Gianni Handle Lock Series, PH-450, PH-900 Installation Instruction

Page 1
Electromagnetic Lock Installation Instruction
Connecting Diagram
SPDT relay
3A/12VDC
Power
Input
N.C.
N.O.
-
+
-
+
12VDC
24VDC
PH-450/ PH-900 Handle Lock Series
Website: www.gianni.com.tw E-mail: info@gianni.com.tw
Zinc plated
Current Draw
Technical Specification
Operating Voltage
(at temperature 20ºC)
Operating Temperature Relay Rating
Holding Force
Lock Surface Temperature
ambient temperature ±20˚C
PH-450: 600 lbs
Special Finishes for magnet and armature plate
Trigger
Relocking timer (PH-450MTD)
The door will lock automatically after the circuit trigger connects to each other. VR timer adjustable up to 30 seconds.
Magnet bond sensor output
(PH-450M)
Power supply
N.C. contact of control Device / Access Relay
Timer Adjustment
Shorten
Voltage Selection Jumpers Check jumper settings before
connecting the lock to input power. Incorrect jumper settings may cause or result in damage of the lock.
Lock & unlock status
Notice that PH-450/PH-900 series of maglocks should be installed on “inswing” doors and frames for the sake of security.
Installing the maglock on outswing doors/frames will pose security problems.
I
n
s
w
i
n
g
O
u
t
s
w
i
n
g
Armature Plate
Rubber Washer
Upper Case
Handle
Trimming plate
Fixing Screw
Bottom case
Armature Assembly Magnet Assembly
Tamper Screw
Electromagnetic Lock
Tool Kit Blind Nuts
Tool
Dimensions & Accessories
I
n
s
w
i
n
g
-10~55°C(14~131°F) 3A/12VDC
250mA/24VDC
PH450:12/24VDC PH900:12/24VDC x2
PH450:500mA/12VDC
250mA/24VDC x2
PH900:500mA/12VDC x2
Specification
PH-900: 600 lbs x2
(approx. 272 kg x2)
(approx. 272 kg)
Page 2
Regular Installation
Installation Instruction:
Close the door and make sure the door and the door frame are at the same
Drill 9.4mm holes for M6 Blind Nuts.
allen wrench
Insert the Blind Nut into fixing screw and separate holes.
Use the allen wrench . to slowly tighten the Blind Nut. (Don’t tighten the nuts too firmly.)
Keep wrenching the Blind Nut so that it remains permanently fixed in the
frame. Remove the tool.
12mm CABLE HOLE
9.4mm BLIND NUTS
MAGNET ASSEMBLY
9.4mm BLIND NUTS
ARMATURE ASSEMBLY
Door
Frame
Important Notes
The electromagnetic lock is fail­safe and will require a power supply unit equipped with battery back up for fear that power failure may increase security risks.
Do not install a diode or MOV in parallel with any magnetic lock. A diode will cause a delay when releasing the door.
Apply a light coat of a silicon Iubricant to prevent the maglock from rusting. Wipe off the excess.
Do not strand power wires and signal wires in the same cable or conduit.
Trouble Shooting
Problem
Door does not lock
No power
Reduced holding froce
Poor contact between electromagnet and armature plate
Low voltage or incorrect voltage setting
Sensor output is not functioning
A secondary diode was installed across the electromagnet
Misalignment between the armature plate and its magnet
Possible Cause
Solution
Make sure the wires are securely tightened to the correct terminal block Check that the power supply unit is connected and operating properly Make sure the lock switch is wired correctly Make sure the surface of the armature plate is in good shape
Make sure the rubber washer is inserted behind the armature plate Make sure the contact surfaces of the electromagnet and armature plate are clean
and free from dust Check the setting of power input volume
Check the settings of the voltage / current volume on the terminals of the maglock Remove any diode installed across the magnet for “spike”
suppression. (The magnet is fitted with a metal oxide varistor to prevent back EMF) Check the faces of armature plate and the maglock are aligned face-to-face
level of height; otherwise, it is necessary to add extra iron boards to make
Stick the templates to the corresponding positions on the door and frame.
Drill the holes for cables and screws according to the templates.
Fix the blind nuts (see illustration below) to secure the maglock.
Wire the maglock.
Fix the armature plate. Plug in the maglock. Close the door and test the
Power
Input
Power
N.O. COM. N.C.
Power
Input
SPDT relay
3A/12VDC
F
2
1
3
4
5
6
the door or the door frame at the same level.
installation.)
(Make sure the gap between the door and frame is within the limit set by
holding force. Add rubber washers if necessary to adjust the gap between
the armature plate and maglock.
wrench
Copyright © All Rights Reserved. P-MU-PH-450-900 Ver.A Publish: 2011.07.28