GE Security 6197-N, 6198-N Specsheet

S E N T R O L
P R O D U C T I N F O R M A T I O N B U L L E T I N
6190 SERIES PASSIVE
INFRARED
Intrinsically Safe PIR System
Model number: 6197 6198
Model 6198 does not include barrier box
• The 6197 is UL and FM-approved for use in:
Class I, Division 1, Groups A,B,C,D; Class II, Division 1, Groups E,F,G; Class III, Division 1, hazardous
locations
Division 2, Groups A,B,C,D non-incendive applications
• Cast metal PIR, both water resistant and dust proof
• Advanced signal processing for superior intruder detection
• Includes three coverage patterns in the box
Sentrol’s 6197 Intrinsically Safe PIR system consists of two units: PIR and Barrier Box. The PIR is installed in the hazardous area while the Barrier Box is installed in the nonhazardous area. Sentrol’s 6198 Non- Incendive PIR consists of an encapsulated, self­contained PIR (without barrier box) for use in non­incendive applications.
Both the 6197 and 6198 utilize a dual pyroelectric sensor with jumper selectable one- or two-zone detection. These also feature a sequence processor that combines bi-directional pulse counting and Motion Verification, the most sophisticated signal processing available. An opaque, high resolution Fresnel lens focuses the infrared energy on the pyroelectric sensor while blocking stray or reflected light. The unit includes three lenses: standard, vertical barrier, and long range. The PIR is housed in a cast metal housing designed to mount flat on a wall. The case, as well as the mounting screws are gasketed for water resistant rating.
The 6197 utilizes Factory Mutual and UL Listed barriers provided in the Barrier Box that limit voltage and current on the PIR wiring to intrinsically safe levels. The switching module inside the Barrier Box provides protected relay contacts for alarm and tamper loops for connection to the alarm panel. The Barrier Box includes a NEMA-4 rated steel box with a lid.
continued
Sentrol 6190 Series Intrinsically Safe PIR System and Non-Incendive PIR
Specifications:
Electrical 6197
Voltage ..................................................................... 9 to 16 V DC
Current .......................................................................50 mA max.
Max. loop rating ......................................... 16 V DC, 50 mA max.
Alarm output ................ Fail safe contacts w/ 10 Ohms in series,
Form C, SPDT
Alarm duration ...................................................... 2 to 5 seconds
Housing tamper rating ............................... 16 V DC, 50 mA max.
Housing loop ................ Fail safe contacts w/ 10 Ohms in series,
Form A, Normally closed (SPST)
6198
Voltage ..................................................................... 7 to 16 V DC
Current .................................................8 mA typical, 10 mA max.
Max. loop rating ......................................... 16 V DC, 50 mA max.
Alarm output ................. Fail safe contacts w/10 Ohms in series,
Form A, SPST
Alarm duration ...................................................... 2 to 5 seconds
Cover Tamper Contacts .................................... Normally closed,
rating: 50 mA, 12 V DC
Standard Wide Angle
Top View
45'
13.7m
30'
9.1m
20'
6.1m
10'
3.0m
0
10'
20'
0
3.0m
6.1m
30'
9.1m
13.7m
Side View
7'
2.13m
0
45'
30° 15°
4°
Floor Line
Dimensions
Top View
Top View
Environmental: PIR
Operating temperature ............. -40°F to 120°F (-40°C to +50°C)
Dust proof, water resistant
RF Immunity ........... greater than10 V meter from 1 to 1000MHz
Static/lightning immunity ................. 2.5 kV, 2 joules max. energy
impulse, 1 msec rise / 50 msec decay
Environmental: Barrier Box (6197 only)
Operating temperature ............... -4°F to 140°F (-20°C to +60°C)
Dust proof, water proof if sealed fittings used
Features
Operating modes ........................... 1-zone, 2-zone, or test mode
Range
Standard Wide Angle ................................. 45' (13.7 m) x 90°
Long Range .................................................. 70' (21.3 m) x 6°
Vertical Barrier .............................................. 40' (12.2 m) x 6°
Mounting .................................................. Wall only/conduit entry
LED indicator ............................ Walktest, or disable with jumper
Dimensions PIR ..............................................5.12" (13.03 cm) H
5.12" (13.03 cm) W
3.25" (8.25 cm) D
Dimensions Barrier Box .................................. 9.50" (24.13 cm) H
7.40" (18.80 cm) W
Long Range
Top View
0'
7'
2.1m
6°
7.6'
2.3m
4.00" (10.16 cm) D
Side View
9'
2.7m
Vertical Barrier
7'
2.1m
0.9m6'1.8m
3'
Side View
19'
5.8m
29'
8.8m
34'
10.4m
Top View
0'
6°
70'
21.3m
40'
12.2m
Side View
Front View
Flat Wall Corner Top view (max. adjusting angle 22.5°)
°
Optional swivel mount bracket assembly, part No. 6083-N
Ordering Information
Model Loop Electrical Approvals Listing
Number Type Configuration
6197 Closed, Open SPDT (N.C. and N.O.) Class I, Division 1, Groups A,B,C,D; Class II UL, FM
Div. 1, Groups E,F,G; Class III, Div. 1
6198 Closed SPST (N.C.) Class I, Division 2 Groups A,B,C,D FM only
6083 Swivel mount bracket assembly, optional