SHATTERPRO™ PLUS
Motion-Sensitive
Acoustic Glassbreak
Sensor
Model number: 5885
• 24-hour acoustic glassbreak
application
• Motion-sensitive sensor "knows"
the area is occupied and
eliminates occupant generated
false alarms
• High-quality ShatterPro II
analysis combined with Sentrol
motion signal analysis
• Two-relay output for arming
either perimeter or interior loop
or both
• Can function as two sensors in
one package (PIR/Glassbreak)
The ShatterPro™ Plus is an acoustic glassbreak
sensor combined with a passive infrared motion
detector (PIR) for the purpose of eliminating occupant
generated false alarms. It will extend acoustic
glassbreak technology to occupied areas, allowing
these sensors to be armed while people or pets are
present. Simply put, when a person enters the field of
view of the motion detector the glassbreak sensor is
shunted during the period of occupancy. This elimi-
nates false alarms generated from normal noise levels
during occupied hours at work or at home. The
ShatterPro™ Plus can be wired into a 24-hour perim-
eter loop, free from concerns about false alarms
generated by a noisy environment.
The ShatterPro™ Plus utilizes all the features of the
ShatterPro II; excellent detection, false alarm immunity
in quiet environments, new test feature and the hand
clap end user feature. The PIR sensor utilizes Sentrol's
SureShot™ signal analysis and detection patterns.
ShatterPro™ Plus can also function as a combined
PIR/glassbreak with individual alarm outputs to the
panel for separate zoning. This allows for a separate
PIR alarm and separate glassbreak alarm.
![](/html/cd/cd8f/cd8f90c99248b426256cbd09033026096669e56c4912f2595bb368dbdff64303/bg2.png)
Sentrol ShatterPro™ Plus
Specifications:
Electrical
Operational voltage ........................................... 9 to 16 V DC
Current draw ................................ 15 mA typical; 30 mA max.
Alarm outputs ...... Normally closed, open 4 seconds on alarm
On resistance ................................................. 5 to 15 Ohms
Off resistance ..................................................... 20 MOhms
Maximum loop rating
(relay or tamper loop) ................................ 16 V DC, 50 mA
Fails safe and opens on power loss
Environmental
Lightning suppression ................... 400 watts for 1 msec pulse
Operating temperature ............ 0°F to 120°F (-18°C to +50°C)
RFI immunity ......................... 20 V/meter from 1 to 1000MHz
Humidity .................................... 10% to 90% noncondensing
LED Indicator
Glassbreak alarm ..............................................4 sec. solid red
Glassbreak test mode .................... 1 Hz blinking red/1 minute
Glassbreak latched ..................................................... solid red
Hand Clap Test ...................................................... 2 red blinks
PIR alarm ......................................................4 sec. solid green
PIR shunting Glassbreak ........................... 1 Hz blinking green
Lens Coverage ______________________________________
Accoustic Glassbreak Features
Housing material ........................... Flame retardant ABS plastic
Microphone ............................. Omni directional 360° electret
Sensitivity setting .................................................... Factory set
Range .............................. 15' (4.6 m) to farthest point of glass
15' (4.6 m) to farthest point of glass
Glass types detected
Plate glass ............................................... Up to
Tempered glass ...................................... Up to
Wired glass ............................................. Up to
Laminated glass ...................................... Up to
1
⁄4" (6.4 mm)
1
⁄4" (6.4 mm)
1
⁄4" (6.4 mm)
1
⁄4" (6.4 mm)
Mounting location ..... Ceiling or any wall except opposite wall
Minimum distance from glass ................................... 3.3' (1 m)
Minimum glass size ........................................................1' x 2'
Dimensions ................................................. 3.70" (9.40 cm) H
2.20" (5.59 cm) W
1.20" (3.05 cm) D
Color .................................................................... White/white
PIR Features
Pulse count ............................. Bi-directional, 1 zone (2 pulses)
with Motion Verification
Range .....................................................................................
1. Wide Angle (90°) ..................... 30' x 30' (9.14 m x 9.14 m)
2. 360° Ceiling .... 15' x 20' (4.57 m x 6.10 m) at 8' (2.44 m) high
16' x 30' (4.88 m x 9.14 m) at 12' (3.65 m) high
Ceiling mounting height up to 12' (3.65 m)
3. Single Spot ............................................. 40' (12.19 m) range
4. Vertical Barrier ........................................ 40' (12.19 m) range
5. Pet Alley (90°) ........................................... 30' (9.14 m) range
Top View
54°
38.4°
54°
38.4°
30'
91.1 m
360° Ceiling Mount
Wall Mount No Mask
20°
0°
20°
40'
12.2 m
2.1 m
(2.4 m)
Side View
7'
0
10'
20'
30'
6.1 m
9.1 m
40'
12.2 m
3.0 m
Note: Intruder must enter
capture zone in order to
8'
be detected. False alarm
sources, such as heaters,
Mounting Location Range __________________________
30' (9.2 m)
15' (4.6 m)
15' (4.6 m)
30' (9.2 m)
Dimensions _________________________________________
➝
1.20"
3.05cm
➝
2.20”
(5.6cm)
should be kept out of the
15' (4.6 m) x 20' (6.2 m)
capture zone
25' (7.2 m) diameter
coverage pattern
coverage pattern.
3.70”
(9.4cm)
➝
Ordering Information
Model Description Loop Type Electrical Configuration Listing
5885-W ShatterPro™ Plus Normally Closed N.C.
➝