Gianni Industries DG-5 User Manual

DG-5 The Digital Keyless Entry System
Operation User's Manual
1. Features:
Door Reed Switch Input for Anti-Trailing  10 user PINs  Fully Programmable via keypad and master code  Non-Volatile Memory Invalid PIN Lock-out
2. Specifications:
Operating Voltage: 9~14 Vdc  Current Draw: Average 20mA, Peak 70mA @ 12Vdc  Input: One request-to-exit, and time out reed switch  Relays: N.O./N.C./Com. Output (free voltage contact),
3A@ 125Vac or 30Vdc
Case Material: ABS (UL94V0)  Operating Temperature:-20~+70
Ambient Humidity:0~95% relative humidity non-
condensing
Visual Signals:
Green: Power on  Red: Relay activated  Yellow: Program Mode、Lock-out
Factory Master Code: 1234  Invalid PIN Lockout: System will shut down 60 seconds while 6 times of incorrectly
password attempted.
Relay Activation Time: (*20)
 Pulse mode1~99 seconds(01~99)  Latching mode(00)
EPROM: Non-volatile memory, System will retain all programs and codes after a total
loss of power.
User PINs: (*01~10It is possible to program 10 different user PIN codes.
3. Program Instruction:
Enter Program Mode:
1. Enter the master code twice (Factory master is 「1234」)
2 beeps and the Yellow LED will light up. you are now in the "programming mode".
2. Note: After 60 seconds if you have not entered any codes or data, the system will automatically exit from the programming mode. After 6 wrong attempts at the master code the lockout facility will operate.
Exiting from the program mode:
1. Press「#」 to exit from the programming mode.
Copyright Gianni Industries, Inc. All Rights Reserved. PMUDG5 Ver. A Publish:2004.08.26 Page: 1/ 2
2. Note: After 60 seconds if you have not entered any codes or data, the system will automatically exit from the programming mode. After 6 wrong attempts at the master code the lockout facility will operate.
To Enter a User Code
Enter the Programming mode
1. Enter the slot position code 「*01~*10」 ????(user code 4 digit(beep) enrolled Press # to exit from the programming mode, or program other operating.
2. Note: The codes"0000","1234" or master code are not be used for PIN code.
To Program Relocking Timerrelay): Enter the Programming mode
1. Press「*20」Followed by the number of seconds the relay should open「05」=5 seconds01 ~99 = secondsbeepenrolled Press 「#」 to exit from the programming mode, or program other operating.
2. Enter「00」Sets the relay to latching mode.
(Correct code entered opens the relay,
and the relay stays open until the correct code is entered again).
To Delete a User Code Enter the Programming mode Press the slot position code of your choice to delete
(example "06") →Press「*06「0000」(beep)→delete→Press「#」 to exit from the programming mode, or programming other operating.
To Change the Master codes:
Enter the Programming mode, Enter「*00」Followed by the new 4 digit master code beep→enrolledEnter # to exit from the programming mode, or program other operating.
4. Wiring diagram:
Tamper switch contact output
(fr ee vol ta ge co nta ct)
Power Supply
Com
NC
NO
Tam p er
Switch
Master Code
resetting(2-3)
to Factory
Code"1234"
Contact door reed switch
This reed switch is used
to reset the re-locking time
to 0 second when the door is moved.
(Using N.O. contact in case of door closed,
changeover to N.C. When door is moved)
Note:
FAIL-SAFE
LOCKING DEVICE
Push Button
12Vdc Power Supply
Diode
Buzzer
NO
Com
NC
P
B
REED REED
1
2
3
(Fail-secure locks)
(Fail-safe locks)
+
The varistor or diode must be connected across the lock terminal (electromagnet...) operated by the device. The vartistor controls the overload produced by the strike coil (EMP).
Copyright Gianni Industries, Inc. All Rights Reserved. PMUDG5 Ver. A Publish:2004.08.26 Page: 2/ 2