Gianni Industries PBA-860 User Manual

PBA-860 Micro Switch Bar
The PBA-860 Mechanical Micro Switch Bar is focus on emergency exit doors (or other large-scale type doors), with a pressure push immediately cut the interior micro switch unlocking the electromagnet lock or other similar devices. Easy to install attractive brushed aluminum bar with black base and trim. Available in dimension of 875(L)*60(W)*65(D)mm Standard Sized in Satin Silver, Red and Green Colors for versatile applications.
N.C.
PBA-860
micro switch output
Com.
N.O. N.C.
Com.
N.O.
Double pole
Electrical Specifications SPDT 5 Amp 125Vac
N.C.
Com.
N.O. N.C.
Com.
N.O.
Power Supply
EM Lock (fail-safe)
Voltage output to lock and dry SPDT auxiliary output.
Copyright Gianni Industries, Inc. All Rights Reserved.
PublishP-MU-PBA860 Ver. D :2007.03.23
Electrical Specifications SPDT 5 Amp 125Vac
N.C.
Com.
N.O. N.C.
Com.
N.O.
Com.
N.O.
Time delay relay
N.C.
Com.
Power Supply
N.O.
Time delay or access control request to exit
Dry contact output to TD or access control and dry SPDT auxiliary output.
EM Lock (fail-safe)
PBA-860TDI control panel wiring diagram
Switch 2 output
Red (N/C)
Black (COM.)
White (N/O)
35 1
Adjustable delay timer (1-30 SECONDS)
95db Sounder
J2
N.C. / N.O. trigger selectable
N.O. Rigger
N.C. Rigger
Key switch
(Switch 1 output)
J1 Set contact time for triggering
RESET contact
RESET contact
Power output 12 Vdc-
Power output 12 Vdc-
Power input 12 Vdc-
Power input 12 Vdc+
GEM
Electromagnetic lock
(Fail-safe)
Power supply
Buzzer signal output
signal input for emergency
OUT +/- (Over pass timer
setting prior to cut out power
J3
N.C. / N.O. trigger selectable
START
V-
out+
V+
N.C.
COM.
N.O.
CUT INPUT
CUT INPUT
out-
RESET
RESET
RELAY
for mergency condition
N.O.Rigger
N.C.Rigger
0.5 second (Power)
()Buzzer
3 seconds constant contacting
Manual Instructions * P1 , P2 setting for trigger N.O. or N.C. contact and timmer adjustable. * OUT +/- voltage output eliminated after1-30seconds delay timer set, an over pass timer setting OUT +/- prior to cut out power
instantly when emergency (CUT INPUT) condition. * P3 setting for trigger N.C. or N.O. contact on emergency condition. * Buzzer and signal output for termination control purposer, contact rated 3A@12VDC or 1A@125VAC * RESET for stand by activation. * Electromagnet lock is fail-safe version, recommend to use UL approved power supply unit for UPS (uninterruption Power Supply)
system integration at any time.
Copyright Gianni Industries, Inc. All Rights Reserved.
PublishP-MU-PBA860 Ver. D :2007.03.23