Gianni Industries DG-11 User Manual

The Digital Keyless Entry System (5 digit)
Operation User's Manual
DG-10
(Surface Mount)
DG-11
(Mount)
(Mount/ANSI size)
ANSI Box
I. Features:
5 digit codes  Door Reed Switch Input for Anti-Trailing  10 user PINs  Fully Programmable via keypad and master code  Non-Volatile Memory Invalid PIN Lock-out
II. Specifications:
Operating Voltage: 9~14 Vdc  Current Draw: Average 30mA, Peak 80mA @ 12Vdc  Input: One request-to-exit, and time out reed switch  Relays: N.O./N.C./Com. Output (free voltage contact), 3A@ 125Vac or 30Vdc  Case Material: ABS (UL94V0)
 Operating Temperature:-20~+70 Ambient Humidity:0~95% relative humidity non-condensing  Visual Signals:
Green: Power on  Red: Relay activated  Yellow: Program Mode、Lock-out
Factory Master Code: 12345  Invalid PIN Lockout: System will shut down 60 seconds while 6 times of incorrectly
password attempted.
Relay Activation Time: (*20)
 Pulse mode1~99 seconds(01~99)  Latching mode(00)
EPROM: Non-volatile memory, System will retain all programs and codes after a total
loss of power.
User PINs: (*01~10It is possible to program 10 different user PIN codes.
Copyright Gianni Industries, Inc. All Rights Reserved. P-MU-DG10-5C Ver. A Publish:2004.09.07 Page: 1/ 2
III. Program Instruction:
Enter Program Mode:
1. Enter the master code twice (Factory master is 「12345」)
2 beeps and the Yellow LED will light up. you are now in the "programming mode".
2. Note: After 60 seconds if you have not entered any codes or data, the system will automatically exit from the programming mode. After 6 wrong attempts at the master code the lockout facility will operate.
Exiting from the program mode:
1. Press「#」 to exit from the programming mode.
2. Note: After 60 seconds if you have not entered any codes or data, the system will automatically exit from the programming mode. After 6 wrong attempts at the master code the lockout facility will operate.
To Enter a User Code
Enter the Programming mode
1. Enter the slot position code 「*01~*10」 ?????(user code 5 digit(beep) enrolled Press # to exit from the programming mode, or program other operating.
2. Note: The codes"00000","12345" or master code are not be used for PIN code.
To Program Relocking Timerrelay): Enter the Programming mode
A. Press「*20」Followed by the number of seconds the relay should open「05」
=5 seconds01 ~99 = seconds(beep)→enrolled → Press 「#」 to exit from the programming mode, or program other operating.
B. Enter「00」Sets the relay to latching mode.
(Correct code entered opens the relay,
and the relay stays open until the correct code is entered again).
To Delete a User Code Enter the Programming mode→ Press the slot position code of your choice to delete
(example "06") →Press「*06「00000」(beep)→delete→Press「#」 to exit from the programming mode, or programming other operating.
To Change the Master codes:
Enter the Programming mode, Enter「*00」Followed by the new 5 digit master code beep→enrolledEnter # to exit from the programming mode, or program other operating.
IV. Wiring diagram:
12Vdc Power Supply
FAIL-SAFE LOCKING
DEVICE
This reed switch is used
to reset the re-locking time
to 0 second when the door is moved.
(Using N.O. contact in case of door closed,
changeover to N.C. When door is moved)
V
Var ist or
Push Button
1 2 3
Power in(Red)
Power in(Red)
N.O.(Yellow)
Com.(Green)
N.C.(Blue)
P(White)
B(White)
Contact door reed switch (Pink)
1 2 3
Master Code
resetting to
Factory Code
"12345"
Buzzer
Relay
Note:
The varistor or diode must be connected across the lock terminal (electromagnet...) operated by the device. The vartistor controls the overload produced by the strike coil (EMP).
Copyright Gianni Industries, Inc. All Rights Reserved. P-MU-DG10-5C Ver. A Publish:2004.09.07 Page: 2/ 2