GE P&W SG Series User Manual

Fact Sheet
Find a contact near you by visiting www.gewater.com and clicking on “Contact Us” .
* Trademark of General Electric Company; may be registered in one or more countries.
©2013, General Electric Company. All rights reserved.
Membrane
S-Series, Thin-film membrane (TFM*)
Model
Average permeate flow gpd (m3/day)
1,2
Average NaCl
rejection
1,2
Minimum
NaCl
rejection
1,2
SG2540F30
590 (2.2)
98.5%
97%
SG2540F50
370 (1.4)
98.5%
97%
SG4040C30
2,200 (8.3)
98.5%
97%
SG8040F30
8,400 (31.8)
98.5%
97%
Model
Spacer
mil (mm)
Active area
ft2 (m2)
Outer wrap
Part
number
SG2540F30
30 (0.76)
27 (2.5)
Fiberglass
1207546
SG2540F50
50 (1.27)
17 (1.6)
Fiberglass
1207547
SG4040C30
30 (0.76)
100 (9.3)
Cage
1207577
SG8040F30
30 (0.76)
380 (35.3)
Fiberglass
1207614
Model1
Dimensions, inches (cm)
Boxed
A
B2
C3
Weight
lbs (kg)
SG2540F30
40.0
(101.6)
0.75
(1.90) OD
2.4
(6.1)
4
(1.8)
SG2540F50
40.0
(101.6)
0.75
(1.90) OD
2.4
(6.1)
4
(1.8)
SG4040F50
40.0
(101.6)
0.625
(1.59)
3.9
(9.9)
9
(4.1)
SG4040C30
40.0
(101.6)
0.625
(1.59)
3.9
(9.9)
9
(4.1)
SG8040F30
40.0
(101.6)
1.125 (2.86)
7.9
(20.1)
29
(13.2)
Typical Operating Flux
5 – 20 GFD (8 – 34 LMH)
Maximum Operating Pressure
600psi (4,137kPa) if T < 95°F (35°C) 435psi (3,000kPa) if T > 95°F (35°C)
Maximum Temperature
Continuous Operation: 122°F (50°C) Clean-In-Place (CIP): 122°F (50°C)
pH Range
Optimum Rejection: 5.5-7.0, Continuous Operation: 2.0-10.0, Clean-In-Place (CIP): 1.0-10.5
Maximum Pressure Drop
Over an element 15psi (103kPa) per housing: 60psi (414kPa)
Chlorine Tolerance
500+ ppm hours, dechlorination recommended
Feedwater
NTU < 1 SDI < 5
SG Series

Industrial Brackish Water RO Elements

The S-Series family of proprietary thin-film reverse osmosis membrane elements is characterized by high sodium chloride rejection and a smooth, foul­ing-resistant membrane surface.
SG Brackish Water Elements are used for brackish water desalination and process stream concentra­tion.
The SG elements feature either a patented cage or fiberglass outer wrap and 30mil or 50mil spacer.
Table 1: Element Specification
Figure 1a: Element Dimensions Diagram (Female)
Table 2: Dimensions and Weight
1
Average salt rejection after 24 hours operation.
Individual flow rate may vary ±25%.
2
Testing conditions: 2,000ppm NaCl solution at 225psi (1,551kPa) operating pres-
sure, 77°F (25°C), pH 6.5 and 15% recovery.
1
These elements are dried then bagged before shipping.
2
Internal diameter unless specified OD (outside diameter).
3
The element diameter (dimension C) is designed for optimum performance in GE pressure vessels. Other pressure vessel dimension and tolerance may result in excessive bypass and loss of capacity
Table 3: Operating and CIP Parameters
Loading...