GE
Fiber Optic
Security
Overview
The S751DA and S7751DA fiber links provide two-way
transmission of audio, multiprotocol data, and contact
closure over one or two single mode or multimode fibers.
Digital Processing
Digital processing of the audio signal along with an audio signalto-noise ratio >90dB allows the audio output to drive balanced
or unbalanced loads and maintain constant audio levels.
Data Translation
The data functions include the unique data translation feature,
which allows one data format to be input and a different data
format to be output. Data formats are selected during installation
and can be easily changed in the field via rotary switch.
Superior Diagnostics
The SMARTS™ diagnostic technology provides an extensive
set of diagnostic tools including an audio test generator
to verify audio channel operation. LEDs provide a visual
indication of the operating status of the audio, data, and
contact channels as well as the optical signal strength.
Audio and Data with
Contact Closure
Standard Features
• Two-way audio, data and contact closure
transmission over one or two single mode or
multimode fibers
• 24-bit audio processing
• Unique data translation function
• Local or remote user-selectable data format
• Supports multiprotocol data formats
• Relay/contact closure - 1 duplex channel
• Built-in audio test generator
• Diagnostic LEDs
Two-Way Audio,
Multiprotocol
Data and
Contact Closure
S751DA and S7751DA
GE
GE
Security
Security
U.S.
T (561) 998-6100
T 888-GE-SECURITY
888-(437-3287)
F 561 998 6224
Canada
T 519 376 2430
F 519 376 7258
Asia
T 852-2907-8108
F 852-2142-5063
Australia
T 61-3-9239-1200
F 61-3-9239-1299
Europe
T
32-2-719-9847
F
32-2-719-9846
Latin America
T 305-593-4301
F 305-593-4300
www.gesecurity.com
© 2005 General Electric Company
All Rights Reserved
Related Diagram
Audio In/Out
Data
In/Out
Contact
In/Out
Transmitter
Optical Fiber
Receiver
Audio In/Out
Data
In/Out
Contact
In/Out
Specifications
Audio S751DA (Multimode) S7751DA (Single Mode)
Channels 1 duplex
Input Signal 17.4 V pk - pk, +18 dBu max.
Input Impedance
Bandwidth
Audio Sampling Rate
Signal-to-Noise Ratio
Total Harmonic Distortion
Data
Channels 1 duplex
Formats RS-232 (3-wire/5-wire), TTL, RS-422, RS-485 (2-wire/4-wire),
Baud Rate
Bit Error Rate
Relay/Contact Closure
Relay Contact Rating 1 A at 30 VDC
Optical
Mode Multimode Single Mode
Optical Budget 13 dB 18 dB
Emitter
Operating Distance
Wavelength
Gain Control
Electrical
Input Power 13.5 VDC regulated
Current Requirement 500 mA
Power Consumption 6.75 W
Power Factor 4
Protection Solid-state short circuit protection
Environmental
Operating Temperature -40 to 167 °F (-40 to 75 °C)
Maximum Humidity 95% relative, noncondensing
Mechanical
Dimensions, Rack Units 1 slot (1.0”)
Weight Standalone 0.7 lbs (0.32 kg)
Construction Aluminum
∗
∗∗
250 kbps to 512 kbps (depending on data format)
850 nm and/or 1300 nm 1310 nm and/or 1550 nm
600 ohms or 100k ohms
20 Hz to 20 kHz
52 kHz
>90 dB
<0.006%
Manchester, Biphase, SensorNet
<1.0E-9
1 duplex channel
Laser
11 mi (18 km) 37 mi (60 km)
(depending on model)
(depending on model)
Optical Automatic Gain Control (OAGC)
Ordering Information
Use the Configurator below to select the options available for this product.
S751DA
Product Type
TRTransmitter
Receiver
∗ Optical Budget based on 62.5 μm fiber, for 50/125 μm fiber subtract 3 dB.
∗∗ Operating distance is approximate and assumes best fiber. It will be affected by the type and number of splices in the fiber. Refer to update No. TB00-005, which can be found at www.gesecurity.com
As a company of innovation, GE Security reserves the right to change product specifications without notice. For the latest product specifications, visit GESecurity online at www.GESecurity.com or contact your GE Security sales representative.
S751DA-2006-09-2
- RST
No. of Fibers
1
Fiber
2
Fibers
imagination at work
imagination at work
Optical Wavelength
L
Add here only if ordering
High Order Wavelength
(2 Fiber units)
S7751DA
Receiver
Product TypeConnector Type
TFC
Transmitter FC Type
RST
Receiver ST Type
- R
No. of Fibers
12Fiber
Fibers
Optical Wavelength
Add here only if ordering
L
High Order Wavelength
(2 Fiber units)