Operating Instructions:
Please read these instructions carefully before using the appliance!
3. Technical specifications
TypeCRX 9
Capacity0.2 l
Pressure-type, rating pressure0.6 MPa (6 bar)
Heating systemTubular heater
Nominal rating
Rated voltage (50 Hz)1N / PE ~
Rated current at 220 – 240 V36 – 40 A
Min. required conductor cross-section3 × 6.0 mm
Factory preset flow reducer5.0 l/min
Increase of temperature ∆t at present flow23 K
Hot water temperature at 20 °C inlet temp. 43 °C
Switch-on flow rate2 l/min
Temperature presetting35 – 55 °C
Useful for cold water up to30 °C
Water connection½“ B.S.P. surface-mounted or flush-mounted
Net weight and dimensions (H × W × D)2.2 kg / 33 × 21 × 9 cm
Protection class and type of protection to VDE1 / IP25
Safety marksee type plate
3
8.0 – 9.6 kW
2
CRX 9
4. Operation instructions
Safety instructions for closed-outlet water heaters:
• Installation, initial operation and maintenance of this appliance must only be conducted by an authorised professional, who will then be responsible for adherence to applicable standards and installation regulations. We assume
no liability for any damages caused by failure to observe these instructions.
• Do not use the appliance until it has been correctly installed and unless it is in perfect working order.
• The appliance is only suitable for domestic use and similar applications inside closed, frost-free rooms, and must only
be used to heat incoming water from mains supply.
• The appliance must never be exposed to frost.
• The appliance must be earthed at all times.
• The maximum water pressure must not exceed the value on the label.
• Before commissioning for the first time and each time the appliance is emptied (e.g. due to work on the plumbing
system, if there is a risk of freezing or in case of maintenance), the appliance must be vented correctly in accordance
with the instructions in this manual.
• Do not remove the front cover under any circumstances before switching off the mains electrical supply to the unit.
• Never make technical modifications, either to the appliance itself or the electrical leads and water pipes.
• Pay attention to the fact that water temperatures in excess of approx. 43 °C are perceived as hot, especially by chil-
dren, and may cause a feeling of burning. Please note that the fittings and taps may be very hot when the appliance
has been in use for some time.
• Water inlet temperature must not exceed 30 °C.
• In case of malfunction, disconnect the fuses immediately. In case of leaks, cut off the cold water supply instantly.
Repairs must only be carried out by the customer service department or an authorised professional.
• This appliance must not be used by any person (including children) with limited physical, sensorial or mental abilities
or failing experience and/or knowledge unless they are supervised by a person responsible for their safety or received
instructions about how to use the appliance.Children should be supervised in order to make sure that they do not
play with the appliance.
12
Description of appliance
3
The appliance is a closed-outlet electronically controlled instantaneous heater for
decentral water heating at one or two taps situated in close proximity to one another,
e.g. wash basin or shower. Technical specifications → see page 3!
4
Use
The instantaneous water heater heats the water to the required temperature directly as
5
–
+
it streams through. The heater switches on automatically when the threshold flow rate
is exceeded. The „Power“ indicator (2) lights up when the heater is switched on. The
„Pressure“ indicator (3) lights up when the flow rate is too low.
The power is automatically adjusted by the electronics in line with the water flow rate
in order to obtain the set temperature and keep it virtually constant. The required temperature can be set to within one degree between 35 °C and 55 °C via the two buttons
(5) and can be read off on the digital display (4).
If the full power of the instantaneous heater is not sufficient to heat the water to the
required temperature, this is indicated by the flashing „Power“ indicator (2). The temperature can be restored by reducing the hot water flow rate at the tap.
4
CRX 9
4. Operation instructions
If the heater supplies two outlets, the water from the unit will be shared between the outlets. You should therefore only
use one outlet at a time in order to obtain a sufficient flow.
At high feed temperatures, the power is automatically switched off by the electronics in order to avoid producing excessively hot water. This is indicated by the „Overheat“ lamp (1).
Venting
To prevent damage to the appliance, the instantaneous water heater must be vented before using it for the first time.
Each time it is emptied (e.g. after work on the plumbing system, if there is a risk of frost or following repair work), the
appliance must be re-vented before it is used again.
1. Disconnect appliance from the mains by removing the fuses.
2. Next, open and close the hot water tap valve several times until no more air emerges from the pipe and all air has
been eliminated from the water heater (approx. 1 minute).
3. Only then re-connect the power supply to the unit.
Save energy
Set precisely the required temperature on the appliance and only open the hot water tap. If the water is too hot, set a
lower temperature on the appliance instead of adding cold water. If you add cold water, the heated water is cooled
again and valuable energy will be lost. Moreover, the cold water added in the fitting cannot be controlled by the electronics and a constant temperature can no longer be guaranteed.
to ensure proper functioning and operational safety at all times.
5
CRX 9
4. Operation instructions
10a
Cleaning the fine filter (flush-mounted)
The fine filter is located in the water connection (10) and
II
should be examined by an expert and cleaned if necessary
not only when operation of the appliance deteriorates, but
also in conjunction with regular servicing.
1. Disconnect the instantaneous water heater by means of
the house fuses and close the shut-off valve (10a) in the
cold water connection piece (position II) or shut-off the
I
mains supply.
2. Unscrew the screw plug (10b) from the cold water connection piece and take out the strainer (10c).
Attention: Residual water comes out!
3. The strainer can be cleaned or re placed.
4. After fixtur of the strainer tighten the screw plug.
5. Slowly open the shut-off valve in the cold water connection piece (position I).
6. Vent the unit by carefully opening and closing the affiliated warm water tap valve several times until air no
longer emerges from the pipe.
10c
10b
10d
Cleaning the fine filter (surface-mounted)
The fine filter is located in the water connection (10) and
should be examined by an expert and cleaned if necessary
not only when operation of the appliance deteriorates, but
also in conjunction with regular servicing.
1. Disconnect the instantaneous water heater by means of
the house fuses and shut-off the main water supply.
2. Unscrew the cold water inlet connection of the unit and
take out the strainer (10 d) of the connection piece.
Attention: Residual water comes out!
3. The strainer can be cleaned or replaced.
4. After fixture of the strainer remount the water connection
of the unit.
5. Carefully open the main water supply.
6. Vent the unit by carefully opening and closing the affiliated warm water tap valve several times until air no
longer emerges from the pipe.
6
CRX 9
5. Customer service
If you experience a malfunction, please try to rectify the fault your self first with the help of this table. If a
fault in your appliance cannot be rectified with the aid of this table, please contact German Pool who will
either assist you directly or put you in touch with a customer service contract partner in your area.
Always specify the appliance model and serial number, please!
ProblemPossible CauseSolution
LED remains off, water remains coldCircuit breaker trippedHave the fault rectified and reset
The pilot lamp „Power“ lights,
water remains cold
The pilot lamp „Pressure“ lights,
water remains cold
Water flows lower as expected
The hot water is not hot enough
Temperature and pressure varyCold water is being added
Heating element or electronics faulty
Safety thermal cut-out tripped
Flow rate too low
Depends on the heater Check technical specifications
Outlet fitting dirty or calcifiedClean tap fitting or shower head
Filter dirty or calcifiedClean or renew the filter
Tap not suitableUse suitable shower head or aerator
Electronic boardReset fuse
Flow rate is too high (winter?)Reduce the water flow slightly
Heating element defectContact customer service
Reset fuse, water remains cold contact
customer service
Reset. In case of repeated trips contact
customer service
Increase flow pressure
Clean tap fitting or shower head
Only hot water can be delivered to within
one degree
If you cannot rectify the fault with the aid of this table, please contact your distributer or German Pool
Customer Service – China Headquarters.
Repairs may only be carried out by authorized professionals!
We can either give you the name and address of an authorised customer service company or repair the
heater ourselves. In the latter case, please send in the heater (at your cost and risk) with details of the
problem and a copy of the sales invoice.
7
CRX 9
6. Installation
If you install the instantaneous water heater CRX 9 instead of a conventional instantaneous water heater, there is generally no need to drill holes for the wall holder. In this case, you only need to screw in the double nipples as described in 2.
and to secure the wall bracket.
Installing the wall bracket (flush-mounted):
1. Thoroughly rinse the water supply pipes before installation to remove soiling from the pipes.
2. Using a 12 mm hexagon socket screw key, screw the screw-in nipple into
the wall connector. After tightening, the double nipple must protrude by
12 mm.
3. Carefully seal the hot water connection pipe with a little P.T.F.E. Tape and
screwed it into the wall connection. Mount the cold water connector piece
including the 1/2“ seal.
4. Hold the unit on the wall and align it so that the water connectors of the
unit fit over the connections of the wall. Mark the drill holes and drill them
using a 6 mm drill.
5. Mount the unit to the wall and connect the water supply of the unit,
together with the 3/8“ seals.
6. Open the water supply line to the unit and slowly open the shut-off valve
in the cold water connection piece (10 a) (Pos.I). Check all connections for
leaks.
7. Next, open and close the hot water tapping valve several times until no
more air emerges from the line and all air has been eliminated from the
instantaneous water heater.
8
CRX 9
6. Installation
Installing the wall bracket (surface-mounted):
1. Thoroughly rinse the water supply pipes before installation to remove soiling from the pipes.
2. Screw the 1/2“ screw in nipple and the 1/2“ seal into the 1/2“ union nuts of
the hot-water connector.
3. The 1/2“ cap of the side outlets of the coldwater connectors must be
removed and screwed onto the open end of the screw-in nipple.
4. Mount the fine filter into the cold water connection piece (10 d).
5. The hot-water and cold-water connectors must then be screwed into the
3/8“ union nut of the appliance and delivery pipe, together with the 3/8“
seals.
6. Mark the drill holes and drill them using a 6 mm drill. Mount the unit to the
wall and connect the water supply of the unit.
7. The holes in the housing of the unit required for the pipes must then be
broken out of the housing with the aid of a blunt implement.
8. Open the water supply line to the unit and slowly open the shut-off valve in
the cold water connection piece (drawing 10 a on page 6).
Check all connections for leaks.
9. Next, open and close the hot water tapping valve several times until no
more air emerges from the line and all air has been eliminated from the
instantaneous water heater.
10d
9
CRX 9
6. Installation
Installation instructions for the authorized technician
• The installation site must be free from frost at all times.
• The appliance complies with protection type IP25 and may be installed in zone 1 acc. IEC
• In order to avoid thermal losses, the distance between the heater and the tapping point
should be as small as possible (< 2 m).
• Best performance is guaranteed at a flow pressure of ≥ 3 bar, avoiding pressures exceeding
6 bar.
• Material of water pipes for tubular heater types: cold water: steel or copper, hot water:
copper
Important notice!
A backflow preventer (
is already provided inside
the brass connection of
the hot water outlet.
It must NOT be fitted in
the cold inlet line before
the appliance!
)
10
CRX 9
6. Installation
Installing the appliance:
1. Rinse water supply pipes thoroughly and turn off for installation.
2. Remove the front cover by unscrewing the locking screw
behind the small lid.
3. Locate and break out the required holes and cable inlets.
Mark the drilling holes with the appliance and drill them
with a 6 mm bit.
4. Fit the rubber grommet supplied and insert the connecting
lead. The lead must be secured with the cable clamp when
using a flexible power cord.
5. Screw the appliance into position using the enclosed raw
plugs and screws.
6. Install the appliance as shown in the principal examples
above. The inlet and outlet are marked with arrows.
7. The water connections are designed for surface-mounted
or flush-mounted installation. They must be carefully
sealed with a little P.T.F.E. Tape when screwed into the wall
connections.
8. The front cover must be neatly broken at the designated
points when installed on the wall.
11
CRX 9
6. Installation
10 a
II
Closed
flush-mounted
installation
9. Turn on the water supply and slowly open the shutoff valve (10 a) in the
cold-water connection (position I) if necessary. Check all connections
for leaks.
10. Next, open and close the hot water tap several times until no more air
emerges from the line and all air has been eliminated from the heater.
I
12