GEZE GC 363 R, GC 363 SF Operating Instructions Manual

GC363 R / SF
151263-01
42.8438 v1 - 01-2015
GC 363 R / SF
Contents
Symbols and illustrations ................................................................................. 3
Abbreviations ....................................................................................................... 3
Product liability....................................................................................................3
1 Safety .......................................................................................................... 3
1.1 Intended use ........................................................................................................................3
1.2 Safety notices .....................................................................................................................4
1.3 Safety conscious working ...............................................................................................5
1.4 Environmentally conscious working ...........................................................................5
2 Description ...............................................................................................5
2.1 Supplied by GEZE ...............................................................................................................7
3 Work to be done before installation ................................................ 8
3.1 Installing the drive .............................................................................................................8
3.2 Protection sensor ...............................................................................................................9
4 Installation ............................................................................................. 10
4.1 Installation without accessories ................................................................................ 10
4.2 Installation with ceiling installation set .................................................................. 11
4.3 Installation with mounting bracket..........................................................................13
4.4 Installation with weather canopy ............................................................................. 14
4.5 Cabling ................................................................................................................................15
5 Commissioning .................................................................................... 16
5.1 Radar detector ................................................................................................................. 16
5.2 Protection area.................................................................................................................18
5.3 Settings ...............................................................................................................................19
5.4 Teaching .............................................................................................................................20
6 Conguration possibilities ............................................................... 20
6.1 Using the LCD menu ...................................................................................................... 20
6.1.1 Display during normal function ................................................................................ 20
6.1.2 Menu navigation ............................................................................................................. 20
6.1.3 Changing ZIP code ......................................................................................................... 21
6.1.4 Changing and storing values ......................................................................................21
6.1.5 Checking values using the remote control............................................................21
7 Settings ................................................................................................... 21
7.1 Default settings ............................................................................................................... 21
8 Last installation steps ......................................................................... 25
9 Further installation situations ......................................................... 26
9.1 Single leaf installation ................................................................................................... 26
9.2 Lintel installation .............................................................................................................27
10 Maintenance ......................................................................................... 28
2
11 Error messages and troubleshooting ........................................... 28
12 Technical data ....................................................................................... 31
13 Accessories / Spare parts .................................................................. 33
Symbols and illustrations
Warning notices
Warning notices are used in these instructions to warn you of property damage and personal injury.
X
Always read and observe these warning notices.
X
Observe all the measures that are marked with the warning symbol and warning word .
Abbreviations
FR Escape and rescue routes IR Infrared AIR Active infrared control RAD Radar LCD Liquid Crystal Display HSK Main closing edge NSK Secondary closing edge
SafetyGC 363 R / SF
Product liability
In accordance with the liability of the manufacturer for his products as dened in the German "Product Liability Act", the information contained in this brochure (product information and proper use, misuse, product performance, product maintenance, obligations to provide information and instructions) is to be observed. Failure to comply releases the manufacturer from his statutory liability.
1 Safety
1.1 Intended use
The combined sensor GC 363 may only be used to actuate and safeguard automatic sliding doors and circular sliding doors with GEZE drives. The minimum object size corresponds to the reference object CA according to DIN 18650 or 16005 both upright and lying down. The sensor can be used to secure automatic sliding doors against impact and trapping of the human body.
3
Safety GC 363 R / SF
GC363 R
GC363 SF
(in the direction of
1.2 Safety notices
à The mandatory installation, maintenance and repair work must be per-
formed by properly trained personnel authorised by GEZE. Any attempts at repairs by unauthorised personnel cancel the factory guarantee.
à The device may only be operated with safety extra-low voltage (SELV)
with electrically protective separation.
à The country-specic laws and regulations are to be observed during
safety-related tests. à Make sure that the door control cover is tted correctly and earthed. à If unauthorised changes are made to the system, GEZE cannot be held
liable in any way whatsoever for any resulting damage, and the approval
for use in escape and rescue routes ceases. à GEZE makes no guarantee for combinations with third-party products. à Only original GEZE parts may be used for repair and maintenance work. à Observe the latest versions of directives, standards and country-specic
regulations, in particular:
à ASR A1.7 "Doors and gates" à DIN 18650 "Building hardware – Automatic door systems" à DIN EN 16005 "Power operated pedestrian doorsets – Safety in use –
Requirements and test methods"
à Accident-prevention regulations, especially BGV A1 "General regula-
tions" and BGV A2 "Electrical systems and equipment".
à The risk assessment and installation of the sensor and the door system in
compliance with national and international regulations and door safety
standards are the responsibility of the door manufacturer. à Any uses of the device other than those described in this manual do not
correspond to the approved purpose and cannot be guaranteed by the
manufacturer.
emergency exit)
4
1.3 Safety conscious working
à Secure workplace against unauthorised entry. à Watch swivelling range of long system parts. à Secure the cover/drive panels against falling. à Attach safety stickers to glass door leaves. à Danger of injury with opened drive. Hair, clothing, cables, etc. can be
drawn in by rotating parts. à Danger of injury caused by unsecured crushing, impact, drawing-in or
shearing spots. à Danger of injury due to broken glass. à Danger of injury due to sharp edges in the drive. à Danger of injury during installation through freely moving parts.
1.4 Environmentally conscious working
à When disposing of the door system, separate the dierent materials and
have them recycled.
2 Description
The combined detectors GC 363 R / SF have a radar eld for detecting movement and an infrared eld for protection. It is not possible for several systems to inuence each other and result in a hazard. Unintentional stop signals are possible where detectors are mount­ed next to one another as their infrared measuring ranges overlap and each sensor could activate the other. This inuence is kept to a minimum by dierent frequency settings. The optional interface GC 363 S is exclusively for use with the GC 363 SF combined detector. The interface permits several combined detectors to be switched in series for FR sliding doors with large opening widths.
DescriptionGC 363 R / SF
Variant GC363 R GC363 SF Black 151237 151239 According to RAL 151238 151240
5
Description GC 363 R / SF
1 Cover 2 GC363 S interface (optional
accessory for GC363 SF) 3 Setting button (grey) 4 Button for setting the angle of
the AIR curtain (red) 5 AIR lens (transmitter)
6 AIR lens (receiver) 7 Radar antenna (wide eld) 8 Radar antenna (narrow eld) 9 Width adjustment of the AIR
curtain 10 LCD 11 Main connector
6
2.1 Supplied by GEZE
DescriptionGC 363 R / SF
7
Work to be done before installation GC 363 R / SF
3 Work to be done before installation
3.1 Installing the drive
X
Make sure that the drive cover is earthed.
8
3.2 Protection sensor
One combined detector per passage direction is installed on automatic sliding doors. The protection sensor GC 339 may be required in addition for larger opening widths.
X
See installation instructions GC 339.
For escape and rescue routes:
à use protective door leaf if necessary. Heed standards.
GC 339
Work to be done before installationGC 363 R / SF
GC 363 R
GC 363 R
GC 339
GC 363 R
GC 363 SF
9
Installation GC 363 R / SF
4 Installation
4.1 Installation without accessories
X
Avoid extreme vibrations.
X
Do not cover the sensor.
X
Keep away from uorescent lamps.
X
Keep away from moving objects.
X
Avoid highly reective objects in the infrared range.
1
DIN 7981 8 × ½“
8 mm
2
max. 50 mm
GC 362
10
4.2 Installation with ceiling installation set
1
68 × 293 mm
2
InstallationGC 363 R / SF
3
DOOR SIDE
DOOR SIDE
11
Installation GC 363 R / SF
4
5
1
3
4
click
1
click
12
6
click
4.3 Installation with mounting bracket
1
2
InstallationGC 363 R / SF
DIN 7981 8 × ½“
1
3
13
Installation GC 363 R / SF
4.4 Installation with weather canopy
2
3
1
2
4
14
4.5 Cabling
X
Heed wiring diagrams for the sliding door drives.
InstallationGC 363 R / SF
GC363 R
GC363 SF
GC 363 SF +
1
1
3
The optional interface GC 363 S is exclusively for use with the GC 363 SF combined detector. The interface permits several combined detectors to be switched in series for FR sliding doors with large opening widths.
15
Commissioning GC 363 R / SF
0
5 Commissioning
5.1 Radar detector
X
Set the detection eld and sensitivity of the radar movement detector as per AutSchR:
à Scanned eld = opening width x 1.5 m à Movement speed from 10 cm/s must be detected à The whole door width must be covered for escape and rescue
route doors
2.2 m
15°
1
2
3
30°
45°
0
1
2
2
1
15°…45°
0
1
-15°
2
3
3
4m x 2m
2.2 m
0
1
2
3
3
0
1
2
3
2
1
0
1
2
3
2.2 m
0
1
2
–15°…15°
2m x 2,5m
2.5 m
1
2
3
+15°
1
2.2 m
1
0
3
2
3
2
16
Replacing radar antennas (narrow and wide)
1
3
4
CommissioningGC 363 R / SF
6
5
17
Commissioning GC 363 R / SF
5.2 Protection area
The position of the IR curtain in relation to the door can be checked using an infrared detector.
X
Activate 4 visible spots.*
X
Adapt the angle of the AIR curtain.
2x
* Visibility depends on the environmental conditions.
Yellow LED is ashing on infrared detec-
: Alignment
tor correct.
max. 9 cm
max. 20 cm
18
X
Testing the emission area.
à The whole width of the door must be covered. à Test the width of the required area using a piece of paper (DIN A4), since
the infrared detector scans the whole emission area.
Standard-conform sensor setting according to DIN 18650 / EN 16005
Installation height Scanned width DIN18650 / EN 16005
CommissioningGC 363 R / SF
2.00 m
2.20 m
2.50 m
3.00 m
3.50 m
5.3 Settings
X
Congure the sensor using LCD or remote control (see chapters 6 and 7).
2.00 m
2.20 m
2.50 m
2.50 m / 3.00 m
2.50 m / 3.00 m
19
Conguration possibilities GC 363 R / SF
Weiter
Zurück
Voreinst.
5.4 Teaching
X
Before starting teaching, move out of the infrared eld.
X
Before leaving the installation, test the correct sensor installation.
Teaching 2 sec.
Teaching with door movement
+
4 sec.
6 Conguration possibilities
6.1 Using the LCD menu
6.1.1 Display during normal function
Opening impulse Protection Image shown negative
= active exit
6.1.2 Menu navigation
Passwort
X X X
X
X
Enter password, if set
English
Deutsch
Français
Set contrast
Zurück
0
Weiter
20
6.1.3 Changing ZIP code
Voreinst.
Voreinst.
2
Voreinst.
6.1.4 Changing and storing values
SettingsGC 363 R / SF
AIR:Filter
<2.8m 2
AIR:Filter
>2.8m 4
AIR:Filter
6.1.5 Checking values using the remote control
LCD
2
+
uni
7 Settings
7.1 Default settings
X
Choose the following default settings or congure the settings yourself (chapter 6 on page 20).
STANDARD: Standard inside and outside installations
DIFFICULT ENVIRONMENTS: Dicult installations due to environment or weather
SHOPPING STREET: Installations in narrow pedestrian areas
>2.8m 4
Standard
Kritische Bed.
Einkaufsstr.
21
Settings GC 363 R / SF
> large
To ensure compliance with EN 16005 and
DIN 18650, the values 6 and 7 must be
selected for an installation height of 2.8
m or more
*)
>
Opener
Frequency
Opener
Current
Inside Outside
Use dierent frequencies for sensors which have been installed next
to or above one another.
GC 363 SF only: Do not use automatic direction detection mode (parameter RAD:Direction 5 to 7) if the sensor
is used in an emergency exit.
X
22
0 1 2 3 4 5 6 7 8 9
Back / Continue
BASIC menu
Factory settings2 Increased immunity lter + 1 curtain3 Increased immunity lter + diversion = movement and presence
1
3
street
Shopping
2
cond.
Dicult
1
Standard
Comfort
default settings
> >
Not permitted for FR doors!
> >
small >
RAD: Size
Closer
Opener
Opener
Closer
RAD: Output
Closer
Opener
Closer
Opener
< 2.8 m > 2.8 m
not compliant with
higher highest normal high
DIN18650 / EN16005
low normal high
AIR: Filter
B
A
AIR: Frequency
Back / Continue
*) Standard setting GC 363 SF
for persons with restricted mobility
+
9
EM:
**
EM
**
uni
**
bi
uni
direction detection away
AWAY:
auto
auto
auto
AWAY
adaptation to eld size in small
shops (not suitable for FR doors)
from the sensor
auto:
Frequency
Current
Closer
***)
Opener
Opener
Closer
Opening output is active in the case of: (0) Movement detection
(1) Movement or presence detection
(2) Movement and presence detection
SettingsGC 363 R / SF
Partial reset
Full reset
(outputs are not reset)
EM
0 1 2 3 4 5 6 7 8 9
ADVANCED menu
Back / Continue
low > > > > > > high
RAD: Filter
uni
uni
*
bi
**
Radar o
RAD: Direction
* The bi-setting is more sensitive to the inuences of the weather.
** The setting is not permitted if the sensor is used in emergency exits.
0.5 sec. 1 sec. 2 sec. 3 sec. 4 sec. 5 sec. 6 sec. 7 sec. 8 sec. 9 sec.
RAD: Holding time
AIR: Width
In addition, always use a screwdriver to set the arrows for eld width on the detector.
1 min. 2 min. 5 min. 10 min. 20 min. 60 min. endless
Opener
Service mode = no scanning of presence for 15 minutes (during maintenance).
This value does not permit conformity of the door system with EN 16005 and DIN 18650.
30 sec.
1 2
mode
Service
Movem. 15 sec.
AIR: Quantity
AIR: Max. time
Opener
Closer
Opener
Closer
Opener
Minimum value for DIN 18650: 1 min.
Minimum value for EN 16005: 30 sec.
AIR: Output
Movem. (1)
and pres. (2)
pres. (2)
Movem. (1) or
Movem. (1)
Diversion
Reset to factory settings.
Factory settings
Back / Continue
***) Standard setting GC 363 SF
23
Settings GC 363 R / SF
time
st
Power supply at the plug
Time since voltage switched on for
1
Deletes all stored errors
Password for LED and remote control
(0000 = no password)
Language of the LCD menu
Enter code for administration mode
POWER SUPPLY
OPERATING TIME
DELETE ERROR
PASSWORD
LANGUAGE
ADMIN
24
All parameter values in zipped format (code)
In the event of any faults, inform the service employee responsible of this ZIP code.
Individual ID number
DIAGNOSIS menu
ZIP
ID #
The last 10 errors and day display
Displays the spots which trigger scanning
Error
AIR: Spot view
Signal amplitude at curtain 1
AIR: V1 ENERG
Signal amplitude at curtain 2
AIR: V2 ENERG
8 Last installation steps
X
Before leaving the installation, check the sensor for correct function.
1
Last installation stepsGC 363 R / SF
25
Further installation situations GC 363 R / SF
9 Further installation situations
9.1 Single leaf installation
Installation height Distance between
detector and HSK
2000 0 1150 2000 2200 100 1350 2200 2500 250 1650 2500 3000 500 1900 2500 / 3000 3500 750 2150 2500 / 3000
* When only one combined detector is used. Otherwise a GC 339 is required for
further protection.
Max. leaf width* Scanned width
DIN18650/EN 16005
1
2
1 Distance 2 HSK 3 Installation height 4 Protection; 2 m height accord-
ing to DIN 18650 / EN 16005 5 Leaf width 6 Scanned width
3
26
4
5
6
9.2 Lintel installation
According to DIN 18650/EN 16005, the distance between the inner light curtains must not exceed 200 mm.
Example conguration:
à Light curtain (right-hand
side) set to –5°
à Combined detector near the
door leaf at a distance of 50 mm to the leaf
à Protection under the sot
150 mm
In the case of other dimensions, please contact the sales department rst.
Further installation situationsGC 363 R / SF
Installation height a
(in mm)
2000 325 2200 342 2500 369 3000 412 3500 456
Max. sot depth b
(in mm)


27
Maintenance GC 363 R / SF
10 Maintenance
X
The visual parts must be cleaned at least once a year.
X
Do not use aggressive cleaning agents or chemicals.
11 Error messages and troubleshooting
LCD
Eect Cause Elimination
display E1 The ORANGE
LED ashes 1 x
E2 The ORANGE
LED ashes 2 x
E4 The ORANGE
LED ashes 4 x
E5 The ORANGE
LED ashes 5 x
E6 GC 363 SF only:
The ORANGE LED ashes 6 x
E7 GC 363 SF only:
The ORANGE LED ashes 7 x
E8 The ORANGE
LED ashes 8 x
E9 The ORANGE
LED ashes 9 x
The sensor has de­tected an internal error.
The power supply is too low or too high.
The sensor is receiving too little AIR energy.
The sensor is receiving too much AIR energy.
External elements are interfering with the sensor.
The radar output is defective.
Interference of the internal radar test.
The AIR energy transmitter is defective.
The internal radar reference is incor­rect.
X
Replace the sensor.
X
Check the power supply (in the LCD diagnosis menu).
X
Check the wiring.
X
Reduce the AIR angle.
X
Increase the AIR immunity lter (values > 2.8 m).
X
Disable 1 curtain.
X
Slightly increase the AIR angle.
X
Check for interfering ele­ments and eliminate if neces­sary (e.g. lamps or earthing of the drive housing).
X
Reduce the AIR immunity lter to 1, 2 or 3.
X
Replace the sensor.
X
Change the radar angle.
X
Change the radar antenna.
X
Replace the sensor if the ORANGE LED continues to ash.
X
Replace the sensor.
X
Replace the sensor.
28
Error messages and troubleshootingGC 363 R / SF
LCD
Eect Cause Elimination
display – The ORANGE
LED is on
The RED LED
ashes quickly after teaching with door move­ment
The RED LED
lights up sporad­ically
The GREEN LED
lights up sporad­ically
The sensor has a memory problem.
The sensor senses the door during teaching with door movement.
The sensor is vibrating.
The sensor senses the door.
Elements in the environment are interfering with the sensor.
Rain or falling leaves are interfer­ing with the sensor.
Phantom open­ing through door movement.
The sensor is vibrating.
The sensor senses the door or other moving objects.
X
Switch the power supply o and on.
X
Replace the sensor if the ORANGE LED lights up again.
X
Remove AIR curtains from the door.
X
Install the sensor as close as possible to the door. Use installation accessories if necessary.
X
Start teaching with door movement. Move out of the scanning area for this.
X
Check whether the sensor has been xed in place correctly.
X
Check the position of cable and cover.
X
Start teaching with door movement and change the AIR angle.
X
Increase AIR immunity lter to 3.
X
Select default setting 2 and 3.
X
Select default setting 2 and 3.
X
Increase the radar immunity lter.
X
Change radar angle.
X
Check whether the sensor and door prole have been xed in place correctly.
X
Check the position of cable and cover.
X
Remove objects if possible.
X
Change radar eld size or angle.
29
Error messages and troubleshooting GC 363 R / SF
LCD
Eect Cause Elimination
display – The LED and the
LCD display are o
The responses
of the door and the LED do not correlate
The LCD display
or remote control are not responding.
The sensor is protected by a password.
X
Check the wiring.
X
Check initial conguration.
X
Check the wiring.
X
Enter the access code.
Forgotten the access code?
X
Switch the power supply on and o during the 1st minute after switch-on to unlock the sensor.
30
12 Technical data
Power supply: 12V to 24V, AC ±10%; 12V to 30V, DC ±10%
Power consump­tion:
Installation height: 2m to 3.5m
Temperature range:
Protection rating: IP54 according to EN 60529
Applicable direc­tives:
Scanning mode: Movement Presence
< 2.5W
–25°C to +55°C, 0 to 95% relative humidity, non-condensing
R&TTE 1999/5/EC, MD 2006/42/EC, RoHS 2 2011/65/EU, LVD 2006/95/EC
Technical dataGC 363 R / SF
Min. scanning speed: 5 cm/s Typical response time:
Technology: Microwave Doppler radar
Output (GC363 R):
Output (GC363 SF):
Transmission frequency:
24.150GHz Transmission power: < 20dBm EIRP Density of transmission power: < 5mW/cm
Semiconductor relay (poten­tial-free, polarity-free) Max. switching current: 100mA Max. switching voltage: 42V, AC/DC
Semiconductor relay (poten­tial-free, polarity-free) Max. switching current: 100 mA Max. switching voltage: 42V, AC/DC
Frequency output: Pulsating signal (f = 100Hz ± 10%)
Current source output: dc insulated current source active Freeswing voltage: 6.5V Output voltage at 10 mA: 3V min. Typical load: up to 3 opto-couplers in series Movement detection: Current source inactive Idling voltage: < 500mV
2
< 200ms (max. 500ms)
Active infrared control with back­ground evaluation Spot: 5cm x 5cm (typ.) Number of light beams: max. 24 per curtain Number of curtains: 2
Semiconductor relay (standard) (potential-free, polarity-free) Max. switching current: 100mA Max. switching voltage: 42V, AC/DC Holding time: 0.3 to 1s
Semiconductor relay (standard) (potential-free, polarity-free) Max. switching current: 100 mA Max. switching voltage: 42V, AC/DC Holding time: 0.3 to 1s
31
Technical data GC 363 R / SF
Movement Presence
Test input Signal voltage:
Interference inu­ences
Conformity to standard (GC363 R)
Conformity to standard (GC363 SF)
Type-tested by the German Associa­tion for Technical Inspection(TÜV)
< 70dB
EN 12978 EN ISO 13849-1: 2008 PL «d» CAT.2 EN 16005: 2012 Chapter 4.6.8 DIN 18650-1: 2010 Chapter 5.7.4; AutSchR BS 7036-1: 1996 Chapter 7.3.2 (only applicable for frequency and current source output)
EC certificate of conformity number 44 205 13089602
Low: < 1V, High: > 10V (max. 30V) Response time to test query: <5ms (typ.)
EN 12978 EN ISO 13849-1: 2008 PL «c» CAT.2 (providing the door drive tests the sensor at least once per door cycle) IEC 61496-1:2012 ESPE Type 2 EN 16005: 2012 Chapter 4.6.8 DIN 18650-1: 2010 Chapter 5.7.4 BS 7036-1: 1996 Chapter 8.1
EN 12978 EN ISO 13849-1: 2008 PL «c» CAT.2 (providing the door drive tests the sensor at least once per door cycle) IEC 61496-1:2012 ESPE Type 2 EN 16005: 2012 Chapter 4.6.8 DIN 18650-1: 2010 Chapter 5.7.4 BS 7036-1: 1996 Chapter 8.1
Only for EU countries: In compliance with the European Directive 2012/19/ EU concerning waste electrical and electronic equipment (WEEE)
32
13 Accessories / Spare parts
Accessories / Spare partsGC 363 R / SF
Material no.
Ceiling bracket
Ceiling installation kit
Weather canopy
GC363 S interface
Curved adaptor
151256
151253 (black) 151254 (white)
158250
151361 (for GC 363 SF only)
151255
Remote control
Infrared detector
100061
112321
33
GC 363 R / SF
34
GC 363 R / SF
35
Germany
GEZE Sonderkonstruktionen GmbH Planken 1 97944 Boxberg-Schweigern Tel. +49 (0) 7930 9294 0 Fax +49 (0) 7930 9294 10 E-Mail: sk.de@geze.com
GEZE GmbH Niederlassung Süd-West Tel. +49 (0) 7152 203 594 E-Mail: leonberg.de@geze.com
GEZE GmbH Niederlassung Süd-Ost Tel. +49 (0) 7152 203 6440 E-Mail: muenchen.de@geze.com
GEZE GmbH Niederlassung Ost Tel. +49 (0) 7152 203 6840 E-Mail: berlin.de@geze.com
GEZE GmbH Niederlassung Mitte/Luxemburg Tel. +49 (0) 7152 203 6888 E-Mail: frankfurt.de@geze.com
GEZE GmbH Niederlassung West Tel. +49 (0) 7152 203 6770 E-Mail: duesseldorf.de@geze.com
GEZE GmbH Niederlassung Nord Tel. +49 (0) 7152 203 6600 E-Mail: hamburg.de@geze.com
GEZE Service GmbH Tel. +49 (0) 1802 923392 E-Mail: service-info.de@geze.com
Austria
GEZE Austria E-Mail: austria.at@geze.com www.geze.at
Baltic States
GEZE GmbH Baltic States oce E-Mail: oce-latvia@geze.com www.geze.com
Benelux
GEZE Benelux B.V. E-Mail: benelux.nl@geze.com www.geze.be www.geze.nl
Bulgaria
GEZE Bulgaria - Trade E-Mail: oce-bulgaria@geze.com www.geze.bg
China
GEZE Industries (Tianjin) Co., Ltd. E-Mail: chinasales@geze.com.cn www.geze.com.cn
GEZE Industries (Tianjin) Co., Ltd. Branch Oce Shanghai E-Mail: chinasales@geze.com.cn www.geze.com.cn
GEZE Industries (Tianjin) Co., Ltd. Branch Oce Guangzhou E-Mail: chinasales@geze.com.cn www.geze.com.cn
GEZE Industries (Tianjin) Co., Ltd. Branch Oce Beijing E-Mail: chinasales@geze.com.cn www.geze.com.cn
France
GEZE France S.A.R.L. E-Mail: france.fr@geze.com www.geze.fr
Hungary
GEZE Hungary Kft. E-Mail: oce-hungary@geze.com www.geze.hu
Iberia
GEZE Iberia S.R.L. E-Mail: info@geze.es www.geze.es
India
GEZE India Private Ltd. E-Mail: oce-india@geze.com www.geze.in
Italy
GEZE Italia S.r.l E-Mail: italia.it@geze.com www.geze.it
GEZE Engineering Roma S.r.l E-Mail: roma@geze.biz www.geze.it
Poland
GEZE Polska Sp.z o.o. E-Mail: geze.pl@geze.com www.geze.pl
Romania
GEZE Romania S.R.L. E-Mail: oce-romania@geze.com www.geze.ro
Russia
OOO GEZE RUS E-Mail: oce-russia@geze.com www.geze.ru
Scandinavia – Sweden
GEZE Scandinavia AB E-Mail: sverige.se@geze.com www.geze.se
Scandinavia – Norway
GEZE Scandinavia AB avd. Norge E-Mail: norge.se@geze.com www.geze.no
Scandinavia – Denmark
GEZE Danmark E-Mail: danmark.se@geze.com www.geze.dk
Singapore
GEZE (Asia Pacic) Pte, Ltd. E-Mail: gezesea@geze.com.sg www.geze.com
South Africa
GEZE Distributors (Pty) Ltd. E-Mail: info@gezesa.co.za www.geze.co.za
Switzerland
GEZE Schweiz AG E-Mail: schweiz.ch@geze.com www.geze.ch
Turk ey
GEZE Kapı ve Pencere Sistemleri E-Mail: oce-turkey@geze.com www.geze.com
Ukraine
LLC GEZE Ukraine E-Mail: oce-ukraine@geze.com www.geze.ua
United Arab Emirates/GCC
GEZE Middle East E-Mail: gezeme@geze.com www.geze.ae
United Kingdom
GEZE UK Ltd. E-Mail: info.uk@geze.com www.geze.com
GEZE GmbH
Reinhold-Vöster-Straße 21–29 71229 Leonberg Germany
Tel.: 0049 7152 203 0 Fax: 0049 7152 203 310
www.geze.com
Loading...