Membrane
P-Series, Polyethersulfone
Model
Spacer
mil (mm)
Active area
ft2 (m2)
Outer wrap
Part
number
PT8040C50
50 (1.27)
255 (23.7)
Cage
1240574
PT8040F30
30 (0.76)
350 (32.5)
Fiberglass
1229772
Model1
Dimensions, inches (cm)
Boxed
A
B2
C3
Weight
lbs (kg)
PT8040
40.0
(101.6)
1.125 (2.86)
7.9
(20.1)
29
(13.2)
Typical Operating Flux
5 – 20 GFD (8 – 34 LMH)
Maximum Operating Pressure
200psi (1,379kPa)
Maximum Temperature
Continuous Operation: 122°F (50°C) Clean-In-Place (CIP): 122°C (50°C)
pH range
Continuous Operation: 2.0-10.0, Clean-In-Place (CIP): 1.0-11.5
Maximum Pressure Drop
Over an element: 15psi (103kPa) Per housing: 60psi (414kPa)
Chlorine Tolerance
5,000 ppm days
PT Series

Industrial Ultrafiltration Elements – PES 5,000 MWCO

The PT family of polyethersulfone ultrafiltration membrane elements is characterized by a 5,000 molecular weight cut-off.
Table 1: Element Specification
Figure 1: Element Dimensions Diagram (Female)
Table 2: Dimensions and Weight
1
These elements are bagged dry before shipping.
2
Internal diameter unless specified OD (outside diameter).
3
The element diameter (dimension C) is designed for optimum performance in GE Water & Process Technologies pressure vessels. Other pressure vessel dimension and tolerance may result in excessive bypass and loss of capacity.
Table 3: Operating and CIP parameters