Gianni Industries Easiprox, P-MU-EASIPROX, EASIPROX-ANSI User Manual

EASIPROX
Waterproof Standalone Proximity Reader
I. Product Characteristic:
Easiprox has a 2000 cards capacity and a reading time of 0.5-second max.  Fully Programmable via Master card  Electronics potted with epoxy compound applications  Aesthetic and inconspicuous design  Suitable for fully weatherized indoor/outdoor  Non-volatile memory stores all programmed information for at least 10 years, even in the
II. Specifications:
event of total power failure.
Operating Voltage
Current Draw
Transmitting Frequency
Memory Volume
Read Range
Relay Electric Current
Relocking timer
Format
Case Material
Color
Operating Temperature
Ambient Humidity
Visual Signals
EMC
12Vdc or ac Average 45mA, Peak 70mA @ 12Vdc 125 KHz 2000 Proximity cards/tokens and PIN codes 10~15 cm (Depending on local installation conditions) 3A MAX @24Vdc Strike Time: 0.7~42 seconds (adjustable)
Em-400x 64-bit standard R/O or compatible
ABS (UL94V0)
Dark gray
-20~+70
5~95% relative humidity non-condensing
3 LED display with audible indication (Red/Yellow/Green)
Meet CE requirement
Copyright © Gianni Industries, Inc. All Rights Reserved. P-MU-EASIPROX Ver. B Published on 2008.02.12 Page: 1/ 4
III. The indicator signal chart:
Signal Condition
Yellow Power on, Stand-by
User Signals
Green Lock relay active
Red Invalid Card
YellowGreen Flashing
Green Flashing Into the ADD CARDS MODE
Programming
Signals
Red Flashing Into the DELETE CARDS MODE
YellowRed Flashing
Yellow Flashing Into the TIME ADJUST MODE
Green Blinking Clearing Memory
IV. Wiring diagram:
The memory is empty
Into the CLEAR MEMORY MODE
Power Supp ly
Push Button
(N.O./Com.)
Electric Strike
(Fail-Secure Typical)
Electric magnet
(Fail-safe Typical)
Note:
1. The suggested wire gauge is #22~26 AWG.
2. The varistor or diode must be connected across the lock terminal (electromagnet...) operated by the device. The vartistor controls the overload produced by the strike coil (EMP).
3. Using a Linear supply power recommended, to prevent power reduction at the card reader.
Copyright © Gianni Industries, Inc. All Rights Reserved. P-MU-EASIPROX Ver. B Published on 2008.02.12 Page: 2/ 4
V. Operation Instruction
WARNING: Please read all of operation instruction before proceeding.
Setting Master Card
If the GREEN and YELLOW lamps are flashing, it indicates that the memory is empty and that there is no Master Card. All programming is done by using this Master Card.
Add Cards
Read the Master Card once Only the GREEN lamp wills light Wait for the GREEN lamp to start flashing→ The Easiprox is now in the ADD state. In this state every Card presented to the Easiprox will operate the relay and be added to memory. Read the Master Card to return to the Stand-by state.
Delete Cards
Read the Master Card twice with a time between reads of less than 2 seconds The RED lamp will light Wait for the RED lamp to start flashing The Easiprox is now in the DELETE state.
In this state every Card that is presented to the reader will be deleted from the system memory. (Cards can now also be deleted by using the optional Card Simulator.). Once the Card or a group of Cards have been deleted, read the Master Card to return to the Stand-by state.
Clear Memory
Read the Master Card three times with a time between reads of less than 2 seconds The YELLOW and RED lamps will light Wait for the YELLOW and RED lamps to start flashing The Easiprox is now in the CLEAR MEMORY state.
Now present any Card except the Master Card to the reader and all memory will be cleared. Alternatively, read the Master Card to abort this function. Once the memory is cleared the YELLOW and GREEN lamps will flash to indicate that the memory is empty.
Totally reset
Power off Shorted the Clear Memory Black cable Power on Wait for the YELLOW and RED lamps to start flashingremove the black cable Once the memory is cleared the YELLOW and GREEN lamps will flash to indicate that the memory is empty.
Time Adjust
This function sets the relay operating time for a push-button input and a valid card read.
Read the Master Card 4 times with a time between reads of less than 2 seconds All the lamps will go off Wait for the YELLOW lamp to start flashing The Easiprox is now in the TIME ADJUST state and each flash of the YELLOW lamp equates to 0.7 second of relay operation time.
Once the desired time is reached (max 42 seconds), read the Master Card to store the time and return to the Stand-by state. If programming mode is required simply allow the YELLOW lamp to flash until it stops automatically (after 61 flashes). The unit will now be in programming mode.
Copyright © Gianni Industries, Inc. All Rights Reserved. P-MU-EASIPROX Ver. B Published on 2008.02.12 Page: 3/ 4
Card Simulator / Programmer (optional)
The Card Simulator allows adding and removing any card/card number from the reader memory when the card is lost or not available. One unit can be utilized at different sites but for security reasons it will operate only in conjunction with the Master Card.
The Card Simulator / Programmer cannot be used to gain access. It will only operate together with the reader's MASTER card
¾ Setting Card Number
Hold the On/Off button down.
Use the RIGHT ARROW key to move the cursor to the digit to be changed.
Use the UP ARROW key to change the number at the cursor.
Repeat the above until all the digits of the number are correct.
This number is stored in memory and the On/Off button may now be released.
¾ Battery
The unit is powered by a PP3 9V battery. Undo the 2 screws at the back of the unit to gain access to the battery.
¾ Deleting Cards
The MASTER card must be used to put the reader into the Delete mode.
RED lamp flashes
Place the Card Simulator close to the reader
Hold down the On/Off button and check the displayed number
Press the Send button
The GREEN lamp will flash to verify that the selected number is deleted and then the RED lamp will continue flashing.
Once the card or a group of cards have been deleted, read the Master Card to return to the RUN state.
¾ Adding Cards
The MASTER card must be used to put the reader into the Add mode.
GREEN lamp flashes
Place the Card Simulator close to the reader
Hold down the On/Off button and check the displayed number
Press the Send button
The GREEN lamp will go steady and the relay will operate to verify that the selected number is added. The GREEN lamp will then continue flashing.
Once the card or a group of cards have been added, read the Master Card to return to the stand-by state.
Copyright © Gianni Industries, Inc. All Rights Reserved. P-MU-EASIPROX Ver. B Published on 2008.02.12 Page: 4/ 4