Gianni Industries DG-27, DG-25, DG-26 User Manual

The Digital Keyless Entry system
Operation User's Manual
1. Product Characteristic:
2. Specifications:
Operating Voltage: 12~24 Vdc  Current Draw: Average 15mA, Peak 60mA @ 12Vdc  Input: request-to-exit、Door Reed
Output: Dual relays, N.O./N.C./Com. Output (free voltage contact)  Relays Electric Current: 2A MAX @30Vdc ;0.4A @ 120Vac
Relay Activation Time: (*100、*200)
Strike Time: 1~99 seconds(adjustable) Strike mode: Access Timer or Latch
Memory Volume: 49+50 PIN codes
Relay 1 is controlled by 001~049 user slots
Relay 2 is controlled by 050~099 user slots  PIN codes: 5 digit codes only  Operating Temperature: -20~+70 Ambient Humidity: 5~95% relative humidity non-condensing  Factory Master Code: 12345  Invalid PIN Lock-out: The system will shut down for 60 seconds while 32 codes of
incorrectly Master Codes enrolled or PIN codes attempted. EPROM: Non-volatile memory, System will retain all programs and codes after a total
loss of power.
Copyright Gianni Industries, Inc. All Rights Reserved. P-MU-DG25 Ver. B Publish:2008.08.01 Page: 1/ 3
3. The indicator signal chart:
Sound and LED indicator:
Green LED Power on, stand-by
LED signal
Sound signal
Red LED Relay 1 activated
Yellow LED Relay 2 activated
1 Beep Effective PIN codes 2 Beeps 3 Beeps
5 Beeps
Entering Exiting from the Program mode Data computing error other operation mistakes Master Code reset to Factory (12345)
4. Operation Instruction:
Enter Program Mode:
1. Compose twice the master code (Factory master is 「12345」)
2 beeps you are now in the "programming mode".
2. After 60 seconds if you have not entered any codes or data, the system will automatically exit from the programming mode. After 32 wrong codes attempts at the master code the lockout facility will operate.
Exiting from the program mode:
1. Press「#」 to exit from the programming mode.
2. After 60 seconds if you have not entered any codes or data, the system will automatically exit from the programming mode. After 32 wrong codes attempts at the master code the lockout facility will operate.
Add PIN codes
Enter the Programming mode, Enter the slot position code 「*001~*099」→????? Input 5 digit PIN codes (beep) enrolled Æ(repeat) Press 「#」 to exit from the programming mode, or program other operating.
Note 1: The codes「00000」,「12345」or master code are not be used for PIN code.
Note 2: Relay 1 is controlled by 001~049 user slots, Relay 2 is controlled by 050~099
user slots
To Delete a User Code
Enter the Programming mode Press the slot position code of your choice to delete
(example "06") →Press「*006「00000」(beep)→delete→Press「#」 to exit from the programming mode, or programming other operating.
To Program Relocking Timer Enter the Programming mode,
A. Relay 1:Press「*100」Followed by the number of seconds the relay should
open05=5 seconds01 ~99 = seconds(beep)→enrolled → Press # to exit from the programming mode, or program other operating.
B. Enter「00」Sets the relay to latching mode.
and the relay stays open until the correct code is entered again).
C. Relay 2:Press「*200」Followed by the number of seconds the relay should
open05 =5 seconds (01 ~99 = seconds). beepenrolled Press # to exit from the programming mode, or program other operating.
D. Enter「00」Sets the relay to latching mode.
and the relay stays open until the correct code is entered again).
(Correct code entered opens the relay,
(Correct code entered opens the relay,
Copyright Gianni Industries, Inc. All Rights Reserved. P-MU-DG25 Ver. B Publish:2008.08.01 Page: 2/ 3
Loading...
+ 1 hidden pages