LZ -5 00N Bracket
Typical mounting on IN-SWINGING door
L-Bracket
Armature
Plate
Frame
Applicatio n for the Elec tromagnet:
10010, EM-12 00 , 10060(D ouble), EM-2200(Double) S eries
.5
3
6
6
3.
5
6
190
8
Z-Bracket
In-swing
8
3
2
1
90
3.5
6
3.5
6
Door
2
65
(
54
26
(
7
2
)
5
6
)
7
6
8
6
Unit:m m
Minimal:76mm
Installation of LZ bracket on In-swing Doors
21
Instal l L bra cket on the doo r f rame .
M ake s ure t he d oo r m ay b e
opened /cl osed.
5
Fa sten the arm atu re p late to Z
bracke t. I nsert the ru bbe r wa sher
betwee n the m.
Copyright © Gianni Industries, Inc. All rights reserved.
DM-CA-LZ-500N Ver. D Published on 2011.0 9.08
Fa st en th e e lectromag ne t t o L
bracke t wit h fixing sc rews.
6 7 Finish
Close th e door a nd turn on the
power.
3
Assemb le Z bracket . Make su re i t is
still lo ose .
4
Insert the guide pi ns in to th e
armatu re pl ate.
Power
L e t t he a r m a ture p l a te a n d
electr oma gnet bond toge the r. Pre ss
Z bracke t to th e door leaf .
Fasten Z b rac ket to the do or leaf.
GI AN NI INDUSTRIES, INC.
No. 13, Zh ong xing Rd., Tu cheng Dis t., New Taipe i
City 236 ,Taiw an (R.O.C .)
Te l: 886 -2 22 67 79 86 / Fax : 886 -2 226 7 987 6
E-Mail : inq uiry@gi anni.co m.tw
Web sit e: gianni .tw