+GF+ 2282 User guide

Page 1
Category
Value
Material Enclosure and float
2282-P-XXX
Polypropylene (PP)
2282-V-XXX
Polyvinylidene fluoride (PVDF)
Thread
2282-X-XXB
G ½
2282-X-XXN
½ NPT
Maximum temperature
PP version
80°C
PVDF version
100°C
Maximum pressure
10 bar
Mounting position
Horizontal, ±30° from the horizontal
Contact
NO/NC contact as per mounting position
Electrical connection
PVC cable, 2-wire, with AWG 20 stranded wire
PVC cable, DIN plug
Maximum switching values
230 V
AC/DC
Max. 40 VA, max. 2 A
Resistance
Max. 80 mΩ
Maximum dielectric strength
400 VDC/1 s
Medium density
PP version
>0.6 kg/dm3
PVDF version
>0.95 kg/dm3
Protection rating
IP68
l1
68 mm
l3
15 mm
1
G ½ or ½-14 NPT
l2
81 mm
d
ø 17.5 mm
2
Tank wall
Normally open
Normally closed
GF Piping Systems
Instruction manual
2282 Guided float switch
Georg Fischer Piping Systems Ltd 8201 Schaffhausen, Phone +41(0)52 631 30 26 / info.ps@georgfischer.com / www.gfps.com
GFDO_6377_4 (07.14)
© Georg Fischer Rohrleitungssysteme AG 8201 Schaffhausen / Switzerland, 2014 Printed in Switzerland
Observe instruction manual The instruction manual is part of the product and an important element within the safety
concept.
Read and observe the instruction manual. Always have the instruction manual available at the product. Pass on the instruction manual to all subsequent users of the product.
1 Intended use
Float switch 2282 is used to monitor the level of liquids to which the materials used are resistant and which are compliant with the specified medium density.
2 About this document
This document contains all necessary information for the installation, operation, and maintenance of the product.
3 Safety and responsibility
Only use the product as intended, see intended use. Do not use the product if it is damaged or faulty. Throw out the product immediately
if it is damaged.
Make sure that the piping system has been installed professionally and that it is
inspected regularly.
The product must only be installed by persons who have the required training,
knowledge, and experience.
Regularly train personnel on all questions pertaining to the locally accepted
regulations on occupational safety and environmental protection, especially on pressure-retaining pipelines.
The personnel is responsible for the following measures: Know, understand and follow the instruction manual and the advices therein.
4 Delivery contents
2282 Guided float switch Instruction Manual
5 Transport and storage
Protect the product against external force during transport (impact, stroke,
vibrations, etc.).
Transport and/or store the product in unopened, undamaged original packaging. Protect the product from dust, dirt, moisture as well as heat and ultraviolet
radiation.
Ensure that the product has not been damaged by either mechanical or thermal
influences.
Check the product for transport damage before assembly.
6 Function
Float switch 2282 is designed to enable economical monitoring of liquids in tanks. It is available in two different plastic versions, both of which have two different attachments for several application options. Further advantages are its maintenance-free design, compact size, and the high switching capacity of the reed contacts.
The float switch is installed horizontally in the tank. The plastic float switch has a welded-in magnet and moves up and down on a hinge
to monitor the level of liquid in the tank.
In the end position, the welded-in magnet actuates the embedded, potential-free
reed contact.
The mounting position determines whether the normally open/normally closed
switching function is applied. This can be altered by turning the product 180°.
7 Technical Data
8 Dimensions
9 Installation
Checking the installation conditions
No free-floating solids or ferritic parts are present in the liquid, as these can cause
the float switch to malfunction.
If the liquid contains sediment or particulate matter, appropriate precautions must
be taken to keep these away from the float switch.
Are the maximum working pressure and maximum temperature values being
observed?
Checking the mounting position
The float switch must be able to move freely along the entire path length. It should not touch either the walls, bottom, or lid of the tank. Ensure that there is no turbulence from inlet valves or agitators. If possible, install the product in an easily accessible position. This makes
subsequent maintenance and replacement work easier.
The product should be installed horizontally. Check whether the product has been installed in the normally open or normally
closed position.
Mounting position
Installing the float switch mechanically
The float switch cable must not be connected. Make sure that the thread in the tank is free of contamination. Carefully insert the float switch into the opening and turn it several revolutions by
hand.
With a maximum torque of 4 Nm, tighten the float switch until the flattened side
edges are as vertical as possible.
Check whether the correct mounting position (NO/NC) has been achieved. Check whether the connection is tight. In the event of a leak, remove the sensor again completely and remount it using
additional sealing materials (e.g., PTFE tape).
Page 2
The float switch is insulated, therefore a separate grounding wire is not required. Ensure that the voltage values for the float switch
correspond to those for the system.
Make sure that the supply cable is de-energized. Connect the connection cable for the float switch to the
supply cable.
Connect external devices.
- The float switch is operational once the supply voltage has
been switched on.
You can check that the switching output is working correctly
by manually raising and lowering the float.
Configuration
1
Brown
2
Black Art. no.
Type
Designation
159 300 260
2282-P-6OB
PP enclosure, DIN plug, ½" BSP
159 300 261
2282-P-6CB
PP enclosure, cable, ½" BSP
159 300 262
2282-V-6OB
PVDF enclosure, DIN plug, ½" BSP
159 300 263
2282-V-6CB
PVDF enclosure, cable ½" BSP
159 300 264
2282-P-6ON
PP enclosure, DIN plug, ½" NPT
159 300 265
2282-P-6CN
PP enclosure, cable, ½" NPT
159 300 266
2282-V-6ON
PVDF enclosure, DIN plug, ½" NPT
159 300 267
2282-V-6CN
PVDF enclosure, cable, ½" NPT
Media that is detrimental to people's health and the environmental may escape! Risk of personal injury or damage to the environment caused by these media.
Wear the prescribed protective clothing. Collect any media that escapes and dispose of it in accordance with local regulations.
Consult the safety data sheet.
Parts of the product may be contaminated with media that are harmful to health and the environment meaning that simple cleaning is not sufficient! Risk of personal injury and damage to the environment caused by these media. Prior to disposing of the product: Collect leaking media and dispose of it according to the local regulations. Consult
the safety data sheet.
Neutralize any media residue that is present in the product. Separate materials (plastics, metals, etc.) and dispose of them according to the
local regulations.
A product marked with this symbol must be sent for separate collection of electrical and electronic devices. If you have questions regarding the disposal of the product, please contact your national GF Piping Systems representative.
Georg Fischer Piping Systems Ltd 8201 Schaffhausen, Switzerland Phone +41(0)52 631 30 26 / info.ps@georgfischer.com / www.gfps.com
6377_4 (07.14)
© Georg Fischer Rohrleitungssysteme AG 8201 Schaffhausen / Switzerland, 2014 Printed in Switzerland
CAUTION
CAUTION
Connecting the float switch electrically
13 Disclaimer
The technical data are not binding. They neither constitute expressly warranted characteristics nor guaranteed properties nor a guaranteed durability. They are subject to modification. Our General Terms of Sale apply.
10 Ordering information
11 Dismantling
Make sure that the connection cable is de-energized and can be freely rotated. Make sure that the tank is depressurized and has been drained to a level that is at
least below that of the sensor mounting position.
12 Disposal
Before disposing of the different materials, separate them into recyclables, normal
waste, and special waste.
Comply with local legal regulations and provisions when recycling or disposing of
the product, the individual components, and the packaging.
Comply with national regulations, standards, and guidelines.
Loading...