To install the unit:
1. Remove the front cover (Figure 1) by gently prying the unit apart at the bottom. The front cover hinges at the top.
Figure 1. Exploded view
Front cover Back coverMasking
2. Remove the circuit board assembly by holding the pyro shield (Figure 1) and pulling it out of the back cover.
CAUTION You must be free of static electricity before
3. Mount the back cover to a ceiling, wall, or corner (see Mounting). For wall mounting, make sure the UP arrow is pointing up (Figure 2). Use the appropriate mounting and wiring knockouts.
Figure 2. Back Cover
Lens Pyro shield
plate
PET
ALLEY
WIDE
ANGLE
Masking kit
SINGLE
SPOT
V E R T
I C A L
PET
ALLEY
B A R R I E R
handling sensor circuit boards. Touch a grounded, bare metal surface before touching circuit boards or wear a grounding strap.
Ceiling mount mask sticker
6255/5885
Ceiling Mount Mask
Peel and stick to
groove side of lens.
Locate as shown.
4. Snap the circuit board assembly back onto the back cover by aligning the lower edge of the board with the circuit board guides and pressing it into place.
5. Strip back the outer jacket on the wiring cable to allow it to flex in the case. Make sure the cable is slack in the ceiling or wall to avoid stressing the wires at their connections. Connect the wires as shown in Figure 3. The unit should be connected to a UL listed power supply capable of providing 4 hours of standby power.
Figure 3. Wiring
-+
T erminals for power
9-16 VDC
PIR NC
Terminals for
PIR relay
PIR
COM
GBNCGB
COM
T erminals for
glassbreak relay
6. Choose a masking plate, if needed (see Zone patterns) and cut to match the lens. Insert the masking plate behind the lens on the front cover by pressing it over the three mounting pins (Figure 4). To correctly mount the Pet Alley mask (Figure
5), the lens must be removed from the front cover, rotated 180 degrees, and cut to fit. Once the front cover is installed, the masking plate will be held tight against the lens.
Figure 4. Inserting a masking plate
Align notch with dimple
Cut to match lens
Inside of front cover
Wall or ceiling mount knockouts
Corner mount knockouts
Wall or ceiling mount knockouts
Wiring knockouts
MADE IN U.S.A. 1-800-547-2556
UP
Wiring knockouts
Wall or ceiling mount knockouts
Corner mount knockouts
Wall or ceiling mount knockouts
Figure 5. Using the pet alley masking plate
Rotate
Cut to match lens
PET
lens 180°
ALLEY
Inside of front cover
ROTATE LENS
180
o
7. Replace the front cover and test the unit (see Testing the sensor).
ShatterPro Plus 5885
2
Installation Instructions
Mounting
For ceiling mount (Figure 6):
1. Mount unit in direct line of sight of windows to be protected. 2 . Sensor can be mounted as close as 3.3 feet (1 m) from glass
and up to 12 feet (3.7 m) from glass.
Note When ceiling mounted, be sure to use the the ceiling
Figure 6. Ceiling mount
For wall or corner mount (Figure 7):
1 . Do not aim sensor directly at window - install so PIR is
covering the area of room you expect to have occupied.
2 . Sensor can be mounted as close as 3.3 feet (1 m) from glass
and up to 12 feet (3.7 m) from glass.
mount mask sticker to reduce potential for false alarms.
Glassbreak
coverage
12 feet
12 feet
PIR coverage
To test the glassbreak only: Place Jumper J2 (Figure 8) on two pins so the motion sensing device is separated from glassbreak. Place the 5709C tester next to the microphone and put the unit into test mode by firing off the tester. The unit will be blinking red. Position yourself next to the glass you want to detect, select the appropriate glass type, and test the unit If drapes or blinds are present, test behind them (Figure 9). The LED will go solid red for 4 seconds if glass is within detection range.
Figure 8. Jumper locations
Microphone
Jumper J1 for LED latch
Jumper J2 for separate glassbreack and PIR
Figure 9. Testing positions
®
Figure 7. Wall and corner mount
Wall mount
Glassbreak coverage
PIR coverage
Corner mount
12 feet Glassbreak coverage
PIR coverage
12 feet
Sensor testing
Test the sensor to confirm that the field of view is set correctly and that the glassbreak detector will detect at the desired mounting location.
To test the field of view: Walk into the intended occupied area. The green LED should blink at 1 Hz for 1 minute. This means that the sensor has adjusted to a presence in the room and turned off the glassbreak alarm relay for 1 minute. It will turn the glassbreak on only after no movement has been detected for 1 minute. The LED will remain solid green for 4 seconds, indiating motion detection by the PIR.
T est and alarm LED indicators
Glassbreak alarm 4 seconds solid red Glassbreak test 1 Hz blinking red for 1 minute Glassbreak latched Solid red Hand clap test 2 red blinks PIR alarm 4 seconds solid green PIR shunting glassbreak 1 Hz blinking green for 1 minute
Note: Each time the glassbreak sensor alarms, it also goes into
test mode for 1 minute.
Hand clap test
The ShatterPro Plus can be checked by the installer or end-user while in normal mode by simply clapping hands loudly under the sensor. The LED will blink twice, but the sensor will not trip. This verifies visually that the microphone and circuit board are functioning.
When the ShatterPro Plus trips to an actual alarm condition, it will latch solid for 4 seconds, then start blinking for 1 minute. At the end of 1 minute, the LED will extinguish unless set for “LATCH-
ING LED”.
Latching LED
To use the latching LED, remove Jumper J1 (Figure 8) to latch the LED for glassbreak. When the unit alarms for glassbreak, the LED will remain solid red after exiting test mode. Reset the unit by removing power for at least 1 second.