Gianni Industries BTS-486 User Manual

Specifications
BTS Touch Exit Button Installation Instruction
Mode Operating Voltage
Current Draw Relay contact
output Relay rating
Relay strike time LED status
indication Temperature
Other
BTS-100 BTS-115-ANSI,115-S BTS-400ANSI,300BTS-85UK BTS-486
12~24VDC 12~24VDC 12~24VDC 12~24VDC 12~24VDC
30~60mA/12VDC 40~80mA/24VDC
Com,N/C,N/O Com,N/C,N/O Com,N/C,N/O Com,N/C,N/O Com,N/C,N/O
3A/30VDC 3A/24VDC 3A/24VDC 3A/24VDC 3A/24VDC
1~30 seconds
-20~+70ºC
30~50mA/12VDC 40~60mA/24VDC
1~30 seconds
-20~+70ºC
Wiring Diagram
The BTS touch sensitive exit button has N.O. and N.C. contact output and can be connected directly to a electromagnetic lock or a proximity reader in series (or in parallel).
20~40mA/12VDC 20~50mA/24VDC
1~30 seconds 1~30 seconds 1~30 seconds
-20~+70ºC -20~+70ºC
Control Device (Outdoor)
Relay output control
60~100mA/12VDC 80~120mA/24VDC
2x6 levels of LED indicator
30~60mA/12VDC 40~80mA/24VDC
2x6 levels of LED indicator
-20~+70ºC
N/O,N/C output setting
Fig.A
In Fig.A, BTS controls the fail-safe locking device directly by series connection. BTS relay time is door-opening time.
Power
1
30 sec.
Relay Timer
Locking Device
(fail-safe)
Supply
BTS Touch Sensitive Switch (Indoor)
Control Device (Outdoor)
Fig.B
In Fig.B, BTS controls the fail-secure locking device directly by parallel connection. BTS
Relay output control
relay time is door-opening time.
Locking Device
(fail-secure)
Power
1
30 sec.
Relay Timer
Supply
BTS Touch Sensitive Switch (Indoor)
Note:
1. Make sure that the power input and relay rating output (3Amp/24VDC) are correct.
2. Make sure that the “+” and “-” wires are connected correctly.
3. The door strike or relay must have a varistor or a diode across the door strike terminals to suppress the back EMF of the strike. Failure to do so will damage the relay contacts and electronic omponents, or even burn the controller.
Copyright © GIANNI Industries,Inc.All rights reserved. P-MU-BTS Ver.D Published 2011.03.18
Illustration
BTS Touch Exit Button
Base Slot hole
LED
Vandal resistant screw Stopper Touch panel
JP setting
The relay will send the signals from N.C. into N.O. contact after your finger or a metal object touches the touch panel. Time delay can be adjusted from 1 to 30 seconds.
Relay output
Relay output
(Light stay on)
(Light flash)
(Green)
(Red)
(Green)
(Off)
(Red)
(Off)
(Touch)
(Touch)
(Touch)
(Touch)
(Touch)
(Touch)
(Touch)
(Touch)
Relay output
Relay output
(Red)
(Green)
(Off)
(Green)
(Off)
(Red)
BTS-400-ANSI,300,486
Relay contact output
(dry contact)
12~24 VDC power input
JP setting
Relay Timer
(Sec.)
Warranty
The product is warranted against defects in material and workmanship while used in normal service for a period of 1 year from the date of sale to the original customer. The GEM policy is one of continual development and improvement; therefore GEM reserves the right to change specifications without notice.
Copyright © GIANNI Industries,Inc.All rights reserved. P-MU-BTS Ver.D Published 2011.03.18
Loading...