GermanPool DB User Manual

Instantaneous Water Heater
即熱式電熱水器 即热式电热水器
DB
Printed in Germany WH-DB-M-10(1)
使用說明書
在使用之前請詳細閱讀 「使用說明書」及「保用條例」,並妥為保存。
在使用之前請詳細閱讀 「使用說明書」及「保用條例」,並妥為保存。
Please read these instructions and warranty information carefully before use and keep them handy for future reference.
ECO MAX
Assemble the instantaneous water heater as shown in the illustrations. Observe the information in the text.
Safety information
The instantaneous water heater must only be connected and started up by an authorized technician.
The statutory regulations of the respective country, as well as those of the local electricity and water suppliers must be adhered to.
The instantaneous water heater is an appliance of protection class I and must be connected to the protective earth conductor.
The unit must be durably connected to permanently installed lines.
In order to meet the current safety requirements, an all-pole disconnecting device must be present on the installation side. The contact gap must be at least 3 mm.
The instantaneous water heater is suitable for enclosed (pressurized) operation only.
The tap fittings must be permitted for operation with enclosed (pressurized) continuous-flow heaters.
The instantaneous water heater must only be connected to a cold-water pipe.
The instantaneous water heater is suitable for connection to DVGW-tested plastic pipes.
The instantaneous water heater must only be installed in a frost-free room.
Assembly
I. Unpacking / removing the housing cover
Unpack the appliance and check for transportation damage.
Dispose of the packaging and, where applicable, the old appliance, in an environmentally conscious manner.
II. Preparation for assembly
III. Wall-mounted assembly
The instantaneous water heater must be fitted securely to the wall. If required, secure the appliance using the lower adjusting screws.
The distance from the wall is variable. This allows you to compensate for any unevenness in the wall surface.
The sleeve must fit tightly round the connection cable. If the sleeve is damaged during installation, the holes must be sealed water-tight.
IV. Water supply
The flow-through heater must be vented. Open the warm water tap completely and allow to flow through for one minute.
V. Electric supply
The mains connection terminal can either be mounted above or below. At least 40 mm of the connecting cord’s insulating jacket must be clamped inside the appliance.
Prior to installation, the electric connecting cord must be disconnected from the mains voltage and the water supply cut off!
Only connect the electric supply after the water supply.
When making holes in the rear wall, only make the number of holes required for installation. If the appliance is reinstalled, any holes that are not used must be made watertight.
Live components must not be touched subsequent to installation.
This appliance must not be used by any person (including children) with limited physical, sensorial or mental abilities or failing experience and/or knowledge unless they are supervised by a person responsible for their safety or received instructions about how to use the appliance.Children should be supervised in order to make sure that they do not play with the appliance.
VI. Startup
At low water pipe pressure, check whether the MAX setting switches on even when water is drawn from several cold-water taps simultaneously. If not, remove the flow limiter (refer to additional information A).
Instruct the user with regard to the operation of the continuous-flow heater.
Separate the required language version from the rest of the operating instructions. This can be kept in the swingout control panel of the continuous-flow heater.
A. + B. Additional information
If the water pressure of the interior system is low, do not operate the instantaneous water heater at full power, but remove the flow limite (Fig. A).
Priority circuit for the combined operation of electric storage heaters (Fig. B)
Specifications
G 1/2” A
472
139
152
236
20
100
332
42
388
Rated power kW 18 21 24
Rated voltage 400 V3~ 400 V3~ 400 V3~
Economy setting ECO…
…1st stage kW 6 7 8
…2nd stage kW 12 14 16
Intensive setting MAX…
…1st stage kW 9 10.5 12
…2nd stage kW 18 21 24
Switch-on point…
…1st stage I/min 4.0 4.5 5.0
…2nd stage I/min 5.0 5.8 6.6
Mixed water at rated power… I/min
…approx. 38 °C 9.9 11.6 13.2
…approx. 50 °C (supply temperature 12 °C) 6.8 7.9 9.1
Minimum flow pressure of appliance*…
…with flow limiter MPa (bar) 0,07 (0,7) 0,08 (0,8) 0,09 (0,9)
…without flow limiter MPa (bar) 0,04 (0,4) 0,05 (0,5) 0,06 (0,6)
Operative range in waters of specific electric resistance at 15 °C Ωcm
Rated pressure MPa (bar)] 1 (10) 1 (10) 1 (10)
Maximum permissible supply temperature °C 20 20 20
* Plus any pressure loss at the tap mixer
≥ 1300 ≥ 1300 ≥ 1300
Special accessories
UDB Pipe set: When using the instantaneous water heater as a built-under appliance.
ADB Mounting set: For surface-mount installation.
請依據後圖所示安裝熱水器,請務必注意相關文字說明。
安全注意事項
·此即熱式電熱水器只允許專業人士進行安裝和調 試。
·必須遵守當地國家有關法律規定以及當地電力供 應商及水務署的各有關規定。
·此即熱式電熱水器屬I類電器,所以必須接上地 線。
·必須將機器接駁在固定之管線系統上。
·為達到有關安全規定起見,安裝端須備有全極的 切斷裝置,觸頭間隙須至少 3 釐米大。
·此熱水器僅適用於封閉式(耐壓式)工作方式。
·接水管的配件必須有許可證,以便被允許可以接 上封閉式(耐壓式)即熱式電熱水器。
·本即熱式電熱水器只可接在冷水管上。
·即熱式電熱水器上可接 DVGW(德國煤氣與供水 專業人士協會)檢驗過的塑膠管。
·即熱式電熱水器只可安裝在不霜凍的房間內。
安 裝
Ⅰ. 拆開包裝,拿開保護罩
·將機器從包裝中拿出來,檢查是否有運輸損失。
·包裝材料應按環保標準去處理(若有不要的舊機 器,也應按環保標準去處理)。
Ⅱ. 安裝前的準備性工作
Ⅲ. 安裝在牆壁上
·即熱式電熱水器應在牆上固定好:若需要,可固 定在下方調節螺絲上。
·熱水器與牆壁間的間隙大小可調整,牆壁上若 有凹凸不平之處可進行調整使機器保持平坦的位 置。
·套管必須緊密地圍繞著接駁電纜。在安裝熱水器 時,如果損壞到此套管,則須把破洞密封好,使 其不透水。
Ⅳ. 接駁供水管道
·安裝前,須切斷接駁電纜的電源,鎖緊供水管。
·供水管接駁好後才可接駁電纜。
·熱水器背面上只有鑽安裝所需的孔洞,若以後需 要另外重新安裝,則須將用不著的孔洞填補且密 封,不讓其漏水。
·安裝好後,帶電部分應是用手觸摸不到的位置。
·必須排盡即熱式電熱水器中之空氣。排氣時先完 全開啟熱水水喉,以讓水流流貫過熱水器,此過 程須持續一分鐘左右。
Ⅴ. 接上接駁電纜
·主電源接駁可安裝在上方或下方。接駁電纜的絕 緣層應進入機器內部至少 40mm 深。
Ⅵ. 啟動
·在水管低水壓且多幾個冷水喉同時開啟的情況 下,請您檢查機器的增強加熱段“MAX”是否會 自動啟動。若否,請您拆除流量限制器(參見附 加說明 A)。
·請向用戶說明即熱式電熱水器的操作方法。
·請將所需的使用說明從使用說明書中撕下來,可 保存在熱水器可翻開的操作面蓋內。
附加說明
·如果建築內水管水壓太低而造成熱水器不能以全 功率工作,則應拆除流量限制器(圖 A)。
·與保溫加熱器並列使用時,此即熱式電熱水器應 優先配線(圖 B)。
技術資料
G 1/2” A
472
139
152
236
20
100
332
42
388
額定功率 [ 千瓦 ]
額定電壓
節能位置“ECO”…
…第一段 [ 千瓦 ]
…第二段 [ 千瓦 ]
增加加熱“ECO”…
…第一段 [ 千瓦 ]
…第二段 [ 千瓦 ]
啟動點…
…第一段 [ 公升/分鐘 ]
…第二段 [ 公升/分鐘 ]
在額定功率情況下的混合水量 [ 公升/分 鐘 ]
…約 38℃
…約 50℃(自來水溫 12℃)
機器上最少流壓 *…
…配流量限制器時 [ MPa(巴)]
…不配流量限制器時 [ MPa(巴)]
不同水質應用範圍在 15℃ 環境下的比電 阻 [Ωcm]
額定壓力 [MPa(巴)]
18 21 24
400 V3~ 400 V3~ 400 V3~
6 7 8
12 14 16
9 10.5 12
18 21 24
4.0 4.5 5.0
5.0 5.8 6.6
9.9 11.6 13.2
6.8 7.9 9.1
0.07 (0.7) 0.08 (0.8) 0.09 (0.9)
0.04 (0.4) 0.05 (0.5) 0.06 (0.6)
≥ 1300 ≥ 1300 ≥ 1300
1 (10) 1 (10) 1 (10)
最大供水溫度 [℃]
* 此處還需將混合水喉內的降壓算進去。
20 20 20
專用附件
·水管組合 UDB 型:用於即熱式電熱水器安 裝在工作臺底下時。
·ADB 安裝配件:用於表面安裝。
Loading...