ...............................................................................................................
Indicators .................................................................................................................................................
Technical Information ........................................................................................................
5.
Maintenance ............................................................................................................................................
Technical Specifications ....................................................................................................
6.
Dimensions And Weight ..........................................................................................................................
Power.......................................................................................................................................................
Data Connections ....................................................................................................................................
1
1 1
1
1 2
3 3
3
3
3
4
5 5 5
6 6 6
6
7 8 8
8 8 9 9 9 10 10 11 12
12
13
14 14 14
5
7
13
14
Before You Begin
Before You Begin 1.
What Is Included
Artnet DMX controller
IEC power cord
Warranty card
User Manual
Unpacking
Carefully unpack the condition.
Claims
Upon receipt, if the container or the contents (the product and included accessories) appear damaged from shipping, or show signs of mishandling, notify the carrier immediately,
Failure to do so in a timely manner may invalidate your claim with the carrier. In
For other issues such as missing components or parts, damage not related to shipping, or concealed damage, file a claim with us within 7 days of receiving the merchandise . For information on contacting us , see Contact Us
Symbols
fixtrue
the container and all the packing material for inspection.
Symbols Meaning
Critical installation, configuration, or operation information. Failure to comply with this information may cause the product not to work, damage third-party equipment, or cause harm to the operator .
Important installation or configuration information. Failure to comply with this information may keep the product from working.
Useful information.
and check that all the parts are in the package, and are in good
at the end of this Manual.
addition, keep
Page 1 of 14
Safety Notes
Please read the following Safety Notes carefully before starting to work with the product. These notes provide important safety information about the installation, usage, and maintenance.
.
Always connect this product to a grounded circuit.
.
Make sure the power cord is not crimped or damaged. Always connect this product to a power source with the proper voltage as listed on the product sticker.
.
Do not operate the product if there is damage to the housing. This product is for indoor use only! It is rated IP20. Do not expose the product to rain or moisture.
.
Always disconnect this product from power before cleaning it or changing the fuse.
.
Never disconnect the product from the power source by pulling or tugging on the cord.
.
If mounting the product overhead, always secure it using a safety cable.
.
Make sure there are no flammable materials close to the product when it is operating.
Before You Begin
.
This product is not intended for permanent installation.
.
Never connect the product to a dimmer or a rheostat.
.
Always install the product in a location with adequate ventilation.
.
Do not operate the product in an ambient temperature higher than
o
104 F (40 C).
.
This product contains no user-serviceable parts. Any reference to servicing in this User Manual will only apply to properly trained us certified technicians. Do not open the housing or attempt any repairs.
.
Any damages caused by manual modifications are not subject to warranty. Our will not accept liability for damage caused by unauthorized modifications or not observing the safety warnings and instructions in the manual.
.
All applicable local codes and regulations apply for proper installation of this product.
.
In the event of a serious operating problem, stop using the product immediately.
.
If the product requires repair contact us For more information see Returns and Contact Us.
Keep this User Manual for future reference.
o
Page 2 of 14
Introduction
Introduction 2.
Product Description
The fixture is a reliable and versatile rack integrated optical DMX splitter and Art-Net hub capability . It has two 3-pin DMX In ports and eight 3-pin DMX O ut ports, all optically isolated. It takes up to 8 simultaneously. The eight 3-pin DMX O ut ports can be assigned to either of the DMX I n ports or to one of the Art-Net Neutrik ether CON ports . Neutrik ether CON ports are through ports that allow daisy chaining of the fixture units.
The fixture provides a reliable, highly customizable network infrastructure for complex control systems.
Product Features
.
Rack mountable
.
Both an Art-Net node and an optical splitter
.
Eight optically isolated output ports
.
Variable operating modes for all DMX outputs
.
Two Neutrik etherCON in/through ports
mountable
-
Art-Net
-
DMX adapter with an
-
to
Net
-
Art
universes
Additional Products
The fixture is an adapter and hub combined that works as part of a control system. Our has a line of video products and lighting products that work with the
Product Overview
fixture.
Page 3 of 14
Product Dimensions
1.7 in
44.4 mm
6.6 in
167.9 mm
Introduction
LINK
DMX1
DMX2
DATA
17.4 in
443 mm
Menu
0.9 in
23.5 mm
4.7 in
120 mm
19 in
483 mm
15.3 in
390 mm
Page 4 of 14
Setup And Installation
Setup And Installation 3.
AC Power
The fixture 100~240 VAC, 50/60 Hz. To determine the power requirements for refer to t label affixed to the product or Technical Specifications
The listed rating indicates the maximum current draw during normal operation.
Always connect this product to a properly grounded and protected circuit. Never connect this product to a rheostat (variable resistor) or dimmer circuit, even if the rheostat or dimmer channel serves only as a 0 to 100% switch.
Fuse Replacement
1. Disconnect the product from power.
2. Wedge the tip of a flat-head screwdriver into the slot of the fuse holder.
3. Pry the fuse holder out of the housing.
4. Remove the blown fuse from the holder.
5. Replace with a fuse of the exact same type and rating.
6. Insert the fuse holder back in place and reconnect power.
has a n internal auto-ranging power supply that works with an input voltage range of
the fixture
.
he
Disconnect the product from power before replacing the fuse.
Fuse Replacement Diagram
Spare Fuse Holder
(inside safety cap)
Always replace a blown fuse with another of the same type and rating.
A spare fuse is not included; however, the safety cap has room for a spare.
Installed Fuse
(held by plastic clip)
Safety Cap
Mounting
The fixture placed where the menu and the ports are accessible, and where there is adequate ventilation.
fits nicely in a standard 19" rack, or sits on a flat surface. should be
Signal Connection
The fixture
It sends signal out through 8 DMX Out ports and the other Neutrik etherCON port.
Signal Connection Diagram
receives signal though 2 DMX I n ports and one of 2 Neutrik etherCON port
To Another
Or Other Art-Net Products
1 1
Setup And Installation
The fixture
5
4
2
3
1
3
2 2
6
6
4
5
7
8
8
7
The fixture
From Art-Net Sources
ART-NET/KLIN G-NET
2
2
1
s.
.
The Neutrik etherCON ports are through ports. Each port can be either an input or an output port.
.
The DMX ports can only be input or output ports. There are 2 DMX In ports and 8 DMX Out ports.
Installation Guidelines
The fixture
products. The physical and digital construction of the control network is determined by the location and signal needs of the products.
When designing a control system that uses the
.
Placing the so the menu and ports can be accessed
.
Running the cables so there is no tension or pull on the cables or plugs
.
Planning a large control system carefully before configuring the components, so IP address, DMX address, and other identifiers are not duplicated
is used as part of a control system for operating various lighting and multi-media
fixture
fixture
From DMX Sources
To DMX
Controlled
Products
,
consider the following:
Page 6 of 14
Configuration And Operation
Configuration And Operation 4.
assigned to the DMX Out ports, but the Net , Subnet, and IP address settings do not need configuration.
be assigned to the DMX Out ports, and the Net, Subnet, and IP address settings must be configured.
which case both the DMX assignments and the Art-Net settings must be configured. For more information, see Configuration Examples
DMX In ports and Art-Net universes can be assigned to multiple DMX Out ports.
Control Panel
The control panel is the mechanism for configuring settings. It has a small LCD screen and five buttons, which are described below.
is configured through the control panel, using the control panel buttons. Once
is properly configured it operates without user intervention.
can be used as a DMX splitter only, in which case the DMX In ports must be
can be used as an Art-Net? hub, in which case the Art-Net universes must
can be used as both a DMX splitter and an Art-Net hub simultaneously, in
.
Menu Map
The menu map shows the organization of the configuration settings. Use it for reference when configuring the .
Main Function Programming Levels Description
<Universe #1> to
<Universe #8>
<DMX Output #1> to
<DMX Output #8>
<IP Address #1>
<IP Address #2>
<Device ID>
fixture
<Net> 0~127
<Subnet> 0~127
0~15
ArtNet Input
DMX #1 Input
DMX #2 Input
Without Input
x.xxx.xxx.xxx
xxxxxxxxx
Configuration And Operation
Sets the Net address
Sets the Subnet address
Sets the Art-Net universe for the corresponding DMX Out port (only necessary if the DMX port is set to Art-
Input source for each DMX Out port is Art-Net
Input source for each DMX Out port is DMX In port 1
Input source for each DMX Out port is DMX In port 2
DMX Out port is turned off
Sets the two IP addresses for the fixture Note: The addresses cannot be the same.
Shows the fixture device ID
Net)
Using the menu
The menu is used by pressing the 4 control buttons as described in the next sections.
Configuring Net
Address
The Net is the address of the network on which the fixture- is operating. The Net address must be configured if the fixture is being used as an Art-Net hub .
To configure the Net setting, do the following:
1. Press <MENU> repeatedly until <Net> shows in the display.
2. Press . The number in the lower right-hand corner of the display flashes.
<RIGHT>
3. Press <UP> or <DOWN> until the desired Net shows.
4. Press .
<RIGHT>
Configuring Subnet Address
The Subnet is the address of the subnet of the network on which the fixture is operating. The Subnet address must be configured if the fixture is being used as an Art-Net hub.
To configure the Subnet setting, do the following:
1. Press <MENU> repeatedly until <Subnet> shows in the display.
2. Press <RIGHT>
3. Press <UP> or <DOWN> until the desired Subnet shows.
4. Press .
<RIGHT>
. The number in the lower right-hand corner of the display flashes.
Page 8 of 14
Configuration And Operation
Configuring Universes
Universes are assigned to DMX O ut ports when the fixture is used as an Art -Net -to-DMX adapter. The universes are part of the process by which the fixture takes the Art -Net protocol and converts it to DMX. There are 16 Art-Net universes (0-15) that can be assigned to the DMX Out ports. Any one universe can be assigned to more than one DMX Out port.
The menu structure presents each DMX Out port as <Universe #X>, where X is the DMX Out port. The Art-Net? universes are assigned by selecting a value from 0 to 16.
To assign an Art-Net? universe to a DMX Out port, do the following:
1. Select the DMX O ut port to assign an Art-Net? universe to by pressing <MENU> repeatedly until <Universe #X> shows in the display.
2. Press <RIGHT>
3. Press <UP> or <DOWN> until the desired Art-Net universe shows.
4. Press .
<RIGHT>
Configuring DMX Outputs
The DMX Out ports must be configured to accept signal from either one of the DMX I n ports, or from the Art-Net source. If the DMX port is not being used it should be turned off.
. The number in the lower right-hand corner of the display flashes.
The menu structure presents each DMX Out port as a <DMX Output #X>, where X is the DMX Out port.
To configure the DMX Out ports, do the following:
1. Select the DMX Out port to configure by pressing <MENU> repeatedly until <DMX Output #X> shows in the display.
2. Press . The phrase in the lower right-hand corner of the display flashes.
3. Press <UP> or <DOWN> until the desired DMX input source or state of the port shows.
4. Press .
<RIGHT>
<RIGHT>
Configuring IP Addresses
The IP address is the address of the fixtrue on the network. It must be configured if the fixtrue is being used as an Art-Net hub.
To configure the IP Address, do the following:
1. Press <MENU> repeatedly until <IP Address #1> shows in the display.
2. Press . The left-most set of 3 digits on the display flashes.
3. Press <UP> or <DOWN> to change that set of numbers.
4. Press .The next set of 3 digits on the display flashes.
5. Press <UP> or <DOWN> to change that set of numbers.
6. Press .The right-most set of 3 digits on the display flashes.
7. Press <UP> or <DOWN> to change that set of numbers.
8. Press <MENU>.
<RIGHT>
<RIGHT>
<RIGHT>
Page 9 of 14
Configuration Examples
The fixture is extremely versatile
capabilities which can be combined so that the fixture is acting as a Art-Net adapter, and an Art-Net hub.
DMX Source (DMX Splitter)
DMX source-only configuration uses the fixture as a DMX splitter. The DMX signal comes in from one or both of the DMX In ports and goes out through one or more of the DMX Out ports.
To configure the fixture as a DMX splitter with the input and output assignments listed here
.
DMX In port 1 goes to DMX Out ports 4 and 5
.
DMX In port 2 goes to DMX Out ports 7 and 8
Do the following:
1. Disable unused DMX Out ports by doing the following for DMX Out ports 1, 2, 3, and 6:
a) Press <MENU> repeatedly until <DMX Output Port #X> shows on the display. b) Press <RIGHT> c) Press <UP> or <DOWN> until <Without Input> shows in the lower right-hand
corner.
d) Press . <Without Input> stops flashing.
2. Configure the DMX Out ports that will receive from DMX In port 1 by doing the following for DMX Out ports 4 and 5:
a) Press <MENU> repeatedly until <DMX Output Port #X> shows on the display. b) Press . The phrase in the lower right-hand corner of the display flashes. c) Press <UP> or <DOWN> until <DMX #1 Input> shows in the lower right-hand corner. d) Press . <DMX #1 Input> stops flashing.
3. Configure the DMX O ut ports that will receive from DMX In port 2 by doing the following for DMX Out ports 7 and 8:
a) Press <MENU> repeatedly until <DMX Output Port #X> shows on the display. b) Press . The phrase in the lower right-hand corner of the display flashes. c) Press <UP> or <DOWN> until <DMX #2 Input> shows in the lower right-hand corner. d) Press . <DMX #2 Input> stops flashing.
<RIGHT>
<RIGHT>
<RIGHT>
<RIGHT>
<RIGHT>
<RIGHT>
. The phrase in the lower right-hand corner of the display flashes.
with
DMX source
Configuration And Operation
capabilities
and Art-Net
DMX
source
splitter, an
Page 10 of 14
Configuration And Operation
Art-Net Source (Art-Net adapter)
Art-Net source-only configuration uses the fixture as an Art-Net to DMX adapter. The
Net
signal comes in from the through one or more of the DMX Out ports.
To configure the fixture as an Art-Net to DMX adapter with the addresses and DMX Out port assignments listed here:
.
Net setting of 3
.
Subnet setting of 7
.
IP addresses of 10.255.255.009 and 10.255.255.011
.
Art-Net universe 4 going to DMX Out port 1
.
Art-Net universe 8 going to DMX Out port 2
Do the following:
1. Set the Net address to 3 by doing the following:
a) Press <MENU> repeatedly until <Net> shows in the display. b) Press . The number in the lower right-hand corner of the display flashes. c) Press <UP> or <DOWN> until 3 shows. d) Press .
2. Set the Subnet address to 7 by doing the following:
a) Press <MENU> repeatedly until <Subnet> shows in the display. b) Press . The number in the lower right-hand corner of the display flashes. c) Press <UP> or <DOWN> until 7 shows. d) Press .
3. Set the IP addresses by doing the following:
a) Press <MENU> repeatedly until <IP Address #1> shows in the display. b) Press . The left-most set of 3 digits on the display flashes. c) Press <UP> or <DOWN> until those numbers show 255. d) Press .The next set of 3 digits on the display flashes. e) Press <UP> or <DOWN> until those numbers show 255. f) Press .The right-most set of 3 digits on the display flashes. g) Press <UP> or <DOWN> until those numbers show 009. h) Press i) Press <MENU> repeatedly until <IP Address #2> shows in the display. j) Press . The left-most set of 3 digits on the display flashes. k) Press <UP> or <DOWN> until those numbers show 255. l) Press .The next set of 3 digits on the display flashes. m) Press <UP> or <DOWN> until those numbers show 255. n) Press .The right-most set of 3 digits on the display flashes. o) Press <UP> or <DOWN> until those numbers show 011. p) Press <MENU>.
4. Disable the unused DMX Out ports by doing the following for DMX Out ports 3 to 8:
a) Press <MENU> repeatedly until <DMX Output Port #X> shows on the display. b) Press . The phrase in the lower right-hand corner of the display flashes. c) Press <UP> or <DOWN> until <Without Input> shows in the lower right-hand
d) Press . <Without Input> stops flashing.
<RIGHT>
<RIGHT>
<RIGHT>
<RIGHT>
<RIGHT>
<RIGHT>
<RIGHT>
<RIGHT>
<RIGHT>
<RIGHT>
<RIGHT>
<RIGHT>
corner.
<RIGHT>
Art
-
source to the Neutrik etherCON port and goes out
Page 11 of 14
5. Configure the DMX ports that will receive Art-Net? signals by doing the following for DMX Out ports 1 and 2:
a) Press <MENU> repeatedly until <DMX Output Port #X> shows on the display. b) Press . The phrase in the lower right-hand corner of the display flashes. c) Press <UP> or <DOWN> until <ArtNet Input> shows in the lower right-hand corner. d) Press . <ArtNet Input> stops flashing.
6. Configure Art-Net universe for the DMX ports that will receive Art-Net by doing the following:
a) <MENU> repeatedly until <Universe #1> shows in the display. b) Press . The number in the lower right-hand corner of the display flashes. c) Press <UP> or <DOWN> until 4 shows on the display. d) Press . 4 stops flashing. e) <MENU> repeatedly until <Universe #2> shows in the display. f) Press . The number in the lower right-hand corner of the display flashes. g) Press <UP> or <DOWN> until 8 shows on the display. h) Press . 8 stops flashing.
Art-Net And DMX Sources
Art-Net and DMX sources configuration uses the fixture as both a DMX splitter and Art-Net adapter. Configure this operating mode by combining the configurations for the DMX source and the Art ­Art-Net Source.
Net
source, which are described in detail in DMX Source
Configuration And Operation
and
Keep the following in mind when configuring the fixture for use as a combination optical DMX splitter and Art-Net adapter.
Disable any unused DMX Out ports. DMX Out ports can output only DMX or Art-Net , not both.
Indicators
The three LED indicator lights on the front of the fixture , next to the menu display, indicate when there is power, DMX, or Art-Net . The table below shows the behavior of the lights and what it means.
Indicator Behavior Meaning
Solid red Power is getting to the fixture
POWER
Off Power is not getting to the fixture
Blinks red Art-Net? signal is getting to the fixture
SIGNAL
Off Art-Net? signal is not getting to the fixture
Blinks red DMX signal is getting to the fixture
DMX
Off DMX signal is not getting to the fixture
Technical Information
Technical Information 5.
Maintenance
To maintain optimum performance and minimize wear, the user should clean this product regularly. Usage and environment are contributing factors in determining the cleaning frequency.
As a rule, clean this product at least twice a month. Dust build- up reduces light output performance and can cause overheating. This can lead to reduced light source life and increased mechanical wear.
To clean the fixture, do the following:
1. Unplug the panel from power.
2. Wait until the unit is at room temperature.
3. Use a vacuum (or dry compressed air) and a soft brush to remove dust collected on the external vents.
4. Clean all external surfaces with a mild solution of non-ammonia cleaner or isopropyl alcohol.
5. Apply the solution directly to a soft, lint-free cotton cloth or a lens cleaning tissue.
6. Make sure all connections are thoroughly dry before reconnecting power and signal cables.
.
Keep the environment around the fixture free of dust, dirt, water, and extreme temperatures.
.
Insert and remove DMX and Neutrik ether CON cables slowly and gently.
.
Put the fixture
.
Turn the fixture
on the top of any stacks of equipment, or rack mount it.
off when it is not in use.
Always dry the external surfaces carefully after cleaning them.
Page 13 of 14
Technical Specifications 6.
Dimensions And Weight
Length Width Height Weight
19 in (483 mm) 6.6 in (168 mm) 1.8 in (45 mm) 4.4 lb (2.0 kg)
Power
Power Supply Range Voltage Selection
Data Connections
Switching (internal) 100 to 240 VAC, 50/60 Hz Auto-ranging
Parameter 120 V, 60 Hz 208 V, 60 Hz 230 V, 50 Hz
Consumption 10 W 10 W 10 W
Operating Current 0.25 A 0.14 A 0.13 A
Power Connection Power Input
Edison Plug to IEC (US/Canada)
Local plug to IEC (Worldwide)
Data Throughputs Neutrik etherCON ( 2 total)
Technical Specifications
IEC
I/O Type
Data Inputs
Neutrik etherCON ( 2 total)
3-pin XLR (2 total)
Data Outputs 3-pin XLR (8 total)
Page 14 of 14