11 Error messages and troubleshooting ........................................... 28
12 Technical data ....................................................................................... 31
13 Accessories / Spare parts .................................................................. 33
Symbols and illustrations
Warning notices
Warning notices are used in these instructions to warn you of property
damage and personal injury.
X
Always read and observe these warning notices.
X
Observe all the measures that are marked with the warning symbol and
warning word .
Abbreviations
FREscape and rescue routes
IRInfrared
AIRActive infrared control
RADRadar
LCDLiquid Crystal Display
HSKMain closing edge
NSKSecondary closing edge
SafetyGC 363 R / SF
Product liability
In accordance with the liability of the manufacturer for his products as
dened in the German "Product Liability Act", the information contained
in this brochure (product information and proper use, misuse, product
performance, product maintenance, obligations to provide information and
instructions) is to be observed. Failure to comply releases the manufacturer
from his statutory liability.
1 Safety
1.1 Intended use
The combined sensor GC 363 may only be used to actuate and safeguard
automatic sliding doors and circular sliding doors with GEZE drives. The
minimum object size corresponds to the reference object CA according to
DIN 18650 or 16005 both upright and lying down. The sensor can be used to
secure automatic sliding doors against impact and trapping of the human
body.
3
SafetyGC 363 R / SF
GC363 R
GC363 SF
(in the direction of
1.2 Safety notices
à The mandatory installation, maintenance and repair work must be per-
formed by properly trained personnel authorised by GEZE. Any attempts
at repairs by unauthorised personnel cancel the factory guarantee.
à The device may only be operated with safety extra-low voltage (SELV)
with electrically protective separation.
à The country-specic laws and regulations are to be observed during
safety-related tests.
à Make sure that the door control cover is tted correctly and earthed.à If unauthorised changes are made to the system, GEZE cannot be held
liable in any way whatsoever for any resulting damage, and the approval
for use in escape and rescue routes ceases.
à GEZE makes no guarantee for combinations with third-party products.à Only original GEZE parts may be used for repair and maintenance work.à Observe the latest versions of directives, standards and country-specic
regulations, in particular:
à ASR A1.7 "Doors and gates"à DIN 18650 "Building hardware – Automatic door systems"à DIN EN 16005 "Power operated pedestrian doorsets – Safety in use –
Requirements and test methods"
à Accident-prevention regulations, especially BGV A1 "General regula-
tions" and BGV A2 "Electrical systems and equipment".
à The risk assessment and installation of the sensor and the door system in
compliance with national and international regulations and door safety
standards are the responsibility of the door manufacturer.
à Any uses of the device other than those described in this manual do not
correspond to the approved purpose and cannot be guaranteed by the
manufacturer.
emergency exit)
4
1.3 Safety conscious working
à Secure workplace against unauthorised entry.à Watch swivelling range of long system parts.à Secure the cover/drive panels against falling.à Attach safety stickers to glass door leaves.à Danger of injury with opened drive. Hair, clothing, cables, etc. can be
drawn in by rotating parts.
à Danger of injury caused by unsecured crushing, impact, drawing-in or
shearing spots.
à Danger of injury due to broken glass.à Danger of injury due to sharp edges in the drive.à Danger of injury during installation through freely moving parts.
1.4 Environmentally conscious working
à When disposing of the door system, separate the dierent materials and
have them recycled.
2 Description
The combined detectors GC 363 R / SF have a radar eld for detecting
movement and an infrared eld for protection.
It is not possible for several systems to inuence each other and result in a
hazard. Unintentional stop signals are possible where detectors are mounted next to one another as their infrared measuring ranges overlap and each
sensor could activate the other. This inuence is kept to a minimum by
dierent frequency settings.
The optional interface GC 363 S is exclusively for use with the GC 363 SF
combined detector. The interface permits several combined detectors to be
switched in series for FR sliding doors with large opening widths.
DescriptionGC 363 R / SF
VariantGC363 RGC363 SF
Black151237151239
According to RAL151238151240
5
DescriptionGC 363 R / SF
1 Cover
2 GC363 S interface (optional
accessory for GC363 SF)
3 Setting button (grey)
4 Button for setting the angle of
the AIR curtain (red)
5 AIR lens (transmitter)
6 AIR lens (receiver)
7 Radar antenna (wide eld)
8 Radar antenna (narrow eld)
9 Width adjustment of the AIR
curtain
10 LCD
11 Main connector
6
2.1 Supplied by GEZE
DescriptionGC 363 R / SF
7
Work to be done before installationGC 363 R / SF
3 Work to be done before installation
3.1 Installing the drive
X
Make sure that the drive cover is earthed.
8
3.2 Protection sensor
One combined detector per passage direction is installed on automatic
sliding doors. The protection sensor GC 339 may be required in addition for
larger opening widths.
X
See installation instructions GC 339.
For escape and rescue routes:
à use protective door leaf if necessary. Heed standards.
GC 339
Work to be done before installationGC 363 R / SF
GC 363 R
GC 363 R
GC 339
GC 363 R
GC 363 SF
9
InstallationGC 363 R / SF
4 Installation
4.1 Installation without accessories
X
Avoid extreme vibrations.
X
Do not cover the sensor.
X
Keep away from uorescent lamps.
X
Keep away from moving objects.
X
Avoid highly reective objects in the infrared range.
1
DIN 7981 8 × ½“
8 mm
2
max. 50 mm
GC 362
10
4.2 Installation with ceiling installation set
1
68 × 293 mm
2
InstallationGC 363 R / SF
3
DOOR SIDE
DOOR SIDE
11
InstallationGC 363 R / SF
4
5
1
3
4
click
1
click
12
6
click
4.3 Installation with mounting bracket
1
2
InstallationGC 363 R / SF
DIN 7981 8 × ½“
1
3
13
InstallationGC 363 R / SF
4.4 Installation with weather canopy
2
3
1
2
4
14
4.5 Cabling
X
Heed wiring diagrams for the sliding door drives.
InstallationGC 363 R / SF
GC363 R
GC363 SF
GC 363 SF +
1
1
3
The optional interface GC 363 S is exclusively for use with the GC 363 SF
combined detector. The interface permits several combined detectors to
be switched in series for FR sliding doors with large opening widths.
15
CommissioningGC 363 R / SF
0
5 Commissioning
5.1 Radar detector
X
Set the detection eld and sensitivity of the radar movement detector as
per AutSchR:
à Scanned eld = opening width x 1.5 mà Movement speed from 10 cm/s must be detectedà The whole door width must be covered for escape and rescue
route doors
2.2 m
15°
1
2
3
30°
45°
0
1
2
2
1
15°…45°
0
1
-15°
2
3
3
4m x 2m
2.2 m
0
1
2
3
3
0
1
2
3
2
1
0
1
2
3
2.2 m
0°
0
1
2
–15°…15°
2m x 2,5m
2.5 m
1
2
3
+15°
1
2.2 m
1
0
3
2
3
2
16
Replacing radar antennas (narrow and wide)
1
3
4
CommissioningGC 363 R / SF
6
5
17
CommissioningGC 363 R / SF
5.2 Protection area
The position of the IR curtain in relation to the door can be checked using
an infrared detector.
X
Activate 4 visible
spots.*
X
Adapt the angle of the AIR
curtain.
2x
* Visibility depends on the environmental conditions.
Yellow LED is ashing
on infrared detec-
: Alignment
tor
correct.
max. 9 cm
max. 20 cm
18
X
Testing the emission
area.
à The whole width of the door must be covered.à Test the width of the required area using a piece of paper (DIN A4), since
the infrared detector scans the whole emission area.
Standard-conform sensor setting according to DIN 18650 / EN 16005
Installation heightScanned width DIN18650 / EN 16005
CommissioningGC 363 R / SF
2.00 m
2.20 m
2.50 m
3.00 m
3.50 m
5.3 Settings
X
Congure the sensor using LCD or remote control (see chapters 6 and 7).
2.00 m
2.20 m
2.50 m
2.50 m / 3.00 m
2.50 m / 3.00 m
19
Conguration possibilitiesGC 363 R / SF
Weiter
Zurück
Voreinst.
5.4 Teaching
X
Before starting teaching, move out of the infrared eld.
X
Before leaving the installation, test the correct sensor installation.
Teaching2 sec.
Teaching with door movement
+
4 sec.
6 Conguration possibilities
6.1 Using the LCD menu
6.1.1 Display during normal function
Opening impulse ProtectionImage shown negative
= active exit
6.1.2 Menu navigation
Passwort
X X X
X
X
Enter
password,
if set
English
Deutsch
Français
Set contrast
Zurück
0
Weiter
20
6.1.3 Changing ZIP code
Voreinst.
Voreinst.
2
Voreinst.
6.1.4 Changing and storing values
SettingsGC 363 R / SF
AIR:Filter
<2.8m 2
AIR:Filter
>2.8m 4
AIR:Filter
6.1.5 Checking values using the remote control
LCD
2
+
uni
7 Settings
7.1 Default settings
X
Choose the following default settings or congure the
settings yourself (chapter 6 on page 20).
STANDARD:
Standard inside and outside installations
DIFFICULT ENVIRONMENTS:
Dicult installations due to environment or weather
SHOPPING STREET:
Installations in narrow pedestrian areas
>2.8m 4
Standard
Kritische Bed.
Einkaufsstr.
21
SettingsGC 363 R / SF
>large
To ensure compliance with EN 16005 and
DIN 18650, the values 6 and 7 must be
selected for an installation height of 2.8
m or more
*)
>
Opener
Frequency
Opener
Current
InsideOutside
Use dierent frequencies for sensors which have been installed next
to or above one another.
GC 363 SF only: Do not use automatic direction detection mode (parameter RAD:Direction 5 to 7) if the sensor
is used in an emergency exit.
X
22
0123456789
Back / Continue
BASIC menu
Factory settings2 Increased immunity lter + 1 curtain3 Increased immunity lter + diversion = movement and presence
1
3
street
Shopping
2
cond.
Dicult
1
Standard
Comfort
default settings
>>
Not permitted for FR doors!
>>
small>
RAD: Size
Closer
Opener
Opener
Closer
RAD: Output
Closer
Opener
Closer
Opener
< 2.8 m> 2.8 m
not compliant with
higherhighestnormalhigh
DIN18650 / EN16005
lownormalhigh
AIR: Filter
B
A
AIR: Frequency
Back / Continue
*) Standard setting GC 363 SF
for persons with restricted mobility
+
9
EM:
**
EM
**
uni
**
bi
uni
direction detection away
AWAY:
auto
auto
auto
AWAY
adaptation to eld size in small
shops (not suitable for FR doors)
from the sensor
auto:
Frequency
Current
Closer
***)
Opener
Opener
Closer
Opening output is active in the case of: (0) Movement detection
(1) Movement or presence detection
(2) Movement and presence detection
SettingsGC 363 R / SF
Partial reset
Full reset
(outputs are not reset)
EM
0123456789
ADVANCED menu
Back / Continue
low>>>>>>high
RAD: Filter
uni
uni
*
bi
**
Radar o
RAD: Direction
* The bi-setting is more sensitive to the inuences of the weather.
** The setting is not permitted if the sensor is used in emergency exits.
0.5 sec.1 sec.2 sec.3 sec. 4 sec.5 sec.6 sec.7 sec.8 sec.9 sec.
RAD: Holding time
AIR: Width
In addition, always use a screwdriver to set the arrows for eld width on the detector.
1 min.2 min.5 min. 10 min. 20 min.60 min.endless
Opener
Service mode = no scanning of presence for 15 minutes (during maintenance).
This value does not permit conformity of the door system with EN 16005 and DIN 18650.
30 sec.
12
mode
Service
Movem.15 sec.
AIR: Quantity
AIR: Max. time
Opener
Closer
Opener
Closer
Opener
Minimum value for DIN 18650: 1 min.
Minimum value for EN 16005: 30 sec.
AIR: Output
Movem. (1)
and pres. (2)
pres. (2)
Movem. (1) or
Movem. (1)
Diversion
Reset to factory settings.
Factory settings
Back / Continue
***) Standard setting GC 363 SF
23
SettingsGC 363 R / SF
time
st
Power supply at the plug
Time since voltage switched on for
1
Deletes all stored errors
Password for LED and remote control
(0000 = no password)
Language of the LCD menu
Enter code for administration mode
POWER SUPPLY
OPERATING TIME
DELETE ERROR
PASSWORD
LANGUAGE
ADMIN
24
All parameter values in zipped format (code)
In the event of any faults, inform the service employee responsible of this ZIP code.
Individual ID number
DIAGNOSIS menu
ZIP
ID #
The last 10 errors and day display
Displays the spots which trigger scanning
Error
AIR: Spot view
Signal amplitude at curtain 1
AIR: V1 ENERG
Signal amplitude at curtain 2
AIR: V2 ENERG
8 Last installation steps
X
Before leaving the installation, check the sensor for correct function.
Frequency output:
Pulsating signal (f = 100Hz ± 10%)
Current source output:
dc insulated current source active
Freeswing voltage: 6.5V
Output voltage at 10 mA: 3V min.
Typical load: up to 3 opto-couplers in series
Movement detection: Current source inactive
Idling voltage: < 500mV
2
< 200ms (max. 500ms)
Active infrared control with background evaluation
Spot: 5cm x 5cm (typ.)
Number of light beams:
max. 24 per curtain
Number of curtains: 2
Semiconductor relay (standard)
(potential-free, polarity-free)
Max. switching current: 100 mA
Max. switching voltage:
42V, AC/DC
Holding time: 0.3 to 1s
31
Technical dataGC 363 R / SF
MovementPresence
Test inputSignal voltage:
Interference inuences
Conformity to
standard (GC363
R)
Conformity to
standard (GC363
SF)
Type-tested by the
German Association for Technical
Inspection(TÜV)
< 70dB
EN 12978
EN ISO 13849-1: 2008 PL «d» CAT.2
EN 16005: 2012 Chapter 4.6.8
DIN 18650-1: 2010 Chapter 5.7.4;
AutSchR
BS 7036-1: 1996 Chapter 7.3.2
(only applicable for frequency and
current source output)
EC certificate of conformity number 44 205 13089602
Low: < 1V, High: > 10V (max. 30V)
Response time to test query: <5ms
(typ.)
EN 12978
EN ISO 13849-1: 2008 PL «c» CAT.2
(providing the door drive tests the
sensor at least once per door cycle)
IEC 61496-1:2012 ESPE Type 2
EN 16005: 2012 Chapter 4.6.8
DIN 18650-1: 2010 Chapter 5.7.4
BS 7036-1: 1996 Chapter 8.1
EN 12978
EN ISO 13849-1: 2008 PL «c» CAT.2
(providing the door drive tests the
sensor at least once per door cycle)
IEC 61496-1:2012 ESPE Type 2
EN 16005: 2012 Chapter 4.6.8
DIN 18650-1: 2010 Chapter 5.7.4
BS 7036-1: 1996 Chapter 8.1
Only for EU countries: In compliance with the European Directive 2012/19/