Gianni Industries L-NH500 User Manual

The A value in the table below for each bracket to mount on the door frame, shows the minimum requirement width of the door frame for different electromagnetic lock model.
Magnet Grade Option Brackets
300 LBS
600 LBS
800LBS
1200 LBS
ValueA"
38mm
42mm
48mm
60mm
L-150, L-EM150...
L-300,L-10001ST...
L-750, L-350,L-400... L-500,L-600...
L-NH500 Bracket
Typical mounting on OUT-SWINGINGnarrow frame door
Door
Magnet
Frame
A
Door Leaf
Out-swinging
"L" brackets
267
48
Application for the Electromagnet: EM-NH500 Series
1
Fold the mounting template along the dotted line to a 90-degree angle. Close the door, place the template against the door and frame.
4
2
Drill three holes in the door as indicated on the template.
5
Mounting Plate
EM-NH500
Hollow Metal Door
3
Drill an 8 mm hole through door, from sexnut bolt side only, enlarge the 8mm hole to 16mm.
6
267
75
Unit:mm
267
Reinforced Door
16mm8mm
6.8mm for M8-1.25 thread
Drill an 6.8 mm dia. Hole and tap for M8x12.5 thread.
8
40
71
40
Solid Door
Drill an 8 mm hole thru door from sexnut bolt side of door, drill
12.7mmhole, 36mm in depth.
36mm
12.7mm8mm
Finish
Power Power
Lock the armature plate and L bracket first. Put the electromagnet into the armature plate second.
Turn on the power of EM-Lock, and let the armature plate bonds to the EM-lock. Adjust the position between the L bracket and the door frame.
GIANNI INDUSTRIES, INC.
No. 13, Zhong Sing Road, Tu-Cheng Industrial Zone, Tu-Cheng City, Taipei, Taiwan 23678 Tel: 886-2 2267 7986 / Fax: 886-2 2267 9876
E-Mail: info@gianni.com.tw Website: gianni.tw
Copyright 2008 Gianni industries, inc. All rights reserved. DM-CA-L-NH500 Ver.A Published on 2008.06.16
Once the position is correct, use the screws to permanently mount the L bracket on the door frame.
The products are manufactured under an ISO 9001 QC 080000 Certified Quality Management Program environment back its product quality, performance and commitment to customersatisfaction.
Test the unit. Insert the antiĀ­tamper caps into the mounting screw access holes.
&
Loading...