Operating Features
EM-NH600M: Bond sensor output & Status LED
Bond sensor is used to indicate the door status as in a locked or unlocked condition. is a visual feedback for user to give the true status of
the lock at any time. Green light indicates the door is insecure (unlocked) and the Red light is indicates the door is secure (locked).
Bond sensor monitor output : SPDT rated: 3A@12VDC
Status LED
Patent: ZL 2006 2 0122522.X Nr. 20 2006 012 052.1 M308308 GB 061 6099.8 06 07229(France)
Features
MOV provides spike and surge protection. Automatic relocking time delay Magnetic bond sensor monitor output. Bi-color LED indicates lock/unlock status. Anodized aluminum housing. Groove template & housing for easy installation. Dual voltage 12 or 24 VDC selectable
().
Anti-Residual magnetism designed. Complete mounting hardware included.
Statement
EM-NH600
The electromagnet lock is an important mounting plate design breakthrough. The mounting plate is designed with a well engineered sliding mechanism that makes electromagnet considerably easy to clasp the mounting plate to allow security of use and maximize the ease of installation. Therefore, even if used for longer periods, the tricky innovation in its design will prevent the electromagnet of being falling when the screw are loosening up .
Specifications
Voltage Tolerance: ±15% Current Draw: 500mA@12Vdc 250mA@24Vdc
()
at 20 degree centigrade Operating Temperature from -10 to 55 degree centigrade Humidity: 0~95% non-condensing. Holding Force: Up to 600 lbs (272 Kg) Dimensions:
Magnet:(L) 250, (W) 46, (D) 25 mm Armature Plate:(L) 185, (W) 38, (D) 12 mm
Mounting Plate:(L) 250, (W) 25, (D) 5 mm Finishes for magnet and armature plate: Zinc Epoxy Potting Compound: E87252 (S), UL94V-0 Weight (Approx.): 2.0 Kg Magnetic bond sensor monitor output (SPDT rated
3A@12V DC), remotely monitors the door lock or
unlock status. Status LED: Lights GREEN when the door is unlocked, lights RED when the door is locked. Automatic relocking time delay: 1~90 seconds.
;
Trigger
TimerAdjust
Shorten
EM-NH600M-TD: Re-locking time delay
Relocking Time Delay Switch ensures the
N.C.
automatically turns to lock mode after the
COM.
door is closed properly and it can be
N.O.
adjusted from 0 to 90 seconds.
Power
Input
SPDT relay
3A@12VDC
Special Mounting Plate design
Cable
Fasten the mounting plate on the site then install electromagnet lock with power lead cable through mountingplate slot hole.
For assembling the mounting plate and the electromagnet lock into the groove, please make the mark on the mounting plate and the mark on the electromagnet lock itself to be a straight line for alignment. Either aligning from left side or from right sideis feasible.
Slide the electromagnetic lock to fit with the mounting plate as the drawing. Once the correct position is encountered, use the Allen Wrench to fasten the fixing screws through the bottom of the electromagnet lock into themounting plate.
After the electromagnet firmly assembled with the mounting plate, use the screws to fasten the lock on thesite permanently.
lll
GIANNI INDUSTRIES, INC.
No.306-1, Hsin Shu Road, Hsin Chuang, Taipei,Taiwan 242 TEL: 886-2-2206 9929 FAX: 886-2-2204 6632 E-Mail: info@gianni.com.tw Website: gianni.tw
Copyright © 2008 Gianni industries, inc.All rights reserved. DM-CA-EM-NH600 Ver. D Published on 2008.08.18
GP001
The products are manufactured under an ISO 9001 QC 080000 Certified Quality
&
Management Program environment back its product quality, performance and commitment to customersatisfaction.
Optional Brackets
Magnet
Armature
(On Power)
The door swinging direction and the door frame header are used to determine whether the bracket is required and this identify is a measure of which brackets is suitable. Our
optional brackets include L bracket LZ bracket and U bracket
.
With L-bracket for narrow door frames
When <42mm,must
"A"
installed with "L" brackets.
Door Frame
A
-,- -
L-NH300
EM-NH600 Mini Electromagnetic Lock
UBK-300-2
Frame
Suitable for use with frameless glass doors .After the door installs with the U­bracket, t he door will become a single swing (inward opening) The diagram shows the LZ-NH300N bracket installation instructions
Spacer
In-Swinging
UBK-300-2
Glass Door
Out-swinging
Door Leaf
Magnet
Armature
42 mm
With LZ-bracket for in-swinging doors
LZ-NH300N
With U-bracket for frameless glass doors
UBK-010 UBK-012
For 10mm thickness of glass door For 12mm thickness of glass door
Regular Installation
Unique Anti-Residual design
When the power is switched off, the holding force will be discontinuity and the bolt was installed in armature will pop out immediately. This design enables the door to be opened freely without any resistance.
Patent
ZL 2006 2 0122522.X (China) Nr. 20 2006 012 052.1(Germany) M308308 (Taiwan) GB 06 1 6099.8 (Great Britain) 06 07229 (France)
GIANNI INDUSTRIES, INC.
No.306-1, Hsin Shu Road, Hsin Chuang, Taipei,Taiwan 242 TEL: 886-2-2206 9929 FAX: 886-2-2204 6632 E-Mail: info@gianni.com.tw Website: gianni.tw
Copyright © 2008 Gianni industries, inc. All rights reserved. DM-CA-EM-NH600 Ver. D Published on2008.08.18
Warranty
The product is warranted against defects in material and workmanship while used in normal service for a period of 5 year from the date of sale to the original customer. The GEM policy is one of continual development and improvement; therefore GEM reserves the right to change specifications without notice.
The products are manufactured under an ISO 9001 QC 080000 Certified Quality
&
Management Program environment back its product quality, performance and commitment
GP001
to customersatisfaction.
Loading...