+GF+ 2260 User guide

Page 1
2260 Ultrasonic Level Transmitters with Ex Approval
Features
• 2-wire compact transmitters
• Non-contact level metering
• Narrow 5° beam angle
• Level, volume and open channel fl ow
• Fully temperature compensated electronics
• Outstanding signal processing software providing highly accurate measuring results
• Quick-set menu for e cient installation
The type 2260 is a rugged, high performance ultrasonic level measurement transmitter, having transducer and processing electronics and a display/programming unit incorporated in one single housing.
All type 2260 Level Transmitters are using established high end pulse echo transducers, which provide narrow beam angles and reliable measurement ranges up to a distance of 15 meters (49.2 ft).
For small, stand alone tanks the transmitter provides a simple 2-wire 4 to 20 mA output, with additional power relay contacts. It can be programmed using push buttons and the large, graphic display. For large and/or multiple tank applications versions with HART interface are recommended, communicating directly with a panel mount controller or PLC. The HART protocol can easily be used for programming these versions.
For hazardous areas the type 2260 Level Transmitters are available with explosion proof approvals.
• Plug-in keypad and display
• 4 to 20 mA / HART interface (Optional)
• Secondary lightning protection
• Intrinsically safe (Option)
• 32-point linearization
Applications
• River water
• Seawater
• Potable water
• Demineralized water
• Treated water
www.gfps.com/level
Page 2
Dimensions (mm)
2-wire level transmitters
2 x M20x1.5
2 x 1/2” NPT
2260-Y-YYY-8
2” BSP or NPT
Ø54
~148
80±1
2260-Y-YYY-15
89 mm (3.5 in)
122 mm
(4.8 in)
(3.84 in)
97.5 mm
19 mm
2260-Y-YYY-4 2260-Y-YYY-6
89 mm (3.5 in.)
60 mm
(2.36 in.)
BSP length 15 mm (0.59 in.) NPT length 22 mm (0.87 in.)
(3.84 in.)
97.5 mm
89 mm (3.5 in.)
60 mm
(2.36 in.)
BSP length 15 mm (0.59 in.) NPT length 22 mm (0.87 in.)
97.5 mm
(3.84 in.)
BSP 15 mm (0.59 in.) NPT 22 mm (0.87 in.)
Specifi cations
General
Type 2260-Y-YYYX-4 2260-Y-YYYX-6 Range 0.2 to 4 m
(0.65 to 13 ft)
0.25 to 6 m
(0.82 to 20 ft) Measuring Frequency 80 kHz 80 kHz Total Beam Angle
2260-Y-YYY-8
0.35 to 8 m
(1.1 to 26 ft)
50 kHz
Accuracy * ± (0.2 % of measured distance plus 0.05 % of range) Resolution <2 m (6.6 ft): 1 mm (0.04 in.), 2 to 5 m (6.6 to 16.4 ft), 2 mm (0.08 in.),
5 to 10 m (16.4 to 32.8 ft): 5 mm (0.2 in.), >10 m (32.8 ft): 10 mm (0.39 in.)
Environmental
Process Temperature
PP sensor -20 °C to +70 °C (-4 °F to 158 °F)
PVDF sensor -20 °C to +80 °C (-4 °F to 176 °F) Ambient Temperature -20 °C to +60 °C (-4 °F to 140 °F) Process Pressure (absolute) 0.03 to 0.3 MPa (0.3 to 3 bar) 4.35 psi - 43.5 psi
Enclosure
Enclosure Material
Sensor Body PP or PVDF
Housing PBT Ingress Protection
Sensor IP68, NEMA 6P
Housing IP67, NEMA 6P Process Connection 1 1/2” BSP / NPT 2” BSP / NPT DN125 / 5 inch fl ange Sealing
PP sensor EPDM
PVDF sensor FPM (Viton)
Electrical
Outputs 2- wire 4–20 mA , HART interface, Rt >/= 250 Ω Power Supply 12 to 30 V DC, Note: Ex-devices must be powered by EEx ia power supplies Power Supply Loading Uo < 30 V, Io < 140 mA, Po < 1 W, Rt max = (Us - 12 V) / 0,02 A
Intrinsically safety data Ci </= 15 nF, Li </= 200 μH, Ui </= 30V, Ii </= 140 mA, Pi </= 1 W
Connection 2 x M20x1,5 metal cable gland: Cable: Ø7 … 13 mm
Standards and Approvals
General Approvals CE, RoHS ATEX Approval ATEX II 1 G EEx ia IIB T6, IP68, NEMA 6P
2260-Y-YYYX-15
0.45 to 15 m (
1.5 to 49 ft) 40 kHz
(0.75 in)
43 mm
(1.69 in)
* Under optimal circumstances of refl ection and stabilized transducer temperature
www.gfsignet.com
Page 3
Display Unit
(2)
(1)
(12) (11)
(10)
(9)
(8)
(3)
(7)
(1) Primary measured value (2) Measurement mode (3) Measurement unit / Standard (4) Bar graph trend indication (5) Measurement error indication
(4)
(6) Liquid movement direction (7) Time unit
(5)
(8) Presence of valid echo (9) HART communication
(6)
(10) Temperature unit (11) Relay status indication (12) Programming mode indication
2260 Transmitter Terminals
HART Interface Wiring
123456
5ȍ
4 to 20 mA loop
+
Power Supply
-
4 to 20 mA Loop Wiring
123456
+
4 to 20 mA loop
mV test
10mV = 1 mA
Power Supply (polarity
-
irrelevant)
Wiring to 9900 Universal Transmitter
White
+
Power
Black
Black
Brown
-
4 to 20 mA loop
4-20 mA
Input
Red
Shield
Supply
+GF+
Signet 8058 i-Go™
4-20 mA to S
4-20 mA input S3L Output
8058-1
3
L Converter
Output
L
3
S
9900 S3L Terminals
Black Red
White
Shield
V+
SHLD
DATA
GND
www.gfsignet.com
HART
Modem
USB Interface
PC
Page 4
Ordering Information
Mfr. Part No Code Description
2260-P-0DN-4 159 300 120 Range 4 m (13.1 ft), PP body, 4..20 mA 2-wire, NPT thread
2260-P-2DN-4 159 300 121 Range 4 m (13.1 ft), PP body, 4..20 mA 2-wire/relay/HART, NPT thread
2260-P-0DN-6 159 300 122 Range 6 m (19.7 ft), PP body, 4..20 mA 2-wire, NPT thread
2260-P-2DN-6 159 300 123 Range 6 m (19.7 ft), PP body, 4..20 mA 2-wire/relay/HART, NPT thread
2260-P-0DN-8 159 300 109 Range 8 m (26.2 ft), PP body, 4..20 mA 2-wire, NPT thread
2260-P-0DA-15 159 300 124 Range 15 m (49.2 ft), PP body, 4..20 mA 2-wire, ANSI Flange 5 inch
2260-P-2DA-15 159 300 125 Range 15 m (49.2 ft), PP body, 4..20 mA 2-wire/relay/HART, ANSI Flange 5 in.
2260-V-0DN-4 159 300 131 Range 4 m (13.1 ft), PVDF body, 4..20 mA 2-wire, NPT thread
2260-V-2DN-4 159 300 132 Range 4 m (13.1 ft), PVDF body, 4..20 mA 2-wire/relay/HART, NPT thread
2260-V-0DN-6 159 300 133 Range 6 m (19.7 ft), PVDF body, 4..20 mA 2-wire, NPT thread
2260-V-2DN-6 159 300 134 Range 6 m (19.7 ft), PVDF body, 4..20 mA 2-wire/relay/HART, NPT thread
2260-V-0DN-8 159 300 110 Range 8 m (26.2 ft), PVDF body, 4..20 mA 2-wire, NPT thread
2260-V-0DA-15 159 300 135 Range 15 m (49.2 ft), PVDF body, 4..20 mA 2-wire, ANSI Flange 5 inch
2260-V-2DA-15 159 300 136 Range 15 m (49.2 ft), PVDF body, 4..20 mA 2-wire/relay/HART, ANSI Flange 5 in.
Versions with NPT thread / ANSI fl ange
2260-V-1DNX-4 159 300 142 Range 4 m (13.1 ft), PVDF body, 4..20 mA 2-wire/HART, ATEX, NPT thread
2260-V-1DNX-6 159 300 143 Range 6 m (19.7 ft), PVDF body, 4..20 mA 2-wire/HART, ATEX, NPT thread
2260-V-1DAX-15 159 300 144 Range 15 m (49.2 ft), PVDF body, 4..20 mA 2-wire/HART, ATEX, ANSI Flange 5 in.
Versions with BSP thread / DIN fl ange
2260-P-0DB-4 159 300 090 Range 4 m (13.1 ft), PP body, 4..20 mA 2-wire, BSP thread 2260-P-2DB-4 159 300 091 Range 4 m (13.1 ft), PP body, 4..20 mA 2-wire/relay/HART, BSP thread
2260-P-0DB-6 159 300 092 Range 6 m (19.7 ft), PP body, 4..20 mA 2-wire, BSP thread 2260-P-2DB-6 159 300 093 Range 6 m (19.7 ft), PP body, 4..20 mA 2-wire/relay/HART, BSP thread 2260-P-0DB-8 159 300 107 Range 8 m (26.2 ft), PP body, 4..20 mA 2-wire, BSP thread 2260-P-0DF-15 159 300 094 Range 15 m (49.2 ft), PP body, 4..20 mA 2-wire, DIN Flange DN125 2260-P-2DF-15 159 300 095 Range 15 m (49.2 ft), PP body, 4..20 mA 2-wire/relay/HART, DIN Flange DN125
2260-V-0DB-4 159 300 101 Range 4 m (13.1 ft), PVDF body, 4..20 mA 2-wire, BSP thread
2260-V-2DB-4 159 300 102 Range 4 m (13.1 ft), PVDF body, 4..20 mA 2-wire/relay /HART, BSP thread 2260-V-0DB-6 159 300 103 Range 6 m (19.7 ft), PVDF body, 4..20 mA 2-wire, BSP thread 2260-V-2DB-6 159 300 104 Range 6 m (19.7 ft), PVDF body, 4..20 mA 2-wire/relay /HART, BSP thread 2260-V-0DB-8 159 300 108 Range 8 m (26.2 ft), PVDF body, 4..20 mA 2-wire, BSP thread 2260-V-0DF-15 159 300 105 Range 15 m (49.2 ft), PVDF body, 4..20 mA 2-wire, DIN Flange DN125
2260-V-2DF-15 159 300 106 Range 15 m (49.2 ft), PVDF body, 4..20 mA 2-wire/relay/HART, DIN Flange DN125
Ordering Information
Mfr. Part No Code Description
Versions with BSP thread / DIN fl ange
2260-V-1DBX-4 159 300 112 Range 4 m (13.1 ft), PVDF body, 4 to 20 mA 2-wire/HART, ATEX, BSP thread
2260-V-1DBX-6 159 300 113 Range 6 m (19.7 ft), PVDF body, 4 to 20 mA 2-wire/HART, ATEX, BSP thread
2260-V-1DFX-15 159 300 114 Range 15 m (49.2 ft), PVDF body, 4 to 20 mA 2-wire/HART, ATEX, DIN Flange
Accessories
Code Description
159 300 181 HART - USB Modem
159 300 182 HART - USB Modem, DIN Rail
159 300 183 HART - USB Modem, DIN Rail, ATEX
159 300 180 Display unit for type 2260 Transmitter
Rev E (05/17)