Membrane
P-Series, Polyethersulfone
Model
Spacer mil
(mm)
Active area
ft2 (m2)
Outer wrap
Part
number
PW2540C30
30 (0.76)
16 (1.5)
Cage
1207350
PW2540F30
30 (0.76)
25 (2.3)
Fiberglass
1207352
PW2540F50
50 (1.27)
17 (1.6)
Fiberglass
1207351
PW4025C
50 (1.27)
50 (4.6)
Cage
1207367
PW4025T
50 (1.27)
50 (4.6)
Tape
1207369
PW4040C30
30 (0.76)
91 (8.4)
Cage
1207372
PW4040C50
50 (1.27)
62 (5.8)
Cage
1207371
PW4040F30
30 (0.76)
85 (7.9)
Fiberglass
3050051
PW8040C50
50 (1.27)
264 (24.5)
Cage
1207399
PW8040F30
30 (0.76)
354 (39.2)
Fiberglass
1207404
PW8040F50
50 (1.27)
279 (25.9)
Fiberglass
1207403
PW8340C50
50 (1.27)
290 (27)
Cage
1223936
Model1
Dimensions, inches (cm)
Boxed
A
B2
C3
Weight lbs (kg)
PW2540
40.0
(101.6)
0.75
(1.9) OD
2.4
(6.1)
4
(1.8)
PW4025
25.0
(63.5)
0.625 (1.59)
3.9
(9.9) 5 (2.3)
PW4040C
38.75 (98.4)
0.625 (16)
3.9
(9.8)
9
(4.1)
PW4040F
40.0
(101.6)
0.75
(1.90) OD
3.9
(9.9) 8 (3.5)
PW8040
40.0
(101.6)
1.125
(2.86)
7.9
(20.1)
29
(13.2)
PW8340
40.0
(101.6)
1.138
(2.89)
8.3
(21.1)
42
(19.1)
Typical Operating Pressure
80-135 psig (555 – 931 kPa)
Typical Operating Flux
10-25GFD (15-40LMH)
Maximum Operating Pressure
200 psig (1,379 kPa)
Maximum Temperature
Continuous operation: 122°F (50°C) Clean In Place (CIP): 122°F (50°C)
pH Range
Continuous operation: 4.0-11.0, Clean In Place (CIP): 2.0-11.5
Maximum Pressure Drop
Over an element: 12 psig (83 kPa) Per housing: 50 psig (345 kPa)
Chlorine Tolerance
5,000+ ppm-days
PW Series

Industrial Ultrafiltration – Post treatment of RO and NF

The P-Series family of polyethersulfone ultrafiltra­tion membrane elements are characterized by a 10,000 molecular weight cut-off and greater than 96% rejection of Cytochrome-C (13,300 MW pro­tein). PW Elements are used for pretreatment of process water, post treatment of ultrapure water and for the removal of organics.
Table 1: Element Specification
Figure 2: Element Dimensions Diagram – Male
Table 2: Dimensions and Weight
Figure 1: Element Dimensions Diagram – Female
1
These elements are bagged dry before shipping.
2
Internal diameter unless specified OD (outside diameter).
3
The element diameter (dimension C) is designed for optimum performance in GE pressure vessels. Other pressure vessel dimension and tolerance may result in excessive bypass and loss of capacity.
Table 4: Operating and CIP parameters