Gianni Industries GEM EB260, GEM EB260M Specification

E B260 electr ic d ropbo lt i nc orpor at es a m ec hanic al c ylinder
to lo ck or u nlock t he do or manu ally in case of a n unexp ected power fai lure.
EB260/EB260M ELECTRIC DROPBOLT
Dimensions
Specification
45
5 mm maxi
Reed
The door close sens or can det ec t wi thin a ran ge of 5 m m. If t he d oo r ga p is too wid e, a mag ne t wi thin the strike pla te c an be adjust ed to impro ve dete ct ion acc ur acy.
Adju st able Sensor
GIANNI I NDUSTRIES, INC.
Do or l oc king time de lay lasts from 1.5 to 9 se conds adjusta ble by jump er PINs .
1.5 secon ds 3second s 6 seconds 9 second s
Relo ck Ti me Delay
Cop yrigh t © Giann i Indus tries , Inc. All r ights r eserv ed. DM- CA-EB -260 Ver. F P ublis hed on 20 11.0 6.22
Unit: mm
4
8
3
0
260
220
3
8
260
240
30
220
16
20
20
3
5
27
3
No. 13, Z hon gxing R d., Tu cheng D ist ., Ne w Taipe i City 23 6,Tai wan (R. O.C .)
Tel: 88 6-2 2 267 798 6 / Fax : 886-2 2 267 9 876
E-Mai l: in quiry @gi anni. com .tw Web site: g ian ni.tw
The product is w arrante d ag ainst d efect s in m ateri al a nd workman ship while used in norm al ser vice for a p er iod of 1 year fr om the da te of sal e to the or iginal cu stome r. The G EM policy is one of continu al d evelopm ent an d im proveme nt; therefo re GE M reserv es th e righ t t o chan ge sp ec ifica ti ons without n otice.
Warranty
Door L ea f Flush Installatio n
Opti on al Access or y
12 to 28 VD C self-regulating
The El ectric Dropb olt operates on 12 to 28 VDC input voltage w ith self re gulat in g featu re .
Th e specia lly de signed s oleno id aims f or str ength an d long life. The soleno id is gua ra nteed 5 00 ,000 ti me s of oper ations.
Long L if e Solenoids
Pull in
Holding
Current D raw (mA)
Tim e (second s)
EB260 can b e fitte d to t he side o f th e door.
Cylinde r is operat ed by thumb tur n indoors o r a key from ou tdoors.
DL -2 00
Door Loop
The Door Lo op is used to protect extensi on wirin g from damages wit h high secur ity concern s.
Ener gy S aving Design
After the dr opbol t is co mpletel y lock ed , the curr en t draw changes f rom 1.0 A to 0. 3A to prol on g its lif e.
GIANNI I NDUSTRIES, INC.
(Open)
(Auto-r elockin g time delay (0. 15~9 sec. )
(Close)
(Close)
EB260/EB260M ELECTRIC DROPBOLT
Cop yrigh t © Giann i Indus tries , Inc. All r ights r eserv ed. DM- CA-EB -260 Ver. F P ublis hed on 20 11.0 6.22
No. 13, Z hon gxing R d., Tu cheng D ist ., Ne w Taipe i City 23 6,Tai wan (R. O.C .)
Tel: 88 6-2 2 267 798 6 / Fax : 886-2 2 267 9 876
E-Mai l: in quiry @gi anni. com .tw Web site: g ian ni.tw