Gewicht 0,152 Kg
kleinste Verpackungseinheit 10 St.
Safety-Transformer
• IEC 61558-1 and 2-6
• protection index IP 00
• prepared for class I / II equipment
• vacuum potted
• max. admissible ambient temp. 70°C
• 2 chamber safety-bobbin
• test voltage 4.000 V ac
• non-short-circuit-proof
• approval mark: VDE
weight 0,152 Kg
min. packaging unit 10 pieces
lieferbar ab Lager
available from stock
Primär V
primary V
230 V 1 – 5 6 V 7 - 9 8,3 V 630 mAT 387.06
230 V 1 – 5 8 V 7 - 9 11,1 V 500 mAT 387.08
230 V 1 – 5 9 V 7 - 9 12,5 V 400 mAT 387.09
230 V 1 – 5 12 V 7 - 9 16,7 V 315 mAT 387.12
230 V 1 – 5 15 V 7 - 9 20,9 V 250 mAT 387.15
230 V 1 – 5 18 V 7 - 9 25,0 V 200 mAT 387.18
230 V 1 – 5 24 V 7 - 9 33,4 V 160 mAT 387.24
230 V 1 - 5 30 V 7 - 9 41,7 V 125 mAT 387.30
abweichende Primär- oder Sekundärspannungen auf Anfrage
different primary or secondary voltage on request
GERTH Transformatorenbau GmbH; Seestr. 23, D - 14974 Ludwigsfelde
Gewicht 0,192 Kg
kleinste Verpackungseinheit 10 St.
Safety-Transformer
• IEC 61558-1 and 2-6
• protection index IP 00
• prepared for class I / II equipment
• vacuum potted
• max. admissible ambient temp. 70°C
• 2 chamber safety-bobbin
• test voltage 4.000 V ac
• non short-circuit-proof
• approval mark: VDE
weight 0,192 Kg
min. packaging unit 10 pieces
lieferbar ab Lager
available from stock
70°C/B
a
40,6
20
prim
15
34,2
27,5
sek
9
5
28,5
4
sek
7610
5
10
ø 0,8
Primär V
primary
V
Stift
pin
Sekundär V
secondary V
Stift
pin
Sek.
Sicherung
sec. cutoff
Leerlaufspannung
no-load voltage
Best.-Nr.
ref. no.
230 V 1 – 5 2 X 6 V 6-7 / 9-10 2 x 315 mAT 2 x 8,3 V 387.12.2
230 V 1 – 5 2 x 7,5 V 6-7 / 9-10 2 x 250 mAT 2 x 10,4 V 387.15.2
230 V 1 – 5 2 x 9 V 6-7 / 9-10 2 x 200 mAT 2 x 12,5 V 387.18.2
230 V 1 – 5 2 x 12 V 6-7 / 9-10 2 x 160 mAT 2 x 16,7 V 387.24.2
230 V 1 – 5 2 x 15 V 6-7 / 9-10 2 x 125 mAT 2 x 20,9 V 387.30.2
230 V 1 - 5 2 x 18 V 6-7 / 9-10 2 x 100 mAT 2 x 24,9 V 387.36.2
abweichende Primär- oder Sekundärspannungen auf Anfrage
different primary or secondary voltage on request
GERTH Transformatorenbau GmbH; Seestr. 23, D - 14974 Ludwigsfelde
Gewicht 0,152 Kg
kleinste Verpackungseinheit 10 St.
Safety-Transformer
• IEC 61558-1 and 2-6
• protection index IP 00
• prepared for class I / II equipment
• vacuum potted
• max. admissible ambient temp. 70°C
• 2 chamber safety-bobbin
• test voltage 4.000 V ac
• non-inherently short-circuit-proof
integrated thermal cutoff
•approval mark: VDE
weight 0,152 Kg
min. packaging unit 10 pieces
lieferbar ab Lager
available from stock
Primär V
primary V
230 V 1 – 5 6 V 7 - 9 8,3 V 387.06T
230 V 1 – 5 8 V 7 - 9 11,1 V 387.08T
230 V 1 – 5 9 V 7 - 9 12,5 V 387.09T
230 V 1 – 5 12 V 7 - 9 16,7 V 387.12T
230 V 1 – 5 15 V 7 - 9 20,9 V 387.15T
230 V 1 – 5 18 V 7 - 9 25,0 V 387.18T
230 V 1 – 5 24 V 7 - 9 33,4 V 387.24T
230 V 1 - 5 30 V 7 - 9 41,7 V 387.30T
abweichende Primär- oder Sekundärspannungen auf Anfrage
different primary or secondary voltage on request
GERTH Transformatorenbau GmbH; Seestr. 23, D - 14974 Ludwigsfelde
Gewicht 0,192 Kg
kleinste Verpackungseinheit 10 St.
Safety-Transformer
• IEC 61558-1 and 2-6
• protection index IP 00
• prepared for class I / II equipment
• vacuum potted
• max. admissible ambient temp. 70°C
• 2 chamber safety-bobbin
• test voltage 4.000 V ac
• non-inherently short-circuit-proof
integrated thermal cutoff
•approval mark: VDE
weight 0,192 Kg
min. packaging unit 10 pieces
lieferbar ab Lager
available from stock
Primär V
primary
V
230 V 1 – 5 2 X 6 V 6-7 / 9-10 2 x 8,3 V 387.12T2
230 V 1 – 5 2 x 7,5 V 6-7 / 9-10 2 x 10,4 V 387.15T2
230 V 1 – 5 2 x 9 V 6-7 / 9-10 2 x 12,5 V 387.18T2
230 V 1 – 5 2 x 12 V 6-7 / 9-10 2 x 16,7 V 387.24T2
230 V 1 – 5 2 x 15 V 6-7 / 9-10 2 x 20,9 V 387.30T2
230 V 1 - 5 2 x 18 V 6-7 / 9-10 2 x 24,9 V 387.36T2
abweichende Primär- oder Sekundärspannungen auf Anfrage
different primary or secondary voltage on request
Stift
pin
GERTH Transformatorenbau GmbH; Seestr. 23, D - 14974 Ludwigsfelde