GE Security 521CRXT, 528BXT-10PK Specsheet

E S L
P R O D U C T I N F O R M A T I O N B U L L E T I N
521 SERIES
Low Profile, Self-Diagnostic, Two­Wire, Photoelectric Smoke Detector
with CleanMe™
D
E
T
B
S
Y
I
L
U
A
N
D
U
LISTED
D
A
E
N
R
A
W
L
R
I
T
E
R
S
L
California State Fire Marshal Approved
C
F
O
S
E
I
R
A
O
B
T
O
A
R
• CleanMe™ remote maintenance reporting reduces false alarms
• Smart dual fixed/rate of rise heats work with photo chamber to catch fires faster
• Built-in drift compensation reduces false alarms
• Field replaceable optical chamber makes servicing a snap
• Small, low profile design blends in with any environment
TM
The ESL 521 Series self-diagnostic, two-wire smoke detectors are the industry's first conventional
direct-wire smoke detectors with analog features such as remote maintenance/trouble reporting (CleanMe™), drift compensation, and multi-criteria detection.
The 521 Series continually monitor their own sensi­tivity and operational status, and provide a visual and remote trouble condition if they drift out of the sensitiv­ity range or fail internal diagnostics. This meets NFPA 72 field sensitivity testing requirements without the need for external meters. The 521 has a unique feature enabling it to send a signal (CleanMe) to the ESL 505 module (sold separately) when it has drifted outside of its UL Listed sensitivity range or has failed its internal diagnostics test. The 505 is an interface module that will signal any panel via relays when the 521 is dirty. Several control panels have the CleanMe software built in, eliminating the need for the 505 module. When CleanMe is not desired, simply leave the switch on the 521 off and it will work as a normal two wire detector. CleanMe allows the installer time to schedule a service
call and avoid a false alarm.
Time between cleaning detectors is dramatically increased because of the 521's built-in drift compensa­tion. This feature, usually only available in analog systems, allows the detector to automatically adjust its sensitivity over time as it becomes dirty, increasing dust life.
And when the 521 has told you that cleaning is necessary, it's literally a snap with ESL's patented field replaceable optical chamber.
continued
521 Series ESL Photoelectric Smoke Detectors
The multi-criteria model 521XT photoelectric smoke detector/fixed rate of rise heat detector includes fast response algorithms for a quick response to both flaming and smoldering fires. Fast response algorithms allow the heat detectors to work intelligently together with the photo­electric smoke detector. As soon as the heat sensor detects a rapid rise in temperature, the sensitivity of the photoelec­tric sensor increases allowing it to detect smaller particles of combustion faster.
Architectural and Engineering Specifications
The ESL 521 Series photoelectric smoke detector is a low­profile, self-diagnostic , two-wire detector that monitors its own sensitivity and operational status. This detector meets NFPA 72 field sensitivity requirements without the need for external meters. Built-in drift compensation automatically adjusts the sensitivity as the detector gets dirty. Normal sensing occurs every 9 seconds. This rate doubles when a signal exceeding the alarm threshold value is sensed. Two additional successive signals above the threshold level will initiate an alarm.
See installation instructions for information about correct installation and maintenance.
The proprietary optical sensing chamber is field replaceable, allowing quick and easy cleaning and maintenance.
Dimensions:
Specifications: Product Data
Voltage..... Dip switch 1 “on” 6.5 – 33 VDC, polarity sensitive
Maximum ripple (pk to pk) ....................................10% (V
Typical average standby current (24V) .........................70µA
Typical alarm current (24V) ................ up to 60mA max, if not
Alarm Contacts .........................500mA @ 36 VDC (resistive)
Aux. Relay contacts............ 2A @ 30 VDC, 1 A @ 120 VAC
Sensitivity photoelectric .................. 3.1% + 0.50 – 1.00%
Operating temperature ............... 32°F to 100°F (0° to 37°C)
Operating humidity range ............ 0 to 95% Non-condensing
RFI Immunity ......................... 20 V/m minimum; 0-1000MHz
Color .................................................... White head and base
Field wiring size ................................................... 12-24 AWG
Detector packaging............................10 detectors per carton
Heat detector specifications .. Rate of rise 15°F/min and >
UL two-wire compatibility identifier....Dip switch 1 onS09A
Drift compensation adjustment........................... 1.0%/ft. max
Detector head dimensions...................... 5 (12 cm) diameter
Mounting dimensions..................... 4.75 (12.5 cm) diameter;
Reset time.................................................1 second minimum
Listings ........................................................ UL, ULC, CSFM
Dip switch 1 off 8.5 – 33 VDC, polarity sensitive
p - p
limited by control panel
105°F (8.3°C/min and > 40.6°C)
Fixed 135°F (57°C)
Dip switch 1 offS10A, S11A
2 (5 cm) height
0.3 (0.8 cm) height
)
2" (5cm) 5" (12cm)
Model No. Description
521B 2-wire, photoelectric, 6-24 VDC, UL listed 521BXT 2-wire, photoelectric, 6-24 VDC, multi-criteria algorithms, fixed/rate of rise heat, UL listed 521B-10PK 10 pack of 2-wire, photoelectric smoke detectors, 6-24 VDC with CleanMe not individually boxed 521BXT-10PK 10 pack of 2-wire, photoelectric smoke detectors, 6-24 VDC with fixed/rate of rise smart dual heat and
CleanMe not individually boxed 521CRXT 2-wire, photoelectric, 12-24 VDC, aux. relay, multi-criteria algorithms, fixed/rate of rise heat, UL listed 528B 2-wire, photoelectric, 6-24 VDC, ULC listed 528BXT 2-wire, photoelectric, 6-24 VDC, multi-criteria algorithms, fixed/rate of rise heat, ULC listed
Accessories
505 Module that interprets the 521s CleanMe signal for panel and can convert 2-wire 521 Series to 4-wire
inputs on panel 401 Test magnet in plastic shell for pole mounting SM-200 Smoke! in a Can® (canned smoke) for functional testing of smoke detectors 211 Replacement optical chambers (set of 10)
ESL
a product of sentrol
SENTROL
12345 SW Leveton Dr., Tualatin, OR 97062 Tel.: 503.692.4052 Fax: 503.691.7566 http://www.sentrol.com
U.S. & Canada: 800.547.2556 Technical Service: 800.648.7424 FaxBack: 1.800.483.2495
Sentrol reserves the right
to change specifications
without notice.
©2000 Sentrol
E-4054-st10K-0800
Loading...